HomeMy WebLinkAboutADP 2023-05-17 Agenda.pdf
City of Maple Ridge
ADVISORY DESIGN PANEL
AGENDA – REGULAR MEETING
Wednesday, May 17, 2023 at 4:00 pm
Meeting Access Information
Advisory Design Panel (ADP) meetings are held virtually viz Zoom Teleconference. Members of the ADP and the
public are asked to join the meeting remotely using the following access information:
Join the meeting from your computer, tablet or smartphone
https://mapleridge-ca.zoom.us/j/84517294965
Or join the meeting using your phone
Dial: 1-778-907-2071 Meeting ID: 845 1729 4965
1. CALL TO ORDER
2. APPROVAL OF THE AGENDA
3. ADOPTION OF MINUTES – April 12, 2023
4. NEW AND UNFINISHED BUSINESS
5. QUESTION PERIOD
6. PROJECTS
6.1 Development Permit No: 2022-034-DP 4:15 PM
Applicant: Kunwar Bir Singh
Project Architect: Kasian Architecture, Interior Design and
Planning
Project Landscape Architect: PMG Landscape Architects
Proposal: To construct a townhouse
development with 52 market strata
dwelling units
Location: 11926, 11936, 11946, and 11956
236 Street, and 23638 Dewdney
Trunk Road
File Manager: Daniel Rajasooriar
6.2 Development Permit No: 2021-579-RZ 5:00 PM
Applicant: Geoff Lawlor Architect AIBC
Project Architect Geoff Lawlor
Project Landscape Architect: Clark Kavolina
Proposal: An application has been received to
rezone the subject property from M-
1 (Service Industrial) to RM-1 (Low
Density Townhouse Residential) and
R-2 (Single Detached (Medium
Advisory Design Panel
May 17, 2023
Page 2 of 2
Density) Urban Residential) in order
to permit a future subdivision of
approximately two single-family lots
and the future construction of
approximately 16 townhouse units
on a third lot
Location: 23682 Dewdney Trunk Road
File Manager: April Crockett
10-minute break
6.3 Development Permit No: 2020-065-RZ 5:55 PM
Applicant: Shoghig Tutunjian
Project Architect Studio One Architects – Shoghig Tutunjian
Project Landscape Architect: M2 Landscape Architects
Proposal: 6-storey mixed-use building with
commercial at grade and 59 units
Location: 22323, 22335, and 22345 Callaghan Avenue
File Manager: Daniel Rajasooriar
6.4 Development Permit No: 2019-051-DP 6:40 PM
Applicant: Ruchir Dhall
Project Architect Ruchir Dhall
Project Landscape Architect: Ruchir Dhall
Proposal: 18-unit townhouse development
under the RM-1 Zone
Location: 11405 236 Street
File Manager: Rosario Alvarado
7. CORRESPONDENCE
8. ADJOURNMENT
Next Meeting: June 21, 2023
Agenda Items Submission Deadline: May 17, 2023
QUESTION PERIOD
Question Period provides the public with the opportunity to ask questions or make comments on subjects
that are of concern to them. Each person will be given 2 minutes to speak.
Up to ten minutes in total is allotted for Question Period.
City of Maple Ridge
Advisory Design Panel Meeting Minutes
April 12, 2023
The Minutes of the Regular Meeting of the Maple Ridge Advisory Design Panel (ADP) held via Zoom
teleconference on Wednesday, April 12, 2023 at 4:00 pm.
PANEL MEMBERS PRESENT
Jose Gonzalez, Chair Landscape Architect BCSLA
Sang Kim, Vice Chair Architect AIBC
Jaswinder Gabri Architect AIBC
Lindsey Salter Architect AIBC
Niall McGarvey Landscape Architect BCSLA
STAFF MEMBERS PRESENT
Wendy Cooper Staff Liaison, Planner 2
Arsh Dhillon Committee Clerk
PANEL MEMBERS ABSENT
1.CALL TO ORDER – 4:03 p.m.
2.APPROVAL OF AGENDA
R/2023-ADP-009
It was moved and seconded
That the agenda for the April 12, 2023 Advisory Design Panel Regular Meeting be approved
as circulated.
CARRIED UNANIMOUSLY
3.ADOPTION OF MINUTES
R/2023-ADP-010
It was moved and seconded
That the minutes for the March 22, 2023 Advisory Design Panel meeting be adopted.
CARRIED UNANIMOUSLY
4.NEW AND UNFINISHED BUSINESS – NIL
5.QUESTION PERIOD – NIL
6.PROJECTS
3.0
Advisory Design Panel Minutes
April 12, 2023
Page 2 of 4
6.1. Development Permit No: 2021-128-DP / 20234 Lorne Avenue
The Chair welcomed the project team to the meeting and introduced the members of the ADP.
The Staff Liaison provided a brief overview of the project. The project team presented the
development plans and answered questions from the Panel.
R/2023-ADP-011
It was moved and seconded
That the following concerns be addressed and digital versions of revised drawings & memo be
submitted to Planning staff; and further the Planning staff forward this on to the Advisory design
Panel for information.
Architectural Comments:
• Suggestion for operable window height to ensure it meets building code height
• Opportunity to give buildings more character, consider Hammond Heritage Guidelines
for the building character
• Ensure minimum width required for double car garage has been met
• Further façade and roofline articulation should be considered for neighborhood
integration
• Consider opening the south-west corner of the garage for daylight infiltration in the
central courtyard
Landscape Comments:
• Suggest introducing pavement accent bands in the courtyard
• Suggest widening access to courtyard between Unit C and Unit B
• Consider introducing barbeque and picnic amenities in the south-west courtyard to
accommodate bigger groups
• Consider providing bike racks
• Consider not using concrete in critical root zone
CARRIED UNAMINOUSLY
6.2. Development Permit No: 2021-389-RZ / 11619, 11631, and 11639 Adair Street
The Chair welcomed the project team to the meeting and introduced the members of the ADP.
The Staff Liaison provided a brief overview of the project. The project team presented the
development plans and answered questions from the Panel.
R/2023-ADP-012
It was moved and seconded
That the following concerns be addressed and digital versions of revised drawings & memo be
submitted to Planning staff; and further the Planning staff forward this on to the Advisory design
Panel for information.
Architectural Comments:
• Provide rendering illustrating landscape and architectural
• Consider detailing to mitigate cold strikes at foundation footing and second floor
overhang
• Consider detailing between Unit demising walls and floor slabs to maintain STC rating
of 57, to mitigate potential for noise transfer
Advisory Design Panel Minutes
April 12, 2023
Page 3 of 4
• Consider similar design language between upper flat roof and lower skirt roofs
• Ensure correct roofing membrane is applied to flat roofing areas, ensure adequate
slope is included to drain roof to gutter
• Consider reconfiguring entrances for Unit A and B to ensure visibility from the street
• Consider using uniform colour palette for all buildings, suggest toning down orange
colour
Landscape Comments:
• Suggest extending material treatment from south façade around the building
• Suggest introducing horizontal trim to break the façade material between levels
• Suggest friendlier configuration for front yard fencing along Adair Street. Suggest
deleting fencing in front of car parking, consider providing landscaping fencing with
higher degree of transparency.
• Rain water harvesting for garden use encouraged
• Include rendered colour plans for clarity
• Consider reconfiguring circular paver design for south building driveway
CARRIED UNAMINOUSLY
6.3. Development Permit No: 2021-471-RZ / 22582, 22588, 22596, 22606, and 22610
121 Avenue
The Chair welcomed the project team to the meeting and introduced the members of the ADP.
The Staff Liaison provided a brief overview of the project. The project team presented the
development plans and answered questions from the Panel.
R/2023-ADP-013
It was moved and seconded
That the application be supported as the following concerns be addressed as the design
develops and submitted to Planning staff for follow up.
Architectural Comments:
• Review parking level access to elevator and stairs, building code has requirements
for vestibules between spaces when you are above 3 Storeys in a C occupancy
building
• Review stair width, and dimensions with BC Building Code. Review accessibility
requirements in corridors with BC Building Code.
• Encourage to compare red brick with red wood materials to ensure adequate
contrast
• Consider having higher ceiling for top floor penthouse with opportunity to have
skylights or localized areas with higher ceiling above the roofline
• Consider separating visitors from the residential parking area
• Suggest exploring alternative architectural features to reference adjacent new
developments
• Suggest the brick cladding used on main floor to be increased in height till 2nd floor.
• Glass and metal railing used is good, conveyed their message as used
• Need vestibule at the entrance – explore how it can be incorporated
• Increase visibility of main entrance canopy by raising it taller
Advisory Design Panel Minutes
April 12, 2023
Page 4 of 4
Landscape Comments:
• Suggest access separation between outdoor amenity and public areas
• Suggest introducing additional hierarchy between rooflines and architectural frames
• Consider utilizing wood material in other areas, for example, soffits, balconies, etc.
• Consider more varied amenity offer for outdoor spaces, for example, kids play,
barbeques, overhead canopies, etc.
• Consider use of different material for on-slab planters. Suggest use of brick instead
of wood for
• Review conflict between protected existing tree and proposed location of Hydro PMT
• In the amenity area, there is a planter and seat wall – if you intend that to be a seat
wall provide more space on the ledge
CARRIED UNAMINOUSLY
Note: J. Gabri left the meeting at 7:04 pm.
7. CORRESPONDENCE - NIL
8. ADJOURNMENT
There being no further business, the meeting adjourned at 7:37 p.m.
The next regular meeting of the Advisory Design Panel will be held on Wednesday, May 17,
2023.
Jose Gonzalez, Chair
/ad
2022-034-DP Page 1 of 6
City of Maple Ridge
TO: Advisory Design Panel MEETING DATE: May 17, 2023
FILE NO: 2022-034-DP
SUBJECT: Multi-Family Development Permit
11926, 11936, 11946, 11956 236 Street and 23638 Dewdney Trunk Road
PURPOSE:
An Advisory Design Panel (the “ADP”) submission has been received for the above cited application
and subject properties to permit the construction of a townhouse development with 52 market strata
dwelling units. The proposed development will replace four existing single detached residences on the
subject properties.
The relevant part of the subject properties will need to be rezoned to RM-1 (Low Density Townhouse
Residential) to accommodate the proposal. Council considered rezoning application 2022-034-RZ and
granted first reading for Zone Amending Bylaw No. 7852-2022 on May 10, 2022. The rezoning
application also seeks to rezone the northern part of the subject property located at 23638 Dewdney
Trunk Road to R-2 (Single Detached (Medium Density) Urban Residential) to accommodate a
subdivision for three single family residences.
The Multi-Family Development Permit application made to the City is subject to Section 8.7 of the City’s
Official Community Plan.
BACKGROUND:
Applicant: Kunwar Bir Singh
Legal Description: Lot 48 Section 16 Township 12 New Westminster District Plan
20770;
Lot 47 Section 16 Township 12 New Westminster District Plan
20770;
Lot 46 Section 16 Township 12 New Westminster District Plan
20770;
Lot 45 Section 16 Township 12 New Westminster District Plan
20770;
Lot 3 Except: Part Dedicated Road on Plan LMP3164; Section
16 Township 12 New Westminster District Plan 10361
OCP Designation:
Existing: Urban Residential
Proposed: Urban Residential
Within Urban Area Boundary: Yes
OCP Major Corridor: Yes
2022-034-DP Page 2 of 6
Zoning:
Existing: RS-3 (Single Detached Rural Residential)
Proposed: RM-1 (Low Density Townhouse Residential);
R-2 (Single Detached (Medium Density) Urban Residential)
Surrounding Uses:
North: Use: Single Detached Residential;
Townhouse Residential
Zone: RS-3 (Single Detached (Intensive) Urban
Residential)
RM-1 (Low Density Townhouse Residential)
Designation: Urban Residential
East: Use: Retail
Zone: M-2 (General Industrial)
Designation: Urban Residential
South: Use: Single Detached Residential
Zone: RS-1b (Single Detached (Medium Density)
Residential)
Designation: Urban Residential
West: Use: Townhouse Residential
Zone: RM-1 (Low Density Townhouse Residential)
Designation: Urban Residential
Use of Property:
Existing: Single Detached Residential
Proposed: Townhouse Residential;
Single Detached Residential
Site Area:
Existing: 1.06 hectare (2.61 acres)
Proposed: 0.93 hectares (2.29 acres)
Proposed Vehicular Access: 236 Street
Servicing Requirement: Urban Standard
Fraser Sewer Area: Yes
Flood Plain: No
Relevant Applications:
Current: 2022-034-RZ;
2022-034-VP
2022-034-DP Page 3 of 6
DEVELOPMENT PERMIT AREA:
The development permit application made to the City prompting this submission to the ADP is subject
to the Key Guideline Concepts and the Design Guidelines for a Multi-Family Development Permit
(Section 8.7 of the City’s Official Community Plan).
Key Guideline Concepts:
The following is a brief description and assessment of the proposal’s compliance with the applicable
Key Guideline Concepts:
1. “New development into established areas should respect private spaces, and incorporate
local neighbourhood elements in building form, height, architectural features and massing.”
• Staff Comment: The proposed townhouse development would respect the privacy
of adjacent residential areas. It includes privacy fences along the northern,
southern, and western lot lines. The building form, massing, height, and
architectural features are consistent with the local neighbourhood.
2. “Transitional development should be used to bridge areas of low and high densities, through
means such as stepped building heights, or low rise ground oriented housing located to the
periphery of higher density developments.”
• Staff Comment: The proposed townhouse development has an appropriate density.
It will blend in with the townhouse residences to the north and west, the proposed
single detached residences to the north, and the existing single detached
residences to the south.
3. “Large scale developments should be clustered and given architectural separation to foster
a sense of community, and improve visual attractiveness.”
• Staff Comment: The proposed townhouse development provides architectural
separation through centrally located amenity areas (indoor and outdoor) to foster a
sense of community and improve visual attractiveness.
4. “Pedestrian circulation should be encouraged with attractive streetscapes attained through
landscaping, architectural details, appropriate lighting and by directing parking underground
where possible or away from public view through screened parking structures or surface
parking located to the rear of the property.”
• Staff Comment: The proposed townhouse development encourages pedestrian
circulation through attractive streetscapes and internal pedestrian connections
with appropriate lighting. Parking is generally concealed and located away from
public view.
Design Guidelines:
The Design Guidelines and a full explanation of how the project complies with them or the reasons
why they are not applicable are attached in Appendix I to this memo.
2022-034-DP Page 4 of 6
PLANNING COMMENTS:
1. Proposal:
The applicant is proposing to construct a townhouse development with 52 market strata
dwelling units. Unit configuration breakdown would be as per the table below.
Unit Configuration Number of Units
2-bedroom 12
3-bedroom 40
Total 52
2. Context:
The proposed townhouse development fits well within the neighbourhood context. It will
blend in with the townhouse residences to the north and west, the proposed single detached
residences to the north, and the existing single detached residences to the south.
3. OCP and Zoning Compliance:
The subject properties are designated Urban Residential.
The proposal complies with the designation.
The subject properties are subject to being rezoned to RM-1 (Low Density Townhouse
Residential) to accommodate the proposal and Development Data Sheet (Appendix G)
analyses the compliance of the project with the applicable zone regulations. The proposal
has a density (Floor Space Ratio) of 0.74 FSR which complies with the maximum density of
0.75 FSR, including additional density of 0.15 FSR through a density bonus for providing a
cash contribution at a rate of $344.46 per square metre ($32.00 per square foot).
The following variances will be required:
Setback Variances:
Setback Principal Buildings
(Section 617.7.2)
Building Projections
(Section 403.2.4)
Front Lot Line (Western)
Required 6.0 metres 4.75 metres
Proposed 4.5 metres 3.13 metres
Rear Lot Line (Eastern)
Required 7.5 metres 6.25 metres
Proposed 6.25 metres 5.02 metres
Interior Side Lot Line (Northern)
Required 7.5 metres 6.9 metres
Proposed 2.91 metres N/A
2022-034-DP Page 5 of 6
Interior Side Lot Line (Southern)
Required 7.5 metres 6.9 metres
Proposed 4.42 metres 5.11 metres
Exterior Side Lot Line (Northern)
Required 7.5 metres 6.25 metres
Proposed 1.84 metres N/A
Maximum Building Height Variance:
Section 617.8.1 of the City’s Zoning Bylaw limits maximum building height to 9.5 metres for
townhouse residential principal buildings. The applicant is seeking a variance to have a
maximum building height of 11.13 metres.
Off-Street Parking Design Variances:
Section 4.1 of the City’s Off-Street Parking and Loading Bylaw requires townhouse units in
the RM-1 zone with an enclosed double-car parking garage, in a side-by-side configuration,
to have internal finished dimensions of not less than 6.5 metres in width and 6.7 metres in
length. The applicant is seeking a variance to have internal finished dimensions of 5.81
metres in width and 6.08 metres in length.
Section 4.1 of the City’s Off-Street Parking and Loading Bylaw requires townhouse units in
the RM-1 zone with an enclosed single-car parking garage, in a tandem configuration, to have
an internal finished dimension of not less 6.7 metres in length. The applicant is seeking a
variance to have an internal finished dimension of 6.07 metres in length.
4. Parking and Bicycle Storage:
The required parking for the proposed use is analyzed in the Development Data Sheet
(Appendix G).
5. Environmental, Sustainability & Stormwater Management:
Environmental, sustainability, and stormwater management aspects would be as per the
attached architectural plans, landscape plans, and civil plans.
6. Issues requiring comments from ADP:
There are no guidelines where compliance is a concern and there are no issues which require
specific attention from the ADP.
7. Garbage/Recycling:
Garbage and recycling bins would be located within each townhouse as shown in the
architectural plans.
8. Works Along Abutting Roads:
Include new curb, gutter, sidewalk, new sanitary sewer, water, and storm sewer connections;
street lighting; street trees on all frontages; underground wiring for utility services.
2022-034-DP Page 6 of 6
9. Off Site Upgrades, Utilities and Services:
Please refer to previous comment.
CONCLUSION:
The proposed townhouse development complies with guidelines and there are no issues which require
specific attention from the ADP.
The Planning Department requests that the Advisory Design Panel provide comments on the
development proposal.
Prepared by: Daniel Rajasooriar, MRM
Planner
The following appendices are attached hereto:
Appendix A – Subject Map
Appendix B – Ortho Map
Appendix C – Cover Letter (from Architect)
Appendix D – Coordinated Assessment Strategy Statement (from Architect)
Appendix E – ADP Submission Form (from Architect)
Appendix F – ADP Submission Checklist (from Architect)
Appendix G – Development Data Sheet (from Architect)
Appendix H – Requested Variances (from Architect)
Appendix I – Multi-Family Development Permit Area Guidelines Checklist (from Architect)
Appendix J – Architectural Plans (from Architect)
Appendix K – Landscape Plans (from Landscape Architects)
Appendix L – Civil Plans (from Civil Engineer)
Appendix M – Arborist Report (from Arborist)
DATE: Apr 14, 2022FILE: 2022-034-RZ/DP
11956/ 46/ 36/ 26 236 STREET &23638 DEWDNEY TRUNK ROADPID'S: 009-527-664, 009-527-681,009-527-702, 003-899-993 & 002-684-047
^
PLANNING DEPARTMENT
SUBJECT PROPERTIES
236 ST
119 AVE
237A ST
LANE N OF DTR
120B AVE
120A LANE
118A AVE
236B ST
237 ST
LANE S OF DTR
DEWDNEY TRUNK RDDEWDNEY TRUNK RD
119 AVE
237 ST
237A ST
119 AVE
236 ST
236B ST
119 AVE
237 ST
237 ST
237 ST
236 ST
119 AVE
DEWDNEY TRUNK RD
119B AVE
DEWDNEY TRUNK RD
LANE S OF DTRLANE S OF DTR
Aerial Imagery from the Spring of 2020´
Scale: 1:2,500 BY: AH
DATE: Apr 14, 2022FILE: 2022-034-RZ/DP
11956/ 46/ 36/ 26 236 STREET &23638 DEWDNEY TRUNK ROADPID'S: 009-527-664, 009-527-681,009-527-702, 003-899-993 & 002-684-047
PLANNING DEPARTMENT
SUBJECT PROPERTIES
2021-579-RZ2021-579-DP
2021-579-SD
236 ST
119 AVE
237A ST
LANE N OF DTR
120B AVE
120A LANE
118A AVE
236B ST
237 ST
LANE S OF DTR
DEWDNEY TRUNK RDDEWDNEY TRUNK RD
119 AVE
237 ST
237A ST
119 AVE
236 ST
236B ST
119 AVE
237 ST
237 ST
237 ST
236 ST
119 AVE
DEWDNEY TRUNK RD
119B AVE
DEWDNEY TRUNK RD
LANE S OF DTRLANE S OF DTR
´
Scale: 1:2,500 BY: AH
Legend
Stream
Ditch Centreline
Indefinite Creek
Active Applications (RZ/SD/DP/VP)
The City
schedule
making y
ADP subm
ADP thro
Applicati
Name of
File num
Address
Current Z
Seeking t
Architect
Submissi
Architect
Landscap
Other Pro
Note.: Th
developm
taken fro
bulletin,
Major
per th
build
Group A (Pa
Group B (Pa
Group C Res
Group D & E
Group F (F1
Adv
of Maple Rid
es for submis
your submiss
mission pack
ough your Fil
ion Informa
Applicant
ber
of site
Zone
to appear be
t Informatio
on will be p
t
pe Architect
ofessional (S
he Architects
ments to the
om AIBC Bull
click here.
Occupancy
he current
ing codes
art 3)
art 3)
sidential
E
: Part 3)
isory Des
dge Advisory
ssion deadlin
sion, contact
kage for you
le Manager w
tion:
_________
_________
_________
_________
efore the AD
on:
resented to
_________
_________
State Name
s are require
e ADP that a
letin 31 Build
Public Assem
Hospital, San
Home for the
Aged
Institutional
Hotel or sim
Commercial
Industrial
sign Pane
y Design Pan
ne dates and
t your File M
ur project. Fo
well in adva
__________
__________
__________
___ Propose
DP on this da
ADP by:
__________
__________
& Role) ____
ed to prepar
re in the Ma
dings Requir
Use
mbly
natorium, or
e
ilar occupancy
el Submis
nel (ADP) me
d for the min
Manager to e
orward your
nce of the d
___________
_____
___________
ed Zone ____
ate ________
___________
___________
__________
re plans and
ajor Occupan
ring the Serv
Type
services
− any o
exce
− any b
exce
− all sc
− any b
capa
− any b
− any b
− any b
− any b
− any b
ssion Req
eets monthly
nimum subm
establish wh
r complete s
deadline date
__________
__________
__________
__________
________
_______
___________
to attend a
ncy categori
vices of an A
es of Building or
s of an architect
one‐storey build
eeding 9 m or gro
building of more
eeding 235 m²; a
chools, any size
building (exclud
acity exceeding 1
building with gro
building contain
building contain
building with gro
building with gro
uest Form
y.Refer to t
mission requ
at constitute
ubmission p
e.
__
__
__
__
__________
nd to presen
es cited in th
Architect. Fo
r Parts of Buildin
t under section 6
Act.
ding with an uns
oss area exceed
e than one store
and
ing veterinary h
12 beds
oss area exceed
ning 5 or more d
ning 11 or more g
oss area exceed
oss area exceed
m
he attached
irements. Be
es a complet
package for t
____
nt all
he Table bel
r the entire
ng requiring the
60 of the Archit
supported span
ing 275 m²;
ey with gross are
ospital) with a
ing 470 m²
welling units
guest rooms
ing 470 m²
ing 470 m²
efore
te
the
ow
e
ects
ea
CITY OF MAPLE RIDGE
ADVISORY DESIGN PANEL
2019 APPLICANT SCHEDULE
Meeting Date Applicant
Deadline
January 16, 2019 December 17, 2018
February 20, 2019 January 28, 2019
March 20, 2019 February 25, 2019
April 17, 2019 March 25, 2019
May 15, 2019 April 18, 2019
June 19, 2019 May 27, 2019
July 17, 2019
June 24, 2019
NO AUGUST MEETING
September 18, 2019
August 26, 2019
October 16, 2019
September 23, 2019
November 20, 2019
October 28, 2019
NO DECEMBER MEETING
KASIAN
ARCHITECTURE
INTERIOR
DESIGN AND
PLANNING LTD
1500 West Georgia Street
Suite 1685
Vancouver
British Columbia
Canada
V6G 2Z6
t 604 683 4145
f 604 683 2827
www.kasian.com
Vancouver
Victoria
Calgary
Edmonton
Toronto
Doha
DON W. KASIAN
Architect AIBC, Architect AAA, MAA, NLAA,
NSAA, NWTAA, OAA, SAA, FRAIC, Hon.
FAIA, BES, MArch
DEAN BENVENUTO
Architect AAA, BArch, LEED AP BD + C
AZIZ BOOTWALA
Architect AIBC, Architect AAA, MAA, NWTAA,
SAA, FRAIC, LEED AP, MBA
WOJCIECH BRUS
Architect AIBC, NWTAA, FRAIC, MArch
SUZANNE CAMPBELL
ARIDO, LEED AP, IDC
BILL CHOMIK
Architect AIBC, Architect AAA, OAA, SAA,
FRAIC, Hon. FAIA, RCA, BA, BArch
WILL CRAIG
Architect AIBC, Architect AAA,
RIBA Part II
SANJA DJULEPA
LEED AP BD+C, TSA, MRAIC, MArch
W. SCOTT DOUGLAS
Architect AIBC, Architect AAA, MAA, BArch,
BSc
CRYSTAL GRAHAM
Licensed Interior Designer AAA, ARIDO, RID,
IDC, IIDA, LEED AP
KIM GREEN
DID
ABHISHEK GUPTA
BArch, MBEM, LEED AP
DANIEL HAWRELUK
MArch, MComm, BA, AIBC, RAIC
DOUG JOHNSON
BSc, BArch, Sloan Fellow, MAIBC
JUDITH MACDOUGALL
Architect AAA, LEED AP BD + C,
MArch
DEAN MATSUMOTO
AOCA
SALLY MILLS
AID, RID
ALAN NAKASKA
Architect AIBC, Architect AAA,
BArch, BSc
DOUGLAS NIWA
BID
SCOTT NORWOOD
MAATO, Dip. Arch. Tech
GOLNAZ RAKHSHAN
Architect AIBC, Architect NSAA, LEED AP,
MRAIC, BSArch, MArch
JAMES RICE
OAA, NSAA, MRAIC, MArch (Hons),
BAS (Hons), Dip Arch Tech
KATHERINE ROBINSON
Architect AIBC, Architect AAA, NSAA, MRAIC,
BArch
WARREN SCHMIDT
Architect AIBC, Architect AAA, MRAIC M.Arch
B.E.D
IAN SINCLAIR
MHA, CHE
REQUESTED GARAGE VARIANCE
This project started development during the previous version of the Zoning bylaw so some
dimensions provided don’t meet the new requirements.
The requested variances are outlined in the tables below:
REQUESTED VARIANCES TO SETBACKS
REQUIREMENTS
(m) PROPOSED (m)
FLL WEST (236 STREET)
Principal buildings 6 4.5
Building Projections 4.75 3.13
RLL EAST
Principal buildings 7.5 6.22
Building Projections 6.25 5.02
ISLL NORTH
Principal buildings (electrical closet) 7.5 2.91
Building Projections NA NA
ISLL SOUTH
Principal buildings (electrical closet) 7.5 4.42
Building Projections 6.9 5.11
ESLL NORTH
Principal buildings (electrical closet) 7.5 1.84
Building Projections NA NA
REQUESTED VARIANCES TO BUILDING HEIGHT
REQUIREMENTS (m) PROPOSED (m)
9.5M 11.13M
1
Multi-Family Development Permit Area Guidelines Checklist
Pursuant with Section 8.7 of the Official Community Plan, multi-family developments will be
assessed against the form and character guidelines established by Council and summarised
below.
This checklist is to be prepared by the architect of record for the project to demonstrate the
proposed design was developed in accordance with the form and character guidelines. Please
assess and describe the compliance of the proposed design of the project with respect to the
Key Guideline Concepts and with the Form and Character Guidelines.
Description of the Key Guideline Concepts should be suitable for File Managers to quote in
Development Permit Application Reports to Council. For the Form and Character Guidelines,
clearly describe how the proposed design complies with each of the listed guidelines, or
describes why a guideline is not complied with or why it is inapplicable.
This checklist is to accompany Development Permit Applications and submissions to the ADP.
8.7.1 Key Guideline Concepts Describe how this project and the design complies
1. New development into established areas
should respect private spaces, and
incorporate local neighbourhood
elements in building form, height,
architectural features and massing.
2. Transitional development should be used
to bridge areas of low and high densities,
through means such as stepped building
heights, or low rise ground oriented
housing located to the periphery of a
higher density developments.
2
Key Guideline Concepts (Continued)
3. Large scale developments should be
clustered and given architectural
separation to foster a sense of
community, and improve visual
attractiveness.
4. Pedestrian circulation should be
encouraged with attractive streetscapes
attained through landscaping,
architectural details, appropriate lighting
and by directing parking underground
where possible or away from public view
through screened parking structures or
surface parking located to the rear of the
property.
Guidelines 8.7.1 A
Building Design, Massing and Siting
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Design and siting of buildings should take
advantage of natural features or views
and should enhance privacy and
livability.
2. Residential buildings should front or
appear to front onto public roads
through the use of appropriate
treatment of exteriors, through direct
pedestrian access to individual units from
the public street/sidewalk, or through
the provision of pedestrian walkways
linked to the street. Street frontages
should be emphasized by incorporating
differentiated front, side and rear
oriented facades, with a minimum two
storey facade on the fronting street to
foster a human scale. Buildings that are
designed with an end wall or unit
adjacent to a public street should design
the end unit with the pedestrian entry
facing the street. At significant
intersections, the definition of corners
should be reinforced by buildings that
front on both streets and incorporate
corner cuts.
3
Guidelines 8.7.1 A (Continued)
3. Higher density dwellings should be sited
adjacent to major streets in order to
minimize access problems and to provide
a transition to lower density uses.
4. Multi-family developments adjacent to
lower density or single detached
residential dwellings should:
a) be consistent in form and massing with
the surrounding area;
b) be sited adjacent to major streets to
provide a transition to lower density
uses;
c) concentrate density to the centre of the
development or towards a non-
residential boundary and locate lower
density components adjacent to lower
density residential uses;
d) create a transition in building mass and
form towards the setbacks of the
adjacent neighbourhood;
e) minimize access conflicts;
f) be designed to maximize privacy and
minimize views onto adjoining sites,
particularly for portions of the
development abutting the side yards of
adjacent single detached residential uses.
5. Larger buildings, roof forms and building
frontages should include design
elements and features to:
a) provide variation in the facades to help
reduce the visual length of individual
buildings;
b) have the appearance of a series of
smaller buildings, or as identifiable parts
of a larger concept; and
c) incorporate components that express
strong unit identity and incorporate
direct access to grade for ground-floor
units.
4
Guidelines 8.7.1 A (Continued)
6. New multi-family developments should
use design themes, architectural
features and elements of the
surrounding neighbourhood by
incorporating common elements such as
form, scale, massing and proportion into
the design as a means to reinforce
neighbourhood stability. Examples
include:
a) the articulation of facades, using where
appropriate, elements such as porches,
chimneys, projections, recesses, and
balconies;
b) the placement, size, shape and number
of doors and windows;
c) the location and visual appearance of
garages and/or parking facilities;
d) the selection of appropriate and
compatible roof forms; and
e) the design of hard and soft landscaping.
7. The exposed undersides of balconies and
porches that are visible from a street or
public walkway should be covered with
exterior finishes to provide a finished
appearance to public view.
8. Developments are encouraged to use
the Leadership in Energy and
Environmental Design (LEEDS) standards
in the design of buildings. Techniques
such as rain gardens, vegetated swales,
separation of impervious surfaces,
installing below surface infiltration beds
and tree box filters, and redirecting
water from drain pipes into vegetated
areas are encouraged.
9. Variation in individual unit designs is
encouraged to provide visual interest
and avoid significant repetition either
within a row of townhouses, or between
adjacent rows of units.
5
Guidelines 8.7.1 A (Continued)
10. Garage doors should not face public
streets. Where front facing garage doors
are unavoidable, the impact of garage
doors on the public realm should be
mitigated by:
a) designing residential units with enough
width to include attractive entrances
and windows between garages;
b) recessing garage doors behind the main
building façade;
c) keeping a sufficient width in residential
units to allow the creation of attractive
entrances and fenestration between
garages.
d) grouping garage doors in pairs between
adjacent units to allow building
entrances and facades more prominence
on the street;
e) providing interior spaces that overlook
the street;
f) separating and orienting unit entrances
to the street;
g) providing individual pedestrian
walkways linked to the street;
h) including design details such as transom
windows or glazing in garage doors;
i) a comprehensive landscape plan that
identifies how the visual impact of
garage doors from the street will be
mitigated.
11. Landscaping of rooftops is encouraged
where possible, to provide shared or
private outdoor space for residents and
to provide attractive views for residents
and passersby.
6
Guidelines 8.7.1 B
Vehicle Access, Parking and Circulation
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Parking and servicing should be located
underground or to the rear of buildings,
with access from lanes wherever
possible. Where lane access is not
possible, access should be from streets
via narrow driveways to minimize the
impact on streetscape appearance and
disruption to pedestrian movement.
2. Parking structures should be adequately
screened and architecturally compatible
with the rest of the building. Large
surface parking areas should be divided
into smaller sections to avoid a
monotonous appearance with
landscaping strips, trees, building edges,
pedestrian pathways, and pavement
treatment to enhance their visual
appearance.
3. Developments with large parking areas
should provide a direct pedestrian
pathway system through the parking
area to facilitate convenient and safe
pedestrian access between building
entrances, parked cars, and sidewalks of
adjoining streets. Features such as
special landscaping with trees and
benches, overhead weather protection
and distinct paving should be
incorporated where appropriate.
Pedestrian movement should be
designed to avoid any obstruction by
parked vehicles.
4. Shared vehicle access between adjoining
sites should be considered where access
for parking at the rear of the property is
limited. Joint or shared access should
also be considered between adjoining
developments to minimize disruption of
pedestrian sidewalks and to maximize
landscaping and permeable surfaces.
Integration of driving aisles and
pedestrian walkways between adjacent
sites is also strongly encouraged.
7
Guidelines 8.7.1 B (Continued)
5. Locate parking spaces allocated for
people with disabilities as close as
possible to the main entrance to a
building.
6. Crime Prevention through
Environmental Design (CPTED) principles
should be incorporated into the design
of all parking facilities with convenient,
safe, identifiable and universally
accessible access routes to building
entrances, lobbies or other principal
areas of buildings, and to grade level
from any underground or above ground
parking structures.
7. To increase safety, consider using
electronic security devices and
monitoring systems as a supplement to
natural surveillance opportunities in
parking structures and parking areas.
8. The amount of asphalt surfaces in
parking areas should be minimized by
integrating a variety of paving materials
such as concrete, decorative pavers, etc.
or by using alternate surface treatments.
9. Road grades, streets, lanes, and
driveways should conform to the
existing grades as closely as possible to
ensure minimal disruption of slopes and
vegetation. On steep terrain, roads
should be aligned, wherever possible, to
run parallel rather than counter to,
natural contours and existing grades.
8
Guidelines 8.7.1 C
Landscaping and Open Space
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Landscaping both within and outside the
development should:
a) provide definition for pedestrian
corridors;
b) delineate private and semi private space
from public space;
c) provide adequate screening between
private outdoor spaces;
d) present a pleasing street image;
e) provide suitable buffering between
public road and privacy areas;
f) soften the transition between adjacent
land uses;
g) provide a buffer between residential and
non-residential land uses;
h) create interesting views and focal points
into and out of the site;
i) reinforce design continuity with
neighbouring properties, the scale and
massing of buildings, and the
streetscape by providing consistency in
street trees, plant materials, and other
landscaping elements.
2. Landscape drawings for development
applications should include, but are not
limited to, the following information:
a) the location of mature and existing trees
to be retained or removed,
b) the location of all protective tree
fencing;
c) a grading plan or cross section indicating
finished grade; and
d) a drainage plan for the site.
3. Street trees will be a required
component of all development.
Incorporate deciduous tree species into
streetfront landscaping to define site
boundaries, to enhance public space,
and to permit light penetration in
winter.
9
Guidelines 8.7.1 C (Continued)
4. Energy efficiency and conservation
should be considered in the design of
landscaped areas and in the selection of
plant material. This can be
accomplished through:
a) using native and/or drought-resistant
species;
b) designing the landscaping to moderate
the effect of wind;
c) providing shade in summer;
d) allowing natural drainage to occur
throughout the site;
e) allowing daylight into buildings; and
f) redirecting water from rooftop runoff
and downspouts into vegetated areas or
rain barrels for later irrigation use.
5. Maintain continuous landscaping along
abutting streets and minimize the
number of interruptions such as
driveways and parking entrances.
Continue the sidewalk pavement across
driveways and parking entrances.
6. Create visual landmarks on significant
street corners and at locations of high
visibility. Provide landscaping and
consider incorporating features such as
flag poles, banners, visual art,
ornamental trees, fountains,
architectural elements, and landscape
structures.
7. Any portion of a building site left vacant
for future development should be
landscaped consistent with the
landscape plan for the overall site. The
minimum ground surface treatment
should be lawn. Where possible, the
natural state should be retained for
those portions of a property not being
developed.
10
Guidelines 8.7.1 C (Continued)
8. Identify, preserve and incorporate
stands of mature trees into the overall
site landscaping design. Retain unique
tree species, significant vegetation,
natural landscape features and nesting
areas on a site wherever possible. To
attain this objective, prior to the design
of a project, a detailed survey prepared
by a qualified professional indicating the
location and condition of existing trees
and vegetation on a site should be
conducted and provided to the District
as part of the development application
process.
9. Existing vegetation should be enhanced
with new planting wherever
construction activity has destroyed
vegetation. Replanting with indigenous
or native species is encouraged.
10. Consider incorporating rain gardens and
vegetated swales into parking lot
landscaping to increase the natural
absorption of rainwater runoff from
paved areas into the ground.
11. The height and location of a landscape
screen should ensure that:
a) privacy to adjacent properties is
adequately protected;
b) driving site lines are maintained from
adjacent roads, manoeuvring aisles,
parking lots; and
c) the quality of the streetscape and
outdoor living spaces is enhanced.
12. Maximize the amount of landscaped
areas and minimize the amount of
impervious paved surfaces to increase
the natural absorption of rainwater on a
site.
11
Guidelines 8.7.1 D
Universally Accessible Design
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. All non-vehicular routes should be fully
accessible. Sidewalks and pathways
should be wide enough for
wheelchair/scooters and should include
a tactile strip for the visually impaired.
Curb-cuts and curb let-downs should be
provided in appropriate locations to
facilitate safe, convenient, and direct
access from parking spaces to buildings
for people with disabilities.
2. Building entries should be:
a) clearly addressed with large numbers
visible from the street;
b) directly accessed from the street
without stairs;
c) provided with level areas measuring a
minimum of 1.5m x 1.5m (4.9 ft. x 4.9 ft.)
both inside and outside of doorways;
and
d) provided with weather protection,
exterior lighting, and power-assisted
door openers.
Guidelines 8.7.1 E
Refuse, Recycling and Service Areas
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Integrate vents, mechanical rooms,
mechanical equipment, and elevator
penthouses into the roof design or
screen with materials and finishes
compatible with the overall architectural
design.
2. The design of a roof, placement of
mechanical units and satellite dishes,
etc. should take into account views of
the roof from adjacent buildings.
12
3. Garbage containers and recycling bins
must be:
a) easily accessible;
b) appropriately sized for the building
occupants;
c) contained within roofed/walled
enclosures;
d) incorporated into the overall design of
the development; or
e) screened from public view and
weatherproof and animal-resistant
within the boundaries of each site.
4. Service areas should be internalized
within the development. For
developments with multiple buildings,
common refuse, recycling and service
areas are to be provided. Storage areas
should be located to be convenient and
readily accessible from most buildings or
units on the site. Avoid direct exposure
from public streets and allow for
adequate manoeuvring space for
removal vehicles.
5. Enclose or screen all exterior mechanical
units or equipment, including roof top
units, equipment, and satellite dishes
within upper floors or structures that
from part of the overall design of a
development.
6. Locate building ventilation systems to
minimize noise and exhaust pedestrian
areas, residential units, and outdoor
spaces and locate less sensitive land uses
closer to sources of noise.
7. Buildings should be designed and
constructed maximize sound
attenuation:
a) between units;
b) between public roads and units; and
c) between adjacent land uses and units.
13
Guidelines 8.7.1 F
Signage and Lighting
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. All signage must conform to the Maple
Ridge Sign Bylaw. In the event of a
conflict between the Maple Ridge Sign
Bylaw and these guidelines, the latter
shall take precedent.
2. Signage design, materials and message
should be integrated and complement
the scale and architectural detail of the
building.
3. Pedestrian level lighting is encouraged
along all pedestrian routes and
pedestrian plazas. The lighting should
be pedestrian focused.
4. Lighting should be designed so as to
have no direct source of light visible
from the public right-of-way or adjacent
residential land. Care should be taken to
ensure that lighting glare does not pose
a nuisance to adjacent residences,
pedestrians, or motorists.
Guidelines 8.7.1 G
Bicycle Parking and Storage
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Short term and long term bicycle parking
facilities should be considered for all
developments. Short term bicycle
parking should be in well-lit locations
and clearly visible from a main building
entrance and/or public roads with
bicycle racks made of sturdy, theft-
resistant material that is securely
anchored to the floor or ground. Longer
term bicycle storage areas provided as
part of a parking structure should be
located close to elevators and access
points.
LANDSCAPE CONSULTANT
PMG LANDSCAPE ARCHITECTS
Suite C100 -4185 Still Creeek Drive
Burnaby, British Columbia, V5C 6G9
p : 604-294-0011
f : 604 294-0022
ARBORIST CONSULTANT
WOODRIDGE TREE CONSULTING
ARBORISTS LTD.
2513 141 St, Surrey, BC V4P 2E5,
Canada
Ph: +1 778-847-0669
Email : terry@woodridgetree.com
ARCHITECTURE & INTERIOR DESIGN
KASIAN ARCHITECTURE INTERIOR
DESIGN AND PLANNING LTD.
19951 80A Avenue, Unit 303 & 342,
Westlund Building Langley, B.C., Canada
| V2Y 0E2
P: (604) 631-8203
E: Doug.Johnson@kasian.com
CIVIL CONSULTANT
Aplin & Martin Consultants Ltd.
3862 W. 14 Avenue
Vancouver, B.C. Canada V6R 2W9
Phone: 604-817-4695
Email: dlaird@aplinmartin.com
SURVEY CONSULTANT
Target Land Surveying
Unit C120-20178 96 Ave
Langley, BC V1M 0B2
Phone: 604-583-6161
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-001
COVER PAGE
23638 TOWNHOUSES
722067
SS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
PROPOSED TOWNHOUSES DEVELOPMENT
23638-DEWDNEY TRUNK RD,MAPLE RIDGE ,BC
ISSUED FOR ADP SUBMISSION
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DRAWING NO.
23638-TOWN HOUSES
PROJECT NO.
722067
PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
23638 DEWDNEY TRUNK RD,
REV.YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
MAPLE RIDGE, B.C. CANADA.
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
VICINITY MAP
ADP-0.01
1
N.T.S
SHEET INDEX
SHEET NO.ARCHITECTURAL
CONTEXT MAP
DP-2 SERIES SITE PLANS
DP-0 SERIES DATA SHEET
23638 - TOWNHOUSES
DEWDNEY TRUNK RD, MAPLE RIDGE, BC., CANADA.
DATA SHEET
PROJECT SITE
NTS
ISSUED FOR ADP SUBMISSION
ADP-0.01 4
AD
CY
2023-04-17
DATA SHEET
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-0.10
3D VIEW FROM 236 ST.
23638 TOWNHOUSES
722067
SS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
01
BU
I
L
D
I
N
G
-
02
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-0.20
3D VIEW ADP-0.20
23638 TOWNHOUSES
722067
CY
AS
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
09
BU
I
L
D
I
N
G
-
08
BU
I
L
D
I
N
G
-
07
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-0.30
3D VIEW ADP-0.30
23638 TOWNHOUSES
722067
CY
AS
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
04
BU
I
L
D
I
N
G
-
03
BU
I
L
D
I
N
G
-
06
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
⅊
BU
I
L
D
I
N
G
1
BU
I
L
D
I
N
G
2
BU
I
L
D
I
N
G
4
BU
I
L
D
I
N
G
3
BU
I
L
D
I
N
G
5
BU
I
L
D
I
N
G
7
BU
I
L
D
I
N
G
6
BU
I
L
D
I
N
G
8
BU
I
L
D
I
N
G
9
DRAWING NO.
23638-TOWN HOUSES
PROJECT NO.
722067
PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
23638 DEWDNEY TRUNK RD,
REV.YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
MAPLE RIDGE, B.C. CANADA.
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
CONTEXT PLAN
DP-2.02
1
1/64" = 1'-0"
ISSUED FOR ADP SUBMISSION
ADP-2.02 4
1/64" = 1'-0"
AG
ML
PERMEABLE GREEN SURFACE
2023-04-28
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
28-04-2023
ADP-2.03
PHOTO BOARD
23638 TOWNHOUSES
722067
Author
Checker
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
2 2'
1
1'
23
6
S
T
DEWDNEY TRUNK ROAD
BUIL
D
I
N
G
-
0
1
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAREA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
-
2
BU
I
L
D
I
N
G
-
3
BU
I
L
D
I
N
G
-
6
BU
I
L
D
I
N
G
-
8
AM
E
N
I
T
Y
DEWDNEY ROAD LOOKING TOWARDS EAST1 DEWDNEY ROAD LOOKING TOWARDS NORTH2 TOWARDS SITE (DEWDNEY ROAD)3
TOWARDS SOUTH 236 STREET4 TOWARDS EAST 236 STREET5 DEWDNEY ROAD LOOKING TOWARDS WEST6
TOWARDS NORTH 236 STREET7
1
3
26
4
7
5
11956
11962
1196211962
1196211962
11962
23608 23612 23616 23622 23628
23638
11946
11936
11926
23652
OUTDOOR
AMENITY AREA
257.54 SQ.M
23
6
S
T
6M LANE
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.0
M
W
I
D
E
D
R
I
V
E
W
A
Y
BUILDING-01
BUILDING-02
BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
EMERGENCY ACCESS
6.0M WIDE DRIVEWAY
VP
02
VP
03
VP 01
VP
04
H/C
06
VP 12
H/C 07
VP 08
0.10
01
32.76M
[107'-512"]
11
1
.
5
0
M
[3
6
5
'
-
9
1
2"]
32.86M
[107'-912"]
65.41M
[214'-7"]0.30M
[1']
85
.
3
4
M
[2
8
0
'
]
65.61M
[215'-312"]
26
.
1
5
M
[8
5
'
-
9
12"]19.88M
[65'-3"]
26
.
1
5
M
[8
5
'
-
9
12"]
26
.
1
5
M
[8
5
'
-
9
1
2"]19.80M
[64'-1112"]
13
.
3
9
M
[4
3
'
-
1
1
"
]
12
.
7
6
M
[4
1
'
-
1
0
12"]
19.91M
[65'-4"]
26
.
1
6
M
[8
5
'
-
1
0
"
]
32.72M
[107'-4"]
62.66M
[205'-7"]
4.15
M
[13'
-
7
1 2"]
27
.
5
2
M
[9
0
'
-
3
12"]
65.57M
[215'-112"]
32.75M
[107'-512"]
30
.
5
5
M
[1
0
0
'
-
3
"
]
7.5
0
M
[2
4
'
-
7
12"]
UNIT-B1
01
UNIT-B
02
03
04
05
06
07
08
09
10
11
12
UNIT-B1
UNIT-B1
UNIT-B
UNIT-B
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
13
14
15
16
17
18
19
20
21
22
23 24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-A
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
0.20
01
0.30
01
⅊⅊
⅊
⅊⅊
⅊
⅊
⅊⅊
⅊
⅊⅊
⅊⅊
⅊
⅊
MA
I
N
EN
T
R
Y
/
E
X
I
T
DEWDNEY TRUNK ROAD
F.
T
D
I
S
T
A
N
C
E
-
4
3
.
7
3
M
VP
05
VP
13
F.
T
D
I
S
T
A
N
C
E
-
4
5
M
F.
T
D
I
S
T
A
N
C
E
-
4
5
M
F.
T
D
I
S
T
A
N
C
E
-
4
2
M
F.
T
D
I
S
T
A
N
C
E
-
4
5
M
F.
T
D
I
S
T
A
N
C
E
-
4
1
.
1
M
F.
T
D
I
S
T
A
N
C
E
-
4
3
.
2
8
M
F.
T
D
I
S
T
A
N
C
E
-
3
6
.
5
7
M
F.
T
D
I
S
T
A
N
C
E
-
3
6
.
6
6
M
⅊EXISTING PROPERTY LINE
OUT DOOR AMENITY AREA
SPECIALTY PAVING
SITE LEGEND
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
SIDE WALK
FIRE TRUCK LINE
ROAD DEDICATION
LOT 1
336.53 SQ.M
LOT 2
336.53 SQ.M
LOT 3
336.53 SQ.M
EXISTING MULTI FAMILY
FUTURE R-3 LOTS
CATCH BASIN
SYMBOL LEGEND
ELEVATION VIEW
STREET VIEW
XXX
XX
XXX
XX
DROP IN LEVEL
X X SITE SECTION
SLOPE DIRECTION
INDOOR AMENITY
AREA (2 STOREY)
185.0 SQ.M
OUTDOOR
AMENITY AREA
257.98 SQ.M
ADP-4.03
01
DRAWING NO.
23638-TOWN HOUSES
PROJECT NO.
722067
PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
23638 DEWDNEY TRUNK RD,
REV.YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
MAPLE RIDGE, B.C. CANADA.
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRE TRUCK ACCESS ROUTE
DP-2.11
1
1/24" = 1'-0"
ISSUED FOR ADP SUBMISSION
ADP-2.12 4
1/24" = 1'-0"
AG
ML
FIRE TRUCK ACCESS ROUTE
2023-04-26
11956
11962
1196211962
1196211962
11962
23608 23612 23616 23622 23628
23638
11946
11936
11926
23
6
S
T
6M LANE
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.
0
M
W
I
D
E
D
R
I
V
E
W
A
Y
6.0
M
W
I
D
E
D
R
I
V
E
W
A
Y
BUILDING-01
BUILDING-02
BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
EMERGENCY ACCESS
6.0M WIDE DRIVEWAY
VP
02
VP
03
VP 01
VP
04
H/C
06
VP 12
H/C 07
VP 08
0.10
01
32.76M
[107'-512"]
11
1
.
5
0
M
[3
6
5
'
-
9
12"]
32.86M
[107'-912"]
65.41M
[214'-7"]0.30M
[1']
85
.
3
4
M
[2
8
0
'
]
65.61M
[215'-312"]
26
.
1
5
M
[8
5
'
-
9
12"]19.88M
[65'-3"]
26
.
1
5
M
[8
5
'
-
9
1
2"]
26
.
1
5
M
[8
5
'
-
9
1
2"]19.80M
[64'-1112"]
13
.
3
9
M
[4
3
'
-
1
1
"
]
12
.
7
6
M
[4
1
'
-
1
0
12"]
19.91M
[65'-4"]
26
.
1
6
M
[8
5
'
-
1
0
"
]
32.72M
[107'-4"]
62.66M
[205'-7"]
4.15
M
[13'-
7
1 2"]
27
.
5
2
M
[9
0
'
-
3
12"]
65.57M
[215'-112"]
32.75M
[107'-512"]
30
.
5
5
M
[1
0
0
'
-
3
"
]
7.5
0
M
[2
4
'
-
7
12"]
UNIT-B1
01
UNIT-B
02
03
04
05
06
07
08
09
10
11
12
UNIT-B1
UNIT-B1
UNIT-B
UNIT-B
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
13
14
15
16
17
18
19
20
21
22
23 24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-C
UNIT-A
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-B1
UNIT-B
UNIT-A
UNIT-A
UNIT-A
UNIT-A
UNIT-A
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
ELEC.CLOSET
10'-6" x 3'-0"
0.30
01
⅊⅊
⅊
⅊⅊
⅊
⅊
⅊⅊
⅊
⅊⅊
⅊⅊
⅊
⅊
MA
I
N
EN
T
R
Y
/
E
X
I
T
DEWDNEY TRUNK ROAD
VP
05
VP
13
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
1.
5
M
W
I
D
E
S
I
D
E
W
A
L
K
LOT 1
336.53 SQ.M
LOT 2
336.53 SQ.M
LOT 3
336.53 SQ.M
EXISTING MULTI FAMILY
FUTURE R-3 LOTS
INDOOR AMENITY
AREA (2 STOREY)
185.0 SQ.M
OUTDOOR
AMENITY AREA
257.98 SQ.M
ADP-4.03
01
OUTDOOR
AMENITY AREA
257.54 SQ.M
DRAWING NO.
23638-TOWN HOUSES
PROJECT NO.
722067
PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
23638 DEWDNEY TRUNK RD,
REV.YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
MAPLE RIDGE, B.C. CANADA.
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRE TRUCK ACCESS ROUTE
DP-2.11
1
1/24" = 1'-0"
ISSUED FOR ADP SUBMISSION
ADP-2.12 4
1/24" = 1'-0"
AG
ML
PERMEABLE GREEN SURFACE
2023-04-27
UP
DN
UP UP UP UP UP
UP UP UP UP UP UP
DN DN DN DN DN DN
UP UPUPUPUP
ADP-5.114
ADP-5.11
ADP-5.11
ADP-5.11
1
3
2
PATIO PATIO PATIO
18' - 5"
PR
O
P
E
R
T
Y
L
I
N
E
ADP-6.11
1
ADP-6.11 3
ADP-6.114
ADP-6.11
2
1.7
%
YARD YARD YARD
MECH. RM.
2.
0
%
2.
0
%
1.
7
%
2.
0
%
2.
0
%
PATIO PATIO PATIO
YARDYARDYARD
MECH. RM.MECH. RM.MECH. RM.MECH. RM.MECH. RM.
272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
268 SF
(24.9 SM)
GARAGE
40
'
-
9
"
101' - 0"
12' - 5"4' - 7"12' - 3"4' - 7"12' - 3"4' - 7"12' - 3"4' - 7"12' - 3"4' - 7"12' - 1"4' - 7"
16' - 10"16' - 10"16' - 10"16' - 10"16' - 10"16' - 10"
37
'
-
3
"
BUILDING LINE ABOVE
19
'
-
1
1
"
3' - 6"
3' - 2"
4'
-
1
0
"
BUILDING
LINE ABOVE
ROOF LINE ABOVE
ROOF LINE ABOVE
19
'
-
9
"
163'-1"
49.70 m
162'-1"
49.40 m
162'-1"49.40 m
163'-1"
49.70 m
163'-1"
49.70 m
162'-1"
49.40 m
163'-6"
49.85 m
161'-7"
49.25 m
163'-6"
49.85 m
161'-7"
49.25 m
163'-6"
49.85 m
161'-7"
49.25 m
UNIT #06 (153 SF)
UNIT TYPE B
UNIT #05 (153 SF)
UNIT TYPE B1
UNIT #04 (153 SF)
UNIT TYPE B
UNIT #03 (153 SF)
UNIT TYPE B1
UNIT #02 (153 SF)
UNIT TYPE B
UNIT #01 (156 SF)
UNIT TYPE B1
4.
9
%
4.
9
%
4.
9
%
2.
4
%
2.
4
%
2.
4
%
DN DNDN DN DN DN
3'
-
2
"
BICYCLE
RACK
5'
-
1
1
"
3' - 6"
2' - 5 1/2"
3'
-
7
1
/
2
"
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
ADP-5.114
ADP-5.11
ADP-5.11
ADP-5.11
1
3
2
ADP-6.11
1
ADP-6.11 3
ADP-6.114
ADP-6.11
2
DECK DECK DECK DECK DECK DECK
2'
-
0
"
39
'
-
0
"
16' - 10"16' - 10"16' - 10"16' - 10"16' - 10"16' - 10"
101' - 0"
9' - 0 1/2"23' - 1 1/2"10' - 6 1/2"23' - 1 1/2"10' - 6 1/2"22' - 7 1/2"2' - 0"
BUILDING LINE ABOVE
DINING
KITCHEN
FAMILY
BATH
LIVING
LEDGE
FAMILY
KITCHEN
DINING
LIVING
BATH
LEDGE
FAMILY
KITCHEN
DINING
LIVING
BATH
LEDGE
KITCHEN
FAMILY
BATH
LIVING
DINING
LEDGE
KITCHEN
FAMILY
BATH
LIVING
DINING
LEDGE
KITCHEN
FAMILY
BATH
DINING
LIVING
LEDGE
2' - 11 1/2"
UNIT #06 (672 SF)
UNIT TYPE B
UNIT #05 (687 SF)
UNIT TYPE B1
UNIT #04 (672 SF)
UNIT TYPE B
UNIT #03 (687 SF)
UNIT TYPE B1
UNIT #02 (672 SF)
UNIT TYPE B
UNIT#01 (686 SF)
UNIT TYPE B1
8' - 8"
6' - 10 1/2"
8'
-
0
1
/
2
"
3'
-
2
"
3' - 2"
12' - 2 1/2"
6' - 10 1/2"
39
'
-
0
"
2'
-
0
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
28-04-2023
ADP-3.11
BUILDING-01 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 FIRST FLOOR LEVEL (UN 01-06)
1/8" = 1'-0"2 SECOND FLOOR LEVEL (UN 01-06)
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
1
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DNDNDNDN
ADP-5.114
ADP-5.11
ADP-5.11
ADP-5.11
1
3
2
ADP-6.11
1
ADP-6.11 3
ADP-6.114
ADP-6.11
2
M.BED RM
42
'
-
9
"
2'
-
0
"
101' - 0"
13' - 3 1/2"20' - 4 1/2"13' - 3 1/2"20' - 4 1/2"13' - 3 1/2"20' - 4 1/2"
21' - 8 1/2"11' - 11 1/2"21' - 8 1/2"11' - 11 1/2"21' - 8 1/2"11' - 11 1/2"
9' - 0 1/2"23' - 1 1/2"10' - 6 1/2"23' - 1 1/2"10' - 6 1/2"22' - 7 1/2"2' - 0"
11' - 2 1/2"
ROOF LINE ABOVE
ROOF LINE ABOVE
BED RM
BATH
W.I.C
M.BED RM
W/D
BED RM
BATH
M.BED RM
W.I.C
ENSUITE
BATH
BED RM
BED RM
W/D
M.BED RM
W.I.C
ENSUITE
BATH
BED RM
BED RM
W/D
BED RM BED RM
BATH
ENSUITE
W.I.C
M.BED RM
W/D
BED RM BED RM
BATH
ENSUITE
W.I.C
M.BED RM
W/D
M.BED RM
W.I.C
BATH
BATH
W/D
BED RM
BED RM
8' - 8"
10
'
-
4
"
3' - 4"
3'
-
4
"
3' - 4"
10
'
-
8
1
/
2
"
5'
-
3
"
6'
-
5
1
/
2
"
3'
-
1
0
"
8' - 10"
UNIT #06 (743 SF)
UNIT TYPE B
UNIT #05 (710 SF)
UNIT TYPE B1
UNIT #04 (744 SF)
UNIT TYPE B
UNIT #03 (710 SF)
UNIT TYPE B1
UNIT #02 (743 SF)
UNIT TYPE B
UNIT #01 (709 SF)
UNIT TYPE B1
12' - 4 1/2"
12
'
-
3
1
/
2
"
11' - 9"
5'
-
0
"
6'
-
0
"
4'
-
0
"
12
'
-
8
1
/
2
"
8' - 6"
3' - 2"
5'
-
8
1
/
2
"
ADP-5.114
ADP-5.11
ADP-5.11
ADP-5.11
1
3
2
BUILDING LINE BELOW
ADP-6.11
1
ADP-6.11 3
ADP-6.114
ADP-6.11
2
BUILDING LINE BELOW
9" / 12"9" / 12"
9" / 12"
9" / 12"
4"
/
1
2
"
4"
/
1
2
"
9" / 12"
9" / 12"
9" / 12"9" / 12"
2'
-
0
"
3'
-
7
"
2' - 0"
4'
-
0
"
2'
-
0
"
3'
-
7
"
2' - 0"
2'
-
0
"
4'
-
0
"
12' - 10 1/2"10' - 10 1/2"10' - 10 1/2"10' - 10 1/2"25' - 0 1/2"10' - 10 1/2"10' - 10 1/2"12' - 10 1/2"
48
'
-
9
"
UNIT #06
UNIT TYPE B
UNIT #05
UNIT TYPE B1
UNIT #04
UNIT TYPE B
UNIT #03
UNIT TYPE B1
UNIT #02
UNIT TYPE B
UNIT #01
UNIT TYPE B1
9" / 12"9" / 12"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-3.12
BUILDING-01 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 THIRD FLOOR LEVEL (UN 01-06)
1/8" = 1'-0"2 ROOF PLAN (UN 01-06)
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
1
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
UP
UP UP UP
UP UP
DN
DN
DN DN
DN DN
ADP-5.214
ADP-5.21
ADP-5.21
1
3
415 SF
(38.6 SM)
GARAGE
416 SF
(38.7 SM)
GARAGE 415 SF
(38.6 SM)
GARAGE
416 SF
(38.7 SM)
GARAGE
415 SF
(38.6 SM)
GARAGE
415 SF
(38.6 SM)
GARAGE
PWDR RM
PWDR RM PWDR RM PWDR RM
PWDR RM PWDR RM
4.9
%
4.
9
%
4.
9
%
3.
2
%
3.
2
%
3.
2
%
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
32
'
-
2
"
4'
-
0
"
36
'
-
2
"
11' - 3 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
PATIO
PATIO PATIO PATIO
PATIO PATIO
163'-1"49.70 m
163'-1"
49.70 m
163'-1"
49.70 m
162'-3"
49.45 m
162'-3"
49.45 m
162'-3"
49.45 m
163'-7"
49.85 m
163'-7"
49.85 m
163'-7"
49.85 m
162'-9"
49.60 m
162'-9"49.60 m
162'-9"
49.60 m
18' - 0 1/2"
18
'
-
6
1
/
2
"
2'
-
0
"
30
'
-
2
"
4'
-
0
"
19' - 1"
19
'
-
1
1
1
/
2
"
3'
-
0
"
5'
-
7
"
4' - 8"
ADP-6.21
1
ADP-6.21 4
ADP-6.213
0.8
%
1.
7
%
2.
5
%
1.
3
%
1.
3
%
FLEX RM
FLEX RM FLEX RM FLEX RM
FLEX RM FLEX RM
UNIT #12 (211 SFT)
UNIT TYPE A
UNIT #11 (210 SFT)
UNIT TYPE A
UNIT #10 (211 SFT)
UNIT TYPE A
UNIT #09 (211 SFT)
UNIT TYPE A
UNIT #08 (211 SFT)
UNIT TYPE A
UNIT #07 (210 SFT)
UNIT TYPE A
19' - 10"60' - 4"39' - 10"
162'-7"
49.55 m
162'-7"
49.55 m
162'-7"49.55 m 162'-1"
49.40 m
162'-1"
49.40 m
162'-1"
49.40 m
10
'
-
7
"
BALCONY LINE
ABOVE
ROOF LINE
ABOVE
ADP-5.21
2
ADP-6.21
2
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
YARD YARD YARD YARD YARD YARD
10' - 2 1/2"
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
GARBAGE
BINS
BICYCLE
RACK
MECH.
ROOM
19' - 3"
ADP-5.214
ADP-5.21
ADP-5.21
ADP-5.21
1
3
2
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
32
'
-
2
"
4'
-
0
"
36
'
-
2
"
11' - 3 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
31
'
-
1
"
DECK DECK DECK DECK
DECK DECK
ADP-6.21
1
ADP-6.21 4
ADP-6.213
ADP-6.21
2
UNIT #12 (626 SFT)
UNIT TYPE A
UNIT #11 (627 SFT)
UNIT TYPE A
UNIT #10 (626 SFT)
UNIT TYPE A
UNIT #09 (627 SFT)
UNIT TYPE A
UNIT #08 (627 SFT)
UNIT TYPE A
UNIT #07 (626 SFT)
UNIT TYPE A
LIVING
DINING STUDY
PWDR RMKITCHEN
LIVING
DINING
STUDY
KITCHEN PWDR RM
LIVING
DINING STUDY
KITCHEN PWDR RM
LIVING
DINING STUDY
KITCHEN PWDR RM
LIVING
DINING STUDY
KITCHEN PWDR RM
LIVING
DINING STUDY
KITCHEN PWDR RM
19' - 1"
5' - 0"
3'
-
0
"
2'
-
0
"
5'
-
5
1
/
2
"
3' - 0"
4'
-
0
"
30
'
-
2
"
2'
-
0
"
32
'
-
2
"
19' - 10"60' - 4"39' - 10"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
01-05-2023
ADP-3.21
BUILDING-02 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 FIRST FLOOR UN (7-12)
1/8" = 1'-0"2 SECOND FLOOR UN (7-12)
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
2
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DN
DN DN DN
DN DN
ADP-5.214
ADP-5.21
ADP-5.21
ADP-5.21
1
3
2
3"
/
1
2
"
34
'
-
2
"
4'
-
0
"
34
'
-
2
"
11' - 3 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
11' - 3 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
2'
-
0
"
30
'
-
2
"
2'
-
0
"
ROOF LINE ABOVE
ADP-6.21
1
ADP-6.21 4
ADP-6.213
ADP-6.21
2
UNIT #12 (649 SFT)
UNIT TYPE A
UNIT #11 (649 SFT)
UNIT TYPE A
UNIT #10 (649 SFT)
UNIT TYPE A
UNIT #09 (649 SFT)
UNIT TYPE A
UNIT #08 (649 SFT)
UNIT TYPE A
UNIT #07 (649 SFT)
UNIT TYPE A
M.BED RM
BED RM
ENSUITE
BATH
BED RM
W/D
M. BED ROOM BED ROOM
ENSUITE
BATH
BED ROOM
W/D
M. BED ROOM BED ROOM
ENSUITE
BATH
BED ROOM
W/D
M. BED ROOM BED ROOM
ENSUITE
BATH
BED ROOM
W/D
M. BED ROOM
BED ROOM
ENSUITE
BATH
BED ROOM
W/D
M.BED RM
BED RM
ENSUITE
BATH
BED RM
W/D
10' - 2 1/2"
10
'
-
2
1
/
2
"
8' - 6"
8'
-
1
1
1
/
2
"
5'
-
0
"
3' - 0"4' - 11 1/2"
10' - 2 1/2"
10
'
-
3
"
6' - 6"
7'
-
0
"
3' - 4"
2'
-
0
"
2'
-
0
"
ADP-5.214
ADP-5.21
ADP-5.21
ADP-5.21
1
3
2
BUILDING LINE BELOW
60' - 0"
ADP-6.21
1
ADP-6.21 4
ADP-6.213
ADP-6.21
2
UNIT #12 (649 SFT)
UNIT TYPE A
UNIT #11 (649 SFT)
UNIT TYPE A
UNIT #10 (649 SFT)
UNIT TYPE A
UNIT #09 (649 SFT)
UNIT TYPE A
UNIT #08 (649 SFT)
UNIT TYPE A
UNIT #07 (648 SFT)
UNIT TYPE A
2'
-
0
"
124' - 0"
22' - 0"42' - 0"
13' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"10' - 8 1/2"
4'
-
0
"
2'
-
0
"
2' - 0"
4'
-
0
"
2'
-
0
"
38
'
-
2
"
38
'
-
2
"
7" / 12"7" / 12"7" / 12"7" / 12"7" / 12"7" / 12"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-3.22
BUILDING-02 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 THIRD FLOOR UN (7-12)
1/8" = 1'-0"2 ROOF PLAN UN (7-12)
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
2
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
UP
UP
UP UP
UP
UP UP
UP UP
UP
DN DN
DN DN
DN
ADP-5.414
ADP-5.41
ADP-5.41
ADP-5.41
1
3
2
ADP-6.41
1
ADP-6.41 4
ADP-6.413
ADP-6.41
2
UNIT #19 (175 SFT)
UNIT TYPE - C
UNIT#20 (175 SFT)
UNIT TYPE - C
UNIT #21 (175 SFT)
UNIT TYPE - C
UNIT #22 (175 SFT)
UNIT TYPE - C
UNIT#23 (175 SFT)
UNIT TYPE - C
2%
4%
1%4%
4%3%
162'-9"
49.60 m
162'-3"
49.45 m
4%2%
2%2%
162'-3"
49.45 m
162'-3"
49.45 m
162'-3"
49.45 m
162'-3"
49.45 m162'-9"
49.60 m
162'-9"
49.60 m
162'-9"
49.60 m
162'-9"49.60 m
161'-7"
49.26 m
161'-9"
49.30 m
162'-0"
49.38 m
162'-2"
49.43 m
162'-2"
49.43 m
PWDR RM
FLEX RM
PWDR RM
FLEX RM
PWDR RM
FLEX RM
PWDR RM
FLEX RM
PWDR RM
FLEX RM
11' - 3 1/2"20' - 0"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
100' - 0"
8'
-
1
1
/
2
"
8' - 8"
6' - 6"
3'
-
9
"
20
'
-
0
"
3'
-
0
"
29
'
-
9
"
MECH RM
MECH RM MECH RM
MECH RM MECH RM
411 SF
(38.1 SM)
GARAGE
409 SF
(38.0 SM)
GARAGE
410 SF
(38.1 SM)
GARAGE
410 SF
(38.1 SM)
GARAGE
PATIO
PATIO PATIO
PATIO PATIO
20
'
-
0
"
161'-10"
49.32 m
162'-5"
49.50 m 162'-4"
49.47 m
162'-4"
49.47 m
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
161'-10"
49.32 m
1'
-
0
"
28
'
-
9
"
BALCONY LINE
ABOVE
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
19' - 1"
19' - 3"
ADP-5.414
ADP-5.41
ADP-5.41
ADP-5.41
1
3
2
ADP-6.41
1
ADP-6.41 4
ADP-6.413
ADP-6.41
2
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
UNIT#19 (545 SFT)
UNIT TYPE - C
UNIT #20 (545 SFT)
UNIT TYPE - C
UNIT#21 (545 SFT)
UNIT TYPE - C
UNIT #22 (545 SFT)
UNIT TYPE - C
UNIT #23 (545 SFT)
UNIT TYPE - C
DECK
F
DW
LIVING
DINING
STUDY
KITCHEN
PWDR RM
TV
F
DW
LIVING
DINING
STUDY
KITCHEN
PWDR RM
TV
11' - 3 1/2"20' - 0"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
19' - 10"40' - 0"40' - 2"
100' - 0"
DECK DECK
DECK DECK
1'
-
0
"
26
'
-
8
1
/
2
"
27
'
-
9
"
19' - 1"
26
'
-
8
"
3' - 0"
3' - 2"
5' - 0"
5'
-
0
1
/
2
"
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
3' - 0"
1'
-
0
"
3'
-
0
"
3'
-
0
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
01-05-2023
ADP-3.41
BUILDING-04 FLOOR PLANS
23638 TOWNHOUSES
722067
AR
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 FIRST FLOOR UN (19-23)
1/8" = 1'-0"2 SECOND FLOOR UN (19-23)
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
4
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DN DN
DN DN
ADP-5.414
ADP-5.41
ADP-5.41
ADP-5.41
1
3
2
ADP-6.41
1
ADP-6.41 4
ADP-6.413
ADP-6.41
2
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
BED RM
BATH
ENSUITE
M.BED RM
BED RM
W/D
BED RM
BATH
ENSUITE
M.BED RM
BED RM
W/D
UNIT#19 (580 SFT)
UNIT TYPE - C
UNIT #20 (580 SFT)
UNIT TYPE - C
UNIT #21 (580 SFT)
UNIT TYPE - C
UNIT#22 (580 SFT)
UNIT TYPE - C
UNIT#23 (580 SFT)
UNIT TYPE - C
11' - 3 1/2"20' - 0"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
100' - 0"
1'
-
0
"
10' - 2 1/2"
2'
-
6
"
10' - 2 1/2"
9'
-
6
"
5' - 0"
3'
-
0
"
3'
-
0
"
9'
-
0
"
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
1'
-
0
"
9'
-
1
1
1
/
2
"
11
'
-
7
1
/
2
"
ROOF LINE ABOVE
8' - 6"
3' - 0"
4' - 11 1/2"
7'
-
6
"
11' - 3 1/2"20' - 0"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
ADP-5.414
ADP-5.41
ADP-5.41
ADP-5.41
1
3
2
UNIT # 19
UNIT TYPE C
UNIT # 20
UNIT TYPE C
UNIT # 21
UNIT TYPE C
UNIT #22
UNIT TYPE C
UNIT # 23
UNIT TYPE C
ADP-6.41
1
ADP-6.41 4
ADP-6.413
ADP-6.41
2
9" / 12"7" / 12"
9" / 12"9" / 12"7" / 12"
9" / 12"9" / 12"7" / 12"
11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"11' - 3 1/2"8' - 8 1/2"2' - 0"
20' - 0"20' - 0"20' - 0"22' - 0"
34
'
-
4
"
BUILDING LINE BELOW
BUILDING LINE BELOW
2'
-
0
"
2'
-
0
"
2'
-
0
"
2'
-
0
"
2'
-
0
"
2'
-
0
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-3.42
BUILDING-04 FLOOR PLANS
23638 TOWNHOUSES
722067
AR
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 THIRD FLOOR PLAN (UNIT-19-23)
1/8" = 1'-0"2 ROOF PLAN (UNIT 19-23)
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
4
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
UPUP
UPUP
UPUP
DN DN
DNDN
DNDN
ADP-5.61 4
ADP-5.61
ADP-5.61
ADP-5.61
1
3
2
417 SF
(38.8 SM)
GARAGE
416 SF
(38.7 SM)
GARAGE
415 SF
(38.6 SM)
GARAGE415 SF
(38.6 SM)
GARAGE
PWDR RMPWDR RM
PWDR RMPWDR RM
PWDR RM
4.
9
%
4.
9
%
8.
2
%
2.
1
%
4.
0
%
0.
7
%
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
29
'
-
9
"
11' - 3 1/2"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
PATIOPATIO
PATIOPATIO
PATIOPATIO
161'-7"49.25 m
161'-7"
49.25 m
162'-1"
49.40 m
162'-1"49.40 m
162'-7"
49.55 m
162'-7"
49.55 m
162'-7"
49.55 m
160'-8"
48.98 m162'-0"
49.37 m
1'
-
0
"
28
'
-
9
"
ADP-6.61
1
ADP-6.614
ADP-6.61 3
ADP-6.61
2
FLEX RMFLEX RM
FLEX RM
UNIT #34 (170 SFT)
UNIT TYPE -C
UNIT #33 (171 SFT)
UNIT TYPE - C
UNIT #32 (171 SFT)
UNIT TYPE - C
UNIT #31 (170 SFT)
UNIT TYPE - C
UNIT #30 (170 SFT)
UNIT TYPE - C
UNIT #29 (170 SFT)
UNIT TYPE - C
3' - 0"7' - 5"
163'-1"
49.70 m
162'-1"
49.40 m
163'-1"
49.70 m
161'-7"49.26 m
161'-4"
49.17 m
162'-7"
49.55 m
162'-7"
49.55 m
PROPERTY LINE
FLEX RM
FLEX RMFLEX RM
416 SF
(38.6 SM)
GARAGE
415 SF
(38.6 SM)
GARAGE
163'-1"49.70 m
162'-1"49.40 m
159'-9"
48.68 m
162'-1"
49.40 m
161'-7"
49.24 m 161'-7"
49.24 m
161'-1"
49.09 m
161'-1"
49.09 m
4.
9
%
4.
9
%
4.
9
%
4.
9
%
9'
-
6
"
3' - 0"
ELECTRIC CLOSET
PWDR RM
162'-1"
49.40 m
4.
4
%
9.
1
%
19
'
-
1
1
1
/
2
"
19' - 1"
8' - 8"
8'
-
2
"
162'-1"
49.40 m
162'-1"
49.39 m
162'-7"49.55 m
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
5' - 11"2' - 0"3' - 6"
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
MECH.
ROOM
19' - 3"
ADP-5.61 4
ADP-5.61
ADP-5.61
ADP-5.61
1
3
2
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
27
'
-
8
1
/
2
"
11' - 3 1/2"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"8' - 10 1/2"
DECK
DECKDECK
DECKDECK
ADP-6.61
1
ADP-6.614
ADP-6.61 3
ADP-6.61
2
UNIT #34 (544 SFT)
UNIT TYPE - C
UNIT #33 (545 SFT)
UNIT TYPE - C
UNIT #32 (546 SFT)
UNIT TYPE - C
UNIT #31 (547 SFT)
UNIT TYPE - C
UNIT #30 (548 SFT)
UNIT TYPE - C
UNIT #29 (546 SFT)
UNIT TYPE - C
F
DW
LIVING
DINING
STUDY
KITCHEN
PWDR RM
TV
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
TV
DW
KITCHEN
PWDR RM
STUDY
DINING
LIVING
F
DW
LIVING
DINING
STUDY
KITCHEN
PWDR RM
TV
1'
-
0
"
26
'
-
8
1
/
2
"
1'
-
0
"
10
'
-
0
"
DECK
3' - 0"
39' - 10"40' - 4"39' - 10"
11
'
-
0
"
4'
-
0
"
5' - 0"
5'
-
0
"
5'
-
0
1
/
2
"
19' - 1"
26
'
-
7
1
/
2
"
3'
-
0
"
ROOF LINE BELOW
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
01-05-2023
ADP-3.61
BUILDING-06 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 FIRST FLOOR UN (29-34)
1/8" = 1'-0"2 SECOND FLOOR UN (29-34)
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
6
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DN
DNDN
DNADP-5.61 4
ADP-5.61
ADP-5.61
ADP-5.61
1
3
2
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
11' - 3 1/2"8' - 7"11' - 5 1/2"8' - 10 1/2"11' - 1 1/2"8' - 7"11' - 5 1/2"20' - 0"8' - 7"11' - 3 1/2"8' - 10 1/2"
ROOF LINE ABOVE
ADP-6.61
1
ADP-6.614
ADP-6.61 3
ADP-6.61
2
BED RM
BATH
ENSUITE
M.BED RMBED RM
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
M.BED RM
BED RM
ENSUITE
BED RM
BATH
W/D
BED RM
BATH
ENSUITE
M.BED RMBED RM
W/D
4' - 11 1/2"
3'
-
0
"
9'
-
1
1
1
/
2
"
5' - 0"
9'
-
6
"
10' - 2 1/2"
UNIT #34 (580 SFT)
UNIT TYPE - C
UNIT #33 (581 SFT)
UNIT TYPE - C
UNIT #32 (581 SFT)
UNIT TYPE - C
UNIT #31 (582 SFT)
UNIT TYPE - C
UNIT #30 (580 SFT)
UNIT TYPE - C
UNIT #29 (580 SFT)
UNIT TYPE - C
13
'
-
0
"
10
'
-
0
"
30
'
-
4
"
ROOF LINE ABOVE
8' - 10 1/2"11' - 3 1/2"8' - 7"11' - 1 1/2"8' - 10 1/2"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 5 1/2"8' - 7"11' - 3 1/2"
120' - 0"
2'
-
0
"
1'
-
0
"
27
'
-
4
"
2'
-
0
"
7'
-
6
"
8' - 6"
11
'
-
7
1
/
2
"
8' - 4"
3' - 0"
5' - 0"
11
'
-
1
0
1
/
2
"
2'
-
0
"
2'
-
0
"
ROOF LINE BELOW
ADP-5.61 4
ADP-5.61
ADP-5.61
ADP-5.61
1
3
2
WALL LINE BELOW
20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"20' - 0"
120' - 0"
ADP-6.61
1
ADP-6.614
ADP-6.61 3
ADP-6.61
2
UNIT #33 (581 SFT)
UNIT TYPE - C
UNIT #32 (581 SFT)
UNIT TYPE - C
UNIT #29 (580 SFT)
UNIT TYPE - C
34
'
-
4
"
2' - 0"
4'
-
0
"
2'
-
0
"
4'
-
0
"
3'
-
0
"
2'
-
0
"
10' - 8 1/2"11' - 3 1/2"8' - 8 1/2"20' - 0"11' - 3 1/2"8' - 8 1/2"20' - 0"11' - 3 1/2"8' - 8 1/2"
10' - 8 1/2"11' - 3 1/2"8' - 8 1/2"20' - 0"11' - 3 1/2"8' - 8 1/2"20' - 0"11' - 3 1/2"8' - 8 1/2"
4'
-
0
"
4'
-
0
"
11
'
-
0
"
4'
-
0
"
2'
-
0
"
2'
-
0
"
3'
-
0
"
3'
-
0
"
2'
-
0
"
9" / 12"9" / 12"9" / 12"
9" / 12"
2'
-
0
"
4'
-
0
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-3.62
BUILDING-06 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 THIRD FLOOR UN (29-34)
1/8" = 1'-0"2 ROOF PLAN UN (7-12)23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
6
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
UP UP UP UP
UP UP UP UP
UP UP
UP
DN DN DN DN
UP UPUP UP
ADP-5.914
ADP-5.91
ADP-5.91
ADP-5.91
1
3
2
2.
5
7
%
PATIO PATIO PATIO
ADP-6.91
1
ADP-6.913
ADP-6.914
ADP-6.91
2
YARD YARD
MECH. RM.
PATIO PATIO
YARDYARDYARD
MECH. RM.MECH. RM.
272 SF
(25.3 SM)
GARAGE 272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
272 SF
(25.2 SM)
GARAGE
2'
-
1
"
32
'
-
2
"
6'
-
6
"
20' - 2"12' - 3"4' - 7"12' - 3"4' - 7"12' - 3"4' - 7"12' - 3"4' - 7"19' - 10"
20' - 0"16' - 10"16' - 10"16' - 10"16' - 10"20' - 0"
19
'
-
1
1
"
3' - 6"
3' - 2"
3'
-
2
"
4'
-
0
"
417 SF
(38.8 SM)
GARAGE
FLEX RM PWDR RM
415 SF
(38.6 SM)
GARAGE
PWDR RM FLEX RM
PATIO
11' - 3 1/2"8' - 7"67' - 8"8' - 7"11' - 3 1/2"
3.
0
6
%
2.
5
7
%
2.
5
7
%
2.
6
0
%
2.
7
3
%
40
'
-
9
"
2'
-
1
"
3'
-
1
1
"
10
'
-
7
"
17
'
-
8
"
40
'
-
9
"
UNIT #47 (210 SFT)
UNIT TYPE - A
UNIT #48 (153 SFT)
UNIT TYPE - B
UNIT #49 (153 SFT)
UNIT TYPE - B1
UNIT #50 (153 SFT)
UNIT TYPE - B
UNIT #51 (151 SFT)
UNIT TYPE - B1
UNIT #52 (210 SFT)
UNIT TYPE - A
107' - 4"
10
'
-
7
"
19
'
-
1
1
1
/
2
"
10' - 2 1/2"
4' - 10"
3'
-
0
"
163'-10"
49.95 m
162'-10"
49.63 m
162'-5"
49.50 m
3.
1
6
%
162'-10"
49.63 m
162'-9"
49.60 m
1.
3
7
%
163'-0"
49.69 m
4.3
3
%
163'-2"
49.73 m
163'-4"
49.78 m
163'-4"
49.78 m
163'-6"
49.84 m
163'-10"
49.93 m
2.
4
1
%
4.
2
3
%
0.2
3
%
163'-9"49.92 m
163'-10"
49.93 m
164'-10"
50.25 m
164'-10"
50.25 m
164'-4"
50.10 m
164'-4"
50.10 m163'-10"
49.95 m
3' - 0"
9'
-
6
"
ELEC CLOSET
ROOF LINE ABOVE
163'-4"49.80 m
163'-4"
49.80 m
163'-10"
49.95 m 163'-10"
49.95 m 164'-4"
50.10 m
164'-4"
50.10 m
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
GARBAGE
BINS
BICYCLE
RACK
GARBAGE
BINS
BICYCLE
RACK
MECH.
ROOM
MECH.
ROOM
19' - 1"19' - 1"
ADP-5.914
ADP-5.91
ADP-5.91
ADP-5.91
1
3
2
ADP-6.91
1
ADP-6.913
ADP-6.914
ADP-6.91
2
DECK DECK DECK
DECK DECK
41
'
-
0
"
4'
-
9
"
32
'
-
2
"
2'
-
1
"
2'
-
0
"
19' - 10"67' - 8"19' - 10"
11' - 3 1/2"8' - 7"9' - 2 1/2"23' - 1 1/2"10' - 6 1/2"23' - 1 1/2"
1' - 8"
8' - 7"11' - 3 1/2"
20' - 0"16' - 10"16' - 10"16' - 10"16' - 10"20' - 0"
UNIT #47 (626 SFT)
UNIT TYPE - A
UNIT #48 (672 SFT)
UNIT TYPE - B
UNIT #49 (687 SFT)
UNIT TYPE - B1
UNIT #50 (672 SFT)
UNIT TYPE - B
UNIT #51 (687 SFT)
UNIT TYPE - B1
UNIT #52 (626 SFT)
UNIT TYPE - A
107' - 4"
DECK
FAMILY
KITCHEN
DINING
LIVING
BATH
LEDGE
FAMILY
KITCHEN
DINING
LIVING
BATH
LEDGE
KITCHEN
FAMILY
BATH
LIVING
DINING
LEDGE
KITCHEN
FAMILY
BATH
LIVING
DINING
LEDGE
LIVING
DINING STUDY
KITCHEN
PWDR RM
KITCHEN
PWDR RM
STUDY DINING
LIVING
31
'
-
1
"
19' - 1"
5' - 0"3' - 0"
5'
-
5
1
/
2
"
3' - 0"
16' - 1"
39
'
-
1
1
"
6' - 10 1/2"
8'
-
0
1
/
2
"
8' - 10"
2'
-
0
"
3' - 0 1/2"4' - 3"
2'
-
1
1
1
/
2
"
3' - 2"
WALL LINE ABOVE
32
'
-
2
"
2'
-
1
"
2'
-
0
"
4'
-
9
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
01-05-2023
ADP-3.91
BUILDING-09 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 FIRST FLOOR LEVEL (UN 47-51)
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
9
1/8" = 1'-0"2 SECOND FLOOR LEVEL (UN 47-51)
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
DN DNDN DN
ADP-5.914
ADP-5.91
ADP-5.91
ADP-5.91
1
3
2
ADP-6.91
1
ADP-6.913
ADP-6.914
ADP-6.91
2
42
'
-
9
"
6'
-
6
"
34
'
-
2
"
2'
-
1
"
11' - 3 1/2"8' - 7"13' - 7 1/2"20' - 1"13' - 7 1/2"20' - 4 1/2"8' - 7"11' - 3 1/2"
20' - 0"16' - 10"16' - 10"16' - 10"16' - 10"20' - 0"
11' - 3 1/2"8' - 7"9' - 2 1/2"23' - 1 1/2"10' - 6 1/2"23' - 1 1/2"1' - 8"8' - 7"11' - 3 1/2"
12' - 6 1/2"
10
'
-
4
"
11' - 2 1/2"
ROOF LINE ABOVE
ROOF LINE ABOVE
UNIT #47 (648 SFT)
UNIT TYPE - A
UNIT #48 (745 SFT)
UNIT TYPE - B
UNIT #49 (710 SFT)
UNIT TYPE - B1
UNIT #50 (744 SFT)
UNIT TYPE - B
UNIT #51 (712 SFT)
UNIT TYPE - B1
UNIT #52 (648 SFT)
UNIT TYPE - A
10' - 2 1/2"
107' - 4"
M.BED RM
ENSUITE
BED RM
BATH
BED RM
W/D
M.BED RM
ENSUITE
BED RM
BATH
BED RM
W/D
M.BED RM
W.I.C
ENSUITE
BATH
BED RM
BED RM
W/D
M.BED RM
W.I.C
ENSUITE
BATH
BED RM
BED RM
W/D
BED RM BED RM
BATH
ENSUITE
W.I.C
M.BED RM
W/D
BED RM BED RM
BATH
ENSUITE
W.I.C
M.BED RM
W/D
10
'
-
3
"
4' - 11 1/2"3' - 0"
5'
-
0
"
8' - 6"
8'
-
1
1
1
/
2
"
10' - 2 1/2"
10
'
-
2
1
/
2
"
6' - 6"
7'
-
0
"
9' - 5 1/2"9' - 9 1/2"
3' - 2"
3' - 4"
10
'
-
8
1
/
2
"
6'
-
0
"
3'
-
7
1
/
2
"
5'
-
0
"
8' - 10"
8' - 10"
10
'
-
4
1
/
2
"
3' - 4"
3' - 2"
12
'
-
3
"
10
'
-
9
"
9'
-
0
"
2'
-
0
"
16' - 10"
5.13 m
16' - 10"
5.13 m
3' - 11 1/4"
1.20 m
4' - 10 1/2"
1.49 m
ADP-5.914
ADP-5.91
ADP-5.91
ADP-5.91
1
3
2
ADP-6.91
1
ADP-6.913
ADP-6.914
ADP-6.91
2
BUILDING LINE BELOW
BUILDING LINE BELOW
20' - 0"16' - 10" 16' - 10"16' - 10" 16' - 10"20' - 0"
UNIT #47 (648 SFT)
UNIT TYPE - A
UNIT #48 (753 SFT)
UNIT TYPE - B
UNIT #49 (739 SFT)
UNIT TYPE - B1
UNIT #50 (755 SFT)
UNIT TYPE - B
UNIT #51 (739 SFT)
UNIT TYPE - B1
UNIT #52 (648 SFT)
UNIT TYPE - A
111' - 4"
34
'
-
2
"
12' - 0"9' - 0"11' - 2 1/2"10' - 2 1/2"13' - 3 1/2"13' - 3 1/2"10' - 2 1/2"11' - 2 1/2"9' - 0"12' - 0"
3'
-
7
"
2'
-
0
"
2'
-
0
"
4'
-
0
"
2' - 0"
2' - 0"
2'
-
0
"
4'
-
0
"
2'
-
0
"
4'
-
0
"
4'
-
0
"
2'
-
0
"
4'
-
0
"
2'
-
0
"
6'
-
6
"
38
'
-
2
"
4'
-
1
"
9" / 12"9" / 12"
9" / 12"
9" / 12"
9" / 12"
9" / 12"
9" / 12"9" / 12"
7" / 12"7" / 12"
2'
-
0
"
4'
-
0
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-3.92
BUILDING-09 FLOOR PLANS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 THIRD FLOOR LEVEL (UN 01-06)
1/8" = 1'-0"2 ROOF PLAN (UN 01-06)
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
9
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
ADP-6.101
2
ADP-5.101
ADP-6.1014
ADP-6.101
1
ADP-6.101 3
F
UP
996 SF
(92.5 SM)
AMENITY BLDG.
25' - 6 1/2"
ADP-5.101
2
ADP-5.101
1
ADP-5.101 3
LOUNGE
ROOF LINE
ABOVE
162'-1"
49.40 m
ENTRY
DW
RA
M
P
U
P
DN
39
'
-
0
"
6" X 18"
GLU LAM
H/C
WASH
4
7'
-
8
1
/
2
"
14' - 9 1/2"9' - 3 1/2"
7' - 7"
9'
-
5
"
ADP-6.101
2
ADP-5.101
ADP-6.1014
ADP-6.101
1
ADP-6.101 3
39
'
-
0
"
UP
GAMES
ROOM
996 SF
(92.5 SM)
AMENITY BLDG.
25' - 6 1/2"
ADP-5.101
2
ADP-5.101
1
ADP-5.101 3
LOUNGE
4
ROOF LINE BELOW
ADP-6.101
2
ADP-5.101
ADP-6.1014
ADP-6.101
1
ADP-6.101 3
ADP-5.101
2
ADP-5.101
1
ADP-5.101 3
4
6" / 12"6" / 12"
2' - 0"2' - 0"
3/16" = 1'-0"ADP-3.101
MAIN FLOOR PLAN1
3/16" = 1'-0"ADP-3.101
SECOND FLOOR PLAN2
DRAWING NO.
PROJECT NO. PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
2023-04-27 2:48:06 PM
ADP-3.101
AMENITY BUILDING
FLOOR PLANS
23638 TOWNHOUSES
722067
CY
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
3/16" = 1'-0"ADP-3.101
TOP OF ROOF3
236 ST
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
O U T D O O R
A M E N I T YAR EA 2 67 . 3 9
S Q . M
I N D O O RA M E N I T Y
AR E A ( 3S T O R E Y )
276 . 0 S Q. M
O U T D O O RA M E N I T Y
AR EA 2 57 . 5 4S Q . M
AMENITY
BUILDING
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
162' - 5"
49.50 m
162' - 5"
49.50 m162' - 3"
49.45 m
BUILDING 07 BUILDING 08 /
2
AD
P
-4.
0
1
/
2
AD
P
-4.
0
1
UNIT-A
UNIT-46UNIT-45UNIT-44UNIT-43UNIT-42UNIT-41UNIT-40UNIT-39UNIT-38UNIT-37UNIT-36UNIT-35
UNIT-AUNIT-A
UNIT-B
UNIT-A
UNIT-B
163' - 1"49.70 m162' - 5"
49.50 m
162' - 3"
49.45 m
162' - 3"
49.45 m
162' - 3"
49.45 m
162' - 1"
49.40 m
164' - 4"
50.10 m
164' - 1"
50.00 m163' - 10"
49.95 m
164' - 6"
50.15 m
FLEX ROOM
GARAGE
FLEX ROOM
168' - 6"
51.36 m
DEWDNEY TRUNK ROAD
EL
E
C
.
R
M
163' - 10"49.93 m
BUILDING 09
1.50 m
4' - 11"
6.00 m
19' - 8" ± [6M LANE]
30.56 m
100' - 3" ± [LOT-3]
LOT-3
163' - 10"
49.93 m
PR
O
P
E
R
T
Y
L
I
N
E
/
1
AD
P
-4.
0
1
/
1
AD
P
-4.
0
1
EXISITING LANESIDE
WALK
164' - 10"
50.25 m163' - 10"
49.95 m
UNIT-52UNIT-51UNIT-50UNIT-49UNIT-48UNIT-47
UNIT-A UNIT-A
UNIT-B
GARAGEGARAGE GARAGE GARAGE2.
7
6
m
9'
-
1
"
0.
3
2
m
1'
-
0
1
/
2
"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR DP SUBMISSION
3
26-04-2023
ADP-4.01
SITE SECTIONS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 STREET SECTION 1-1 PART A
1/8" = 1'-0"2 STREET SECTION 1-1 - PART B
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
09
BU
I
L
D
I
N
G
-
08
BU
I
L
D
I
N
G
-
07
BU
I
L
D
I
N
G
-
04
BU
I
L
D
I
N
G
-
03
BU
I
L
D
I
N
G
-
06
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
163' - 3"
49.75 m
SIDE
WALK
SIDE
WALK
162' - 7"
49.55 m
162' - 7"49.55 m 162' - 4"49.49 m
6.00 m
19' - 8" [6M DRIVE WAY]
1% SLOPE3% SLOPE
162' - 9"49.60 m
236 ST
162' - 1"
49.40 m
/
2
AD
P
-4.
0
2
/
2
AD
P
-4.
0
2
161' - 3"
49.15 m
162' - 6"
49.52 m 161' - 3"
49.15 m
1.52 m
5' - 0"
6M DRIVE WAY
GAGAGE GAGAGE
1.52 m
5' - 0"
BUILDING 02 BUILDING 03
INDOOR AMENITY
BUILDING
6.37 m
20' - 10 1/2" [EXISITNG ROAD]
DECK
UNIT-A UNIT-A
UNIT-08 UNIT-17
162' - 1"
49.40 m
162' - 1"
49.40 m 162' - 6"
49.52 m
162' - 5"
49.50 m
6M DRIVEWAY SIDE
WALK
/
1
AD
P
-4.
0
2
/
1
AD
P
-4.
0
2
3%
161' - 6"
49.23 m2%
1.50 m
4' - 11"
PR
O
P
E
R
T
Y
L
I
N
E
FLEX
RM.
GARAGEFLEX RM.
BUILDING 06
BUILDING 08
2.
7
6
m
9'
-
1
"
2.
7
6
m
9'
-
1
"
2.
3
5
m
7'
-
8
1
/
2
"
0.
3
2
m
1'
-
0
1
/
2
"
UNIT-A
UNIT-B
UNIT-30 UNIT-43
162' - 1"
49.40 m
161' - 11"
49.35 m 161' - 1"49.09 m 160' - 8"
48.98 m
162' - 3"49.45 m
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
1/8" = 1'-0"
ISSUED FOR DP SUBMISSION
3
26-04-2023
ADP-4.02
SITE SECTIONS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 STREET SECTION 2-2
1/8" = 1'-0"2 STREET SECTION 2-2 - Dependent 1
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
09
BU
I
L
D
I
N
G
-
08
BU
I
L
D
I
N
G
-
07
BU
I
L
D
I
N
G
-
04
BU
I
L
D
I
N
G
-
03
BU
I
L
D
I
N
G
-
06
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
BUILDING-02 BUILDING-01
5.50 m
18' - 0 1/2"
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
5.61 m
18' - 4 1/2"
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
3/32" = 1'-0"
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-4.03
STREET SCAPE VIEW
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
3/32" = 1'-0"1 STREET SCAPE VIEW 236 ST
0.10
01
0.20
01
0.30
01
ADP-4.03
01
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUT DOORAMENI TYAREA 257.54SQ.M
I NDOORAMENITYAREA (3STOREY)276.0 SQ.M
OUT DOORAMENI TYAREA 267.39SQ.M
BU
I
L
D
I
N
G
-
01
BU
I
L
D
I
N
G
-
02
BU
I
L
D
I
N
G
-
09
BU
I
L
D
I
N
G
-
08
BU
I
L
D
I
N
G
-
07
BU
I
L
D
I
N
G
-
03
23
6
S
T
R
E
E
T
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR LEVEL (UN 01-06)
(49.7)163' -0 11/16"
THIRD FLOOR LEVEL (UN 01-06)(55.71)182' -9 7/16"
U/S OF CLNG (UN 01-06)
(58.17)190' -10 3/16"
9'
-
7
1
/
2
"
2.
9
3
m
10
'
-
1
1
/
2
"
3.
0
8
m
8'
-
0
3
/
4
"
2.
4
6
m
8'
-
8
1
/
2
"
2.
6
6
m
PR
O
P
E
R
T
Y
L
I
N
E
TOP OF ROOF (UN 01-06)(60.83)199' -6 3/4"
36
'
-
6
"
11
.
1
3
m
SECOND FLOOR LEVEL (UN 01-06)(52.63)172' -8 1/16"
UNIT #01
UNIT TYPE B1
UNIT #02
UNIT TYPE B
UNIT #03
UNIT TYPE B1
UNIT #04
UNIT TYPE B
UNIT #05
UNIT TYPE B1
UNIT #06
UNIT TYPE B
162'-1"
49.40 m
162'-1"49.40 m 162'-1"
49.40 m 161'-7"
49.25 m
161'-7"
49.25 m 161'-7"
49.25 m
RD PWS3
9"
12"
9"
12"9"
12"
9"
12"
4"
/
1
2
"
FIRST FLOOR LEVEL (UN 01-06)
(49.7)163' -0 11/16"
THIRD FLOOR LEVEL (UN 01-06)(55.71)182' -9 7/16"
U/S OF CLNG (UN 01-06)
(58.17)190' -10 3/16"
8'
-
8
1
/
2
"
2.
6
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
TOP OF ROOF (UN 01-06)(60.83)199' -6 3/4"
36
'
-
6
"
11
.
1
3
m
SECOND FLOOR LEVEL (UN 01-06)(52.63)172' -8 1/16"
UNIT #06
UNIT TYPE B
UNIT #05
UNIT TYPE B1
UNIT #04
UNIT TYPE B
UNIT #03
UNIT TYPE B1
UNIT #02
UNIT TYPE B
UNIT #01
UNIT TYPE B
TR1 P
163'-1"
49.70 m
163'-1"
49.70 m 163'-1"
49.70 m
162'-7"
49.55 m
162'-7"
49.55 m 162'-7"
49.55 m
9"
12"
9"
12"
9"
12"
9"
12"
4"
/
1
2
"
FIRST FLOOR LEVEL (UN 01-06)(49.7)163' -0 11/16"
THIRD FLOOR LEVEL (UN 01-06)
(55.71)182' -9 7/16"
U/S OF CLNG (UN 01-06)(58.17)190' -10 3/16"
8'
-
8
1
/
2
"
2.
6
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
TOP OF ROOF (UN 01-06)
(60.83)199' -6 3/4"
36
'
-
6
"
11
.
1
3
m
SECOND FLOOR LEVEL (UN 01-06)
(52.63)172' -8 1/16"
161'-9"
49.30 m
161'-7"
49.25 m
UNIT #06
UNIT TYPE B
C2 WS3GRLS CE
FIRST FLOOR LEVEL (UN 01-06)(49.7)163' -0 11/16"
THIRD FLOOR LEVEL (UN 01-06)
(55.71)182' -9 7/16"
U/S OF CLNG (UN 01-06)(58.17)190' -10 3/16"
8'
-
8
1
/
2
"
2.
6
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
TOP OF ROOF (UN 01-06)
(60.83)199' -6 3/4"
36
'
-
6
"
11
.
1
3
m
SECOND FLOOR LEVEL (UN 01-06)
(52.63)172' -8 1/16"
161'-3"
49.16 m
162'-1"49.40 m
UNIT #01
UNIT TYPE B1
LSF WS3FA
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
BLACK /WHITE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-5.11
BUILDING-01 ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION
1/8" = 1'-0"3 NORTH ELEVATION
1/8" = 1'-0"4 SOUTH ELEVATION
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
1
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR UN (7-12)(49.6)162' -8 3/4"
SECOND FLOOR UN (7-12)
(52.63)172' -8 1/8"
THIRD FLOOR UN (7-12)
(55.72)182' -9 1/2"
U/S OF CLNG UN (7-12)(58.17)190' -10 1/4"
TOP OF ROOF UN (7-12)(60.63)198' -11 1/8"
9'
-
1
1
1
/
2
"
3.
0
3
m
10
'
-
1
1
/
2
"
3.
0
8
m
8'
-
0
3
/
4
"
2.
4
6
m
8'
-
1
"
2.
4
6
m
36
'
-
2
1
/
2
"
11
.
0
3
m
3"
12"
3"
12"
UNIT #07
UNIT TYPE A
UNIT #08
UNIT TYPE A
UNIT#09
UNIT TYPE A
UNIT #10
UNIT TYPE A
UNIT #11
UNIT TYPE A
UNIT #12
UNIT TYPE A
C2 WS1 LS RDWS3FGR
162'-1"
49.40 m
162'-1"
49.40 m
162'-7"
49.55 m
162'-7"
49.55 m
162'-7"
49.55 m162'-1"
49.40 m
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
FIRST FLOOR UN (7-12)
(49.6)162' -8 3/4"
SECOND FLOOR UN (7-12)(52.63)172' -8 1/8"
THIRD FLOOR UN (7-12)(55.72)182' -9 1/2"
U/S OF CLNG UN (7-12)
(58.17)190' -10 1/4"
TOP OF ROOF UN (7-12)
(60.63)198' -11 1/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
1
1
/
2
"
3.
0
3
m
36
'
-
2
1
/
2
"
11
.
0
3
m
UNIT #07
UNIT TYPE A
UNIT #08
UNIT TYPE A
UNIT#09
UNIT TYPE A
UNIT #10
UNIT TYPE A
UNIT #11
UNIT TYPE A
UNIT #12
UNIT TYPE A
163'-1"
49.70 m 163'-1"
49.70 m
163'-1"
49.70 m 162'-3"
49.45 m
162'-3"49.45 m 162'-3"
49.45 m
C2 PLSCE
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
FIRST FLOOR UN (7-12)(49.6)162' -8 3/4"
SECOND FLOOR UN (7-12)
(52.63)172' -8 1/8"
THIRD FLOOR UN (7-12)
(55.72)182' -9 1/2"
U/S OF CLNG UN (7-12)(58.17)190' -10 1/4"
TOP OF ROOF UN (7-12)
(60.63)198' -11 1/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
1
1
/
2
"
3.
0
3
m
36
'
-
2
1
/
2
"
11
.
0
3
m
UNIT #12
UNIT TYPE A162'-6"49.52 m
163'-1"49.70 m
C1GR TR1TR2LS FL
FIRST FLOOR UN (7-12)(49.6)162' -8 3/4"
SECOND FLOOR UN (7-12)
(52.63)172' -8 1/8"
THIRD FLOOR UN (7-12)
(55.72)182' -9 1/2"
U/S OF CLNG UN (7-12)(58.17)190' -10 1/4"
TOP OF ROOF UN (7-12)
(60.63)198' -11 1/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
1
1
/
2
"
3.
0
3
m
36
'
-
2
1
/
2
"
11
.
0
3
m
UNIT #07
UNIT TYPE A162'-3"
49.45 m
C3 WS1 C1 TR2F
MATERIAL LEGEND :
COLORMATERIAL
FASCIA
GR GUARD/RAILING
FL FLASHING
FA
WHITE
BLACK
WHITE
ASPHALT SHINGLES AS DARK GREY
RD ROLL-UP DOOR
DOORS BLACK
GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
C1 8" HARDI SIDING GREENBLACK
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
C3 8" HARDI SIDING CASTLEGATE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-5.21
BUILDING-02 ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION
1/8" = 1'-0"3 NORTH ELEVATION
1/8" = 1'-0"4 SOUTH ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
2
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR UN (19-23)(49.6)162' -8 3/4"
SECOND FLOOR UN (19-23)
(52.6)172' -6 15/16"
THIRD FLOOR PLAN (UNIT-19-23)
(55.69)182' -8 5/16"
U/S OF CLNG UN (23-19)
(58.14)190' -9 1/16"
TOP OF ROOF UN (23-19)(60.6)198' -9 15/16"
9'
-
1
0
1
/
4
"
3.
0
0
m
10
'
-
1
1
/
2
"
3.
0
8
m
8'
-
0
3
/
4
"
2.
4
6
m
8'
-
1
"
2.
4
6
m
36
'
-
1
1
/
4
"
11
.
0
0
m
C2 TR1 F
UNIT #23
UNIT TYPE C
UNIT #22
UNIT TYPE C
UNIT #21
UNIT TYPE C
UNIT #20
UNIT TYPE C
UNIT #19
UNIT TYPE C
162'-3"
49.45 m
162'-3"
49.45 m 162'-3"
49.45 m
162'-3"
49.45 m 162'-3"
49.45 m
WS1 C1
7"
12"
9"
12"
7"
12"
9"
12"
7"
12"
9"
12"
FIRST FLOOR UN (19-23)(49.6)162' -8 3/4"
SECOND FLOOR UN (19-23)
(52.6)172' -6 15/16"
THIRD FLOOR PLAN (UNIT-19-23)
(55.69)182' -8 5/16"
U/S OF CLNG UN (23-19)(58.14)190' -9 1/16"
TOP OF ROOF UN (23-19)(60.6)198' -9 15/16"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
0
1
/
4
"
3.
0
0
m
36
'
-
1
1
/
4
"
11
.
0
0
m
GRLS TR2
F
P
162'-2"49.43 m162'-1"49.40 m161'-11"
49.35 m161'-9"
49.30 m
161'-7"
49.26 m
RD
UNIT #23
UNIT TYPE C
UNIT #22
UNIT TYPE C
UNIT #21
UNIT TYPE C
UNIT #20
UNIT TYPE C
UNIT #19
UNIT TYPE C
9"
12"
7"
12"9"
12"
7"
12"
9"
12"
7"
12"
FIRST FLOOR UN (19-23)(49.6)162' -8 3/4"
SECOND FLOOR UN (19-23)
(52.6)172' -6 15/16"
THIRD FLOOR PLAN (UNIT-19-23)
(55.69)182' -8 5/16"
U/S OF CLNG UN (23-19)(58.14)190' -9 1/16"
TOP OF ROOF UN (23-19)(60.6)198' -9 15/16"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
0
1
/
4
"
3.
0
0
m
36
'
-
1
1
/
4
"
11
.
0
0
m
TR1
UNIT #19
UNIT TYPE C
162'-3"
49.45 m
CE
FIRST FLOOR UN (19-23)(49.6)162' -8 3/4"
SECOND FLOOR UN (19-23)
(52.6)172' -6 15/16"
THIRD FLOOR PLAN (UNIT-19-23)
(55.69)182' -8 5/16"
U/S OF CLNG UN (23-19)(58.14)190' -9 1/16"
TOP OF ROOF UN (23-19)(60.6)198' -9 15/16"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
1
0
1
/
4
"
3.
0
0
m
36
'
-
1
1
/
4
"
11
.
0
0
m
TR1
UNIT #23
UNIT TYPE C
162'-4"
49.47 m
CE
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C1 8" HARDI SIDING HIGH REFLECTIVE
WHITE
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-5.41
BUILDING-04 ELEVATIONS
23638 TOWNHOUSES
722067
AR
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION
1/8" = 1'-0"3 NORTH ELEVATION
1/8" = 1'-0"4 SOUTH ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
4
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR UN (29-34)
(49.3)161' -9"
SECOND FLOOR UN (29-34)(52.41)171' -11 3/8"
THIRD FLOOR UN (29-34)(55.49)182' -0 3/4"
U/S OF CLNG UN (29-34)
(57.95)190' -1 1/2"
TOP OF ROOF UN (29-34)
(60.41)198' -2 3/8"
10
'
-
2
1
/
2
"
3.
1
1
m
10
'
-
1
1
/
2
"
3.
0
8
m
8'
-
0
3
/
4
"
2.
4
6
m
8'
-
1
"
2.
4
6
m
36
'
-
5
1
/
2
"
11
.
1
1
m
161'-1"
49.09 m
161'-1"
49.09 m 161'-6"
49.23 m
161'-7"
49.24 m
162'-1"
49.39 m
162'-1"
49.39 m
UNIT #29
UNIT TYPE - C
UNIT # 30
UNIT TYPE - C
UNIT # 31
UNIT TYPE -C
UNIT # 32
UNIT TYPE - C
UNIT # 33
UNIT TYPE - C
UNIT # 34
UNIT TYPE - C
RD FP ASWS3
7"
12"
9"
12"
7"
12"
9"
12"
9"
12"
7"
12"
FIRST FLOOR UN (29-34)
(49.3)161' -9"
SECOND FLOOR UN (29-34)(52.41)171' -11 3/8"
THIRD FLOOR UN (29-34)(55.49)182' -0 3/4"
U/S OF CLNG UN (29-34)(57.95)190' -1 1/2"
TOP OF ROOF UN (29-34)
(60.41)198' -2 3/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
10
'
-
2
1
/
2
"
3.
1
1
m
36
'
-
5
1
/
2
"
11
.
1
1
m
UNIT # 30
UNIT TYPE - C
UNIT # 31
UNIT TYPE -C
UNIT # 32
UNIT TYPE - C
UNIT # 33
UNIT TYPE - C
UNIT # 34
UNIT TYPE - C
UNIT # 29
UNIT TYPE - C
LS
WS1
162'-7"
49.55 m
162'-7"
49.55 m 162'-1"
49.40 m
162'-1"
49.40 m 161'-7"
49.25 m 161'-7"
49.25 m
9"
12"
7"
12"
9"
12"
7"
12"
7"
12"
9"
12"
7"
12"
9"
12"
FIRST FLOOR UN (29-34)(49.3)161' -9"
SECOND FLOOR UN (29-34)
(52.41)171' -11 3/8"
THIRD FLOOR UN (29-34)
(55.49)182' -0 3/4"
U/S OF CLNG UN (29-34)(57.95)190' -1 1/2"
TOP OF ROOF UN (29-34)(60.41)198' -2 3/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
10
'
-
2
1
/
2
"
3.
1
1
m
36
'
-
5
1
/
2
"
11
.
1
1
m
UNIT # 29
UNIT TYPE -C
C2CETR1 FL
161'-1"
49.09 m 160'-5"
48.90 m
161'-7"
49.25 m
7"
/
1
2
"
FIRST FLOOR UN (29-34)(49.3)161' -9"
SECOND FLOOR UN (29-34)
(52.41)171' -11 3/8"
THIRD FLOOR UN (29-34)
(55.49)182' -0 3/4"
U/S OF CLNG UN (29-34)(57.95)190' -1 1/2"
TOP OF ROOF UN (29-34)(60.41)198' -2 3/8"
8'
-
1
"
2.
4
6
m
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
10
'
-
2
1
/
2
"
3.
1
1
m
36
'
-
5
1
/
2
"
11
.
1
1
m
UNIT # 34
UNIT TYPE - C
WS1GR TR2
162'-7"
49.55 m162'-0"
49.39 m
162'-0"
49.37 m
FA
9"
/
1
2
"
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
WS3 HARDI WALL SHINGLES GREENBLACK
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-5.61
BUILDING-06 ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION
1/8" = 1'-0"3 SOUTH ELEVATION
1/8" = 1'-0"4 NORTH ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
6
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR LEVEL (UN 47-51)(50.1)164' -4 7/16"
THIRD FLOOR LEVEL (UN 01-06)(56.11)184' -1 3/16"
U/S OF CLNG (UN 01-06)
(58.57)192' -1 15/16"
9'
-
7
1
/
2
"
2.
9
3
m
10
'
-
1
1
/
2
"
3.
0
8
m
8'
-
0
3
/
4
"
2.
4
6
m
SECOND FLOOR LEVEL (UN 47-51)(53.03)173' -11 13/16"
C2FPRD1
UNIT #47
UNIT TYPE A
UNIT #48
UNIT TYPE B
UNIT #49
UNIT TYPE B1
UNIT #50
UNIT TYPE B
UNIT #51
UNIT TYPE B1
UNIT #52
UNIT TYPE A
163'-10"
49.93 m
163'-10"
49.93 m 163'-4"49.78 m 163'-4"
49.78 m 162'-10"49.63 m 162'-10"
49.63 m
CE
TOP OF ROOF (UN 01-06)(61.07)200' -4 1/2"
8'
-
2
1
/
2
"
2.
5
0
m
36
'
-
0
"
10
.
9
7
m
RD
9"
12"
9"
12"
9"
12"
9"
12"
7"
12"
7"
12"
9"
12"
9"
12"
9"
12"
9"
12"
FIRST FLOOR LEVEL (UN 47-51)
(50.1)164' -4 7/16"
THIRD FLOOR LEVEL (UN 01-06)(56.11)184' -1 3/16"
U/S OF CLNG (UN 01-06)
(58.57)192' -1 15/16"
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
SECOND FLOOR LEVEL (UN 47-51)(53.03)173' -11 13/16"
LS TR1TR2
UNIT #47
UNIT TYPE A
UNIT #48
UNIT TYPE B
UNIT #49
UNIT TYPE B1
UNIT #50
UNIT TYPE B
UNIT #51
UNIT TYPE B1
UNIT #52
UNIT TYPE A
163'-4"
49.80 m
163'-4"
49.80 m 163'-10"
49.95 m
163'-10"
49.95 m
164'-4"
50.10 m
164'-4"50.10 m
TOP OF ROOF (UN 01-06)(61.07)200' -4 1/2"
8'
-
2
1
/
2
"
2.
5
0
m
36
'
-
0
"
10
.
9
7
m
WS2
9"
12"
9"
12"
9"
12"
9"
12"
7"
12"
7"
12"
9"
12"
9"
12"
9"
12"
9"
12"
FIRST FLOOR LEVEL (UN 47-51)(50.1)164' -4 7/16"
THIRD FLOOR LEVEL (UN 01-06)
(56.11)184' -1 3/16"
U/S OF CLNG (UN 01-06)
(58.57)192' -1 15/16"
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
GR
SECOND FLOOR LEVEL (UN 47-51)
(53.03)173' -11 13/16"
LS
UNIT #47
UNIT TYPE A
162'-5"
49.50 m
163'-4"
49.80 m
162'-10"
49.63 m
TOP OF ROOF (UN 01-06)(61.07)200' -4 1/2"
8'
-
2
1
/
2
"
2.
5
0
m
36
'
-
0
"
10
.
9
7
m
FL
FIRST FLOOR LEVEL (UN 47-51)(50.1)164' -4 7/16"
THIRD FLOOR LEVEL (UN 01-06)
(56.11)184' -1 3/16"
U/S OF CLNG (UN 01-06)
(58.57)192' -1 15/16"
8'
-
0
3
/
4
"
2.
4
6
m
10
'
-
1
1
/
2
"
3.
0
8
m
9'
-
7
1
/
2
"
2.
9
3
m
SECOND FLOOR LEVEL (UN 47-51)
(53.03)173' -11 13/16"
UNIT #52
UNIT TYPE A164'-4"50.10 m 163'-10"
49.93 m
TOP OF ROOF (UN 01-06)(61.07)200' -4 1/2"
8'
-
2
1
/
2
"
2.
5
0
m
36
'
-
0
"
10
.
9
7
m
C2
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
WS2 HARDI WALL SHINGLES HIGH REFLECTIVE WHITE
BLACK /WHITE
C3 8" HARDI SIDING CASTLEGATE
RD1 ROLL-UP DOOR GREY
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-5.91
BUILDING-09 ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST ELEVATION
1/8" = 1'-0"2 WEST ELEVATION
1/8" = 1'-0"3 NORTH ELEVATION
1/8" = 1'-0"4 SOUTH ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
9
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FIRST FLOOR
(49.4)162' -1"
SECOND FLOOR
(53.06)174' -1"
12
'
-
0
"
3.
6
6
m
UNDER SIDE OF ROOF
(56.72)186' -1"
C1
12
'
-
0
"
3.
6
6
m
161'-1"
49.10 m
??
TOP OF ROOF
(59.17)194' -1 1/2"
8'
-
0
3
/
4
"
2.
4
6
m
32
'
-
0
3
/
4
"
9.
7
7
m
161'-5"
49.20 m
FIRST FLOOR
(49.4)162' -1"
SECOND FLOOR
(53.06)174' -1"
P
12
'
-
0
"
3.
6
6
m
UNDER SIDE OF ROOF
(56.72)186' -1"
FL
12
'
-
0
"
3.
6
6
m
160'-9"
49.00 m
161'-1"
49.10 m
TOP OF ROOF
(59.17)194' -1 1/2"
8'
-
0
3
/
4
"
2.
4
6
m
32
'
-
0
3
/
4
"
9.
7
7
m
162'-1"
49.40 m
FIRST FLOOR
(49.4)162' -1"
SECOND FLOOR
(53.06)174' -1"
12
'
-
0
"
3.
6
6
m
UNDER SIDE OF ROOF
(56.72)186' -1"
12' - 0"
3.66 m
161'-5"
49.20 m 161'-1"
49.10 m
?
C1
6"
/
1
2
"
TOP OF ROOF
(59.17)194' -1 1/2"
8' - 0 3/4"
2.46 m
32' - 0 3/4"
9.77 m
FIRST FLOOR
(49.4)162' -1"
SECOND FLOOR
(53.06)174' -1"
UNDER SIDE OF ROOF
(56.72)186' -1"
160'-9"
49.00 m
161'-1"
49.10 m
12' - 0"
3.66 m
12' - 0"
3.66 m
?
6"
/
1
2
"
TOP OF ROOF
(59.17)194' -1 1/2"
8' - 0 3/4"
2.46 m
32' - 0 3/4"
9.77 m
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
FA
WHITE
BLACK
DOORS BLACK
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
P
WINDOWS BLACK
F
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C1 4" HARDI SIDING
HARDI PLANKHP1 GREY
CASTLEGATE
DRAWING NO.
PROJECT NO. PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
2023-04-27 2:48:06 PM
ADP-5.101
AMENITY BUILDING
ELEVATIONS
23638 TOWNHOUSES
722067
GR
AG
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
3/16" = 1'-0"ADP-5.101
NORTH ELEVATION1
3/16" = 1'-0"ADP-5.101
SOUTH ELEVATION2
3/16" = 1'-0"ADP-5.101
WEST ELEVATION3
3/16" = 1'-0"ADP-5.101
EAST ELEVATION4
236 ST
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
O U T D O O RA M E N I T YAR EA 2 67 . 3 9
S Q . M
I N D O O R
A M E N I T Y
AR E A ( 3S T O R E Y )
276 . 0 S Q. M
O U T D O O R
A M E N I T Y
AR EA 2 57 . 5 4S Q . M
AMENITY
BUILDING
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
BLACK /WHITE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-6.11
BUILDING-01 COLORED
ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST COLORED ELEVATION
1/8" = 1'-0"2 WEST COLORED ELEVATION
1/8" = 1'-0"3 NORTH COLORED ELEVATION
1/8" = 1'-0"4 SOUTH COLORED ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
1
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
MATERIAL LEGEND :
COLORMATERIAL
FASCIA
GR GUARD/RAILING
FL FLASHING
FA
WHITE
BLACK
WHITE
ASPHALT SHINGLES AS DARK GREY
RD ROLL-UP DOOR
DOORS BLACK
GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
C1 8" HARDI SIDING GREENBLACK
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
C3 8" HARDI SIDING CASTLEGATE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-6.21
BUILDING-02 COLORED
ELEVATION
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST COLORED ELEVATION
1/8" = 1'-0"2 WEST COLORED ELEVATION
1/8" = 1'-0"3 SOUTH COLORED ELEVATION
1/8" = 1'-0"4 NORTH COLORED ELEVATION
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
2
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C1 8" HARDI SIDING HIGH REFLECTIVE
WHITE
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-6.41
BUILDING-04 COLORED
ELEVATION
23638 TOWNHOUSES
722067
AR
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST COLORED ELEVATION
1/8" = 1'-0"2 WEST COLORED ELEVATION
1/8" = 1'-0"3 SOUTH COLORED ELEVATION
1/8" = 1'-0"4 NORTH COLORED ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.MBU
I
L
D
I
N
G
0
4
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
WS3 HARDI WALL SHINGLES GREENBLACK
BLACK /WHITE
WS1 HARDI WALL SHINGLES CASTLEGATE
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-6.61
BUILDING-06 COLORED
ELEVATION
23638 TOWNHOUSES
722067
VS
CY
23638,DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST COLORED ELEVATION
1/8" = 1'-0"2 WEST COLORED ELEVATION
1/8" = 1'-0"3 NORTH COLORED ELEVATION
1/8" = 1'-0"4 SOUTH COLORED ELEVATION
236
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
6
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
RD ROLL-UP DOOR
FA
WHITE
BLACK
DOORS BLACK
GREY
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
TR2 TRIM WHITE
P
WINDOWSF
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
WS3 HARDI WALL SHINGLES GREENBLACK
C2 8" HARDI SIDING HIGH REFLECTIVE
WHITE
WS2 HARDI WALL SHINGLES HIGH REFLECTIVE WHITE
BLACK /WHITE
C3 8" HARDI SIDING CASTLEGATE
RD1 ROLL-UP DOOR GREY
DRAWING NO.
PROJECT NO.PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
26-04-2023
ADP-6.91
BUILDING-09 COLORED
ELEVATIONS
23638 TOWNHOUSES
722067
VS
CY
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
1/8" = 1'-0"1 EAST COLORED ELEVATION
1/8" = 1'-0"2 WEST COLORED ELEVATION
1/8" = 1'-0"3 NORTH COLORED ELEVATION
1/8" = 1'-0"4 SOUTH COLORED ELEVATION
23
6
S
T
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
OUTDOORAMENITYAREA 267.39SQ.M
INDOORAMENITYAR EA ( 3STOREY)276.0 SQ.M
OUTDOORAMENITYAREA 257.54SQ.M
BU
I
L
D
I
N
G
0
9
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
FASCIA
GR GUARD/RAILING
FL FLASHING
MATERIAL LEGEND :
COLORMATERIAL
FA
WHITE
BLACK
DOORS BLACK
WHITE
ASPHALT SHINGLES AS DARK GREY
TR1 TRIM GREY
P
WINDOWS BLACK
F
COLUMNSCE GREY
LS LEDGE STONE CLADDING BRICK DARK
C1 4" HARDI SIDING
HARDI PLANKHP1 GREY
CASTLEGATE
DRAWING NO.
PROJECT NO. PLOT DATE
SCALE
DRAWING ISSUE
DRAWING TITLE
PROJECT
THIS DRAWING, AS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF KASIAN
ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD, THE COPYRIGHT IN THE SAME
BEING RESERVED TO THEM. NO REPRODUCTION IS ALLOWED WITHOUT THE
PERMISSION OF KASIAN ARCHITECTURE INTERIOR DESIGN AND PLANNING LTD AND
WHEN MADE MUST BEAR ITS NAME.
THIS DRAWING IS NOT TO BE SCALED. THE CONTRACTOR IS TO VERIFY DIMENSIONS
AND DATA NOTED HEREIN WITH THE CONDITIONS ON SITE AND IS RESPONSIBLE FOR
REPORTING ANY DISCREPANCY TO KASIAN ARCHITECTURE INTERIOR DESIGN AND
PLANNING LTD FOR ADJUSTMENT.
SEAL
PERMIT STAMP
CONSULTANT
DRAWN
REVIEWED
REVISION
1500 West Georgia Street, Suite 1685Kasian Architecture
Interior Design
and Planning Ltd www.kasian.com
Vancouver, BC Canada V6G 2Z6
T 604 683 4145 F 604 683 2827
As indicated
ISSUED FOR ADP SUBMISSION
4
2023-04-27 2:48:08 PM
ADP-6.101
AMENITY BUILDING
COLORED
ELEVATIONS
23638 TOWNHOUSES
722067
GR
AG
23638 DEWDNEY TRUNK RD,MAPLE RIDGE,
B.C.CANADA
3/16" = 1'-0"ADP-6.101
COLOURED SOUTH ELEVATION2
3/16" = 1'-0"ADP-6.101
COLORED NORTH ELEVATION1
3/16" = 1'-0"ADP-6.101
COLORED WEST ELEVATION3
3/16" = 1'-0"ADP-6.101
COLORED EAST ELEVATION4
236 ST
DEWDNEY TRUNK ROAD
BUILDING-01
BUILDING-02 BUILDING-03
BUILDING-04 BUILDING-05
BUILDING-06
BUILDING-07
BUILDING-08
BUILDING-09
O U T D O O R
A M E N I T YAR EA 2 67 . 3 9
S Q . M
I N D O O RA M E N I T Y
AR E A ( 3S T O R E Y )
276 . 0 S Q. M
O U T D O O RA M E N I T Y
AR EA 2 57 . 5 4S Q . M
AMENITY
BUILDING
REV. YYYY-MM-DD REVISION / DRAWING ISSUE REVIEW
1 2022 JAN 10 PRELIMINARY DESIGN LAYOUT
2 2022 SEP 27 ISSUED FOR DP SUBMISSION
3 2022 NOV 22 ISSUED FOR DP SUBMISSION
4 2023 APR 17 ISSUED FOR ADP SUBMISSION
PERMEABLE PAVER
VISITOR STALLS
ABBOTSFORD CONCRETE
AQUAPAVE, HERRINGBONE
COLOUR: NATURAL
PERMEABLE PAVER
VISITOR STALLS
ABBOTSFORD CONCRETE
AQUAPAVE, HERRINGBONE
COLOUR: NATURAL
PICNIC TABLES UNDER
METAL AND TIMBER ARBOR
CORNUS KOUSA
X NUTTALLII
'STARLIGHT'
PICEA GLAUCA 'PENDULA'
MAGNOLIA
x 'GALAXY'
SEQUOIADENDRON GIGANTEUM
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
BARKMAN BROADWAY PAVERS; ASH AND CHARCOAL
RAISED CROSSWALK
EXISTING TREES
TO BE RETAINED
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
LIFESPACE RAISED GARDEN PLOTS
CEDARSHED GARDEN SHED
WISHBONE CITYSCAPE BENCH
MUTUAL MATERIALS
VANCOUVER BAY SLAB; CHARCOAL
HAUSER NOVA LOUNGE CHAIR
OPEN LAWN
CARPINUS BETULUS 'FASTIGIATA'
ACER CIRCINATUM KOMPAN CRAWLING PYRAMID
VISITOR BIKE PARKING
ACER RUBRUM 'RED SUNSET'
GROUP SEATING
BARBECUE AREA
WITH MOVEABLE
TABLES AND CHAIRS
NATURE PLAY AREA
WITH FIBAR
SAFETY SURFACE
LARGE BOULDERS
FOR INFORMAL SEATING
KOMPAN
SPINNER PLATE
BALANCE LOGS AND STEPPERS
PICEA OMORIKA
PSEUDOTSUGA MENZIESIISTYRAX JAPONICUS 'PINK CHIMES'
BENCH
BENCH
23
6
S
T
R
E
E
T
METAL FENCE
AND GATE
PERIMETER
FENCE
LANE
CORNUS
KOUSA
'SATOMI'
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
PING PONG
STRUCTURAL
SOIL
UNDER
PAVEMENT
STRUCTURAL
SOIL
UNDER
PAVEMENT
100 20m5 40m
PMG PROJECT NUMBER:22-139
PLANTED SIZE / REMARKSCOMMON NAMEBOTANICAL NAME
PLANT SCHEDULE
KEY QTY
TREE
12 ACER CIRCINATUM VINE MAPLE 1.5M HT; B&B; 3 STEM CLUMP
9 ACER PLATANOIDES 'CRIMSON SENTRY'COLUMNAR CRIMSON SENTRY MAPLE 6CM CAL; B&B
5 CARPINUS BETULUS 'FASTIGIATA'PYRAMIDAL EUROPEAN HORNBEAM 5CM CAL; B&B
18 CORNUS KOUSA X NUTTALLII 'STARLIGHT'STARLIGHT HYBRID DOGWOOD 6CM CAL; 1.5M STD; B&B
13 MAGNOLIA x 'GALAXY'MAGNOLIA 5CM CAL; 1.5M STD
25 PICEA GLAUCA 'PENDULA'WEEPING WHITE SPRUCE 2.5M HT; B&B
10 PICEA OMORIKA SERBIAN SPRUCE 3M HT; B&B
3 PSEUDOTSUGA MENZIESII DOUGLAS FIR 3M HT; B&B
1 SEQUOIADENDRON GIGANTEUM GIANT REDWOOD 5M HT; B&B
21 STYRAX JAPONICUS 'PINK CHIMES'PINK FLOWERED JAPANESE SNOWBELL 5CM CAL; 1.5M STD; B&B
NOTES: * PLANT SIZES IN THIS LIST ARE SPECIFIED ACCORDING TO THE BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD, LATEST EDITION. CONTAINER SIZES
SPECIFIED AS PER CNLA STANDARD. BOTH PLANT SIZE AND CONTAINER SIZE ARE THE MINIMUM ACCEPTABLE SIZES. * REFER TO SPECIFICATIONS FOR DEFINED CONTAINER
MEASUREMENTS AND OTHER PLANT MATERIAL REQUIREMENTS. * SEARCH AND REVIEW: MAKE PLANT MATERIAL AVAILABLE FOR OPTIONAL REVIEW BY LANDSCAPE ARCHITECT AT
SOURCE OF SUPPLY. AREA OF SEARCH TO INCLUDE LOWER MAINLAND AND FRASER VALLEY. * SUBSTITUTIONS: OBTAIN WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT
PRIOR TO MAKING ANY SUBSTITUTIONS TO THE SPECIFIED MATERIAL. UNAPPROVED SUBSTITUTIONS WILL BE REJECTED. ALLOW A MINIMUM OF FIVE DAYS PRIOR TO DELIVERY
FOR REQUEST TO SUBSTITUTE. SUBSTITUTIONS ARE SUBJECT TO BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD - DEFINITION OF CONDITIONS OF
AVAILABILITY. * ALL LANDSCAPE MATERIAL AND WORKMANSHIP MUST MEET OR EXCEED BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD LATEST EDITION. * ALL
PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. * BIO-SOLIDS NOT PERMITTED IN GROWING MEDIUM UNLESS AUTHORIZED BY LANDSCAPE
ARCHITECT.
KOMPAN ROBINIA CRAWLING PYRAMID KOMPAN ROBINIA SPINNER PLATE NATURE PLAY PRECEDENT IMAGE
LIFESPACE RAISED GARDEN PLOTS HAUSER NOVA LOUNGE CHAIR WISHBONE CITYSCAPE BENCH
LIFESPACE HARVEST TABLE WISHBONE LARSON PICNIC TABLE MAGLIN FORO TABLES AND CHARS
BARKMAN BROADWAY PAVERS MUTUAL MATERIALS VANCOUVER BAY SLABS
18 CORNUS KOUSA 'SATOMI'PINK KOUSA DOGWOOD 2.5M HT; B&B
LANDSCAPE PLAN
TOWNHOUSE DEVELOPMENT - 23638 DEWDNEY TRUNK ROAD, MAPLE RIDGE, BC
PERMEABLE PAVER
VISITOR STALLS
ABBOTSFORD CONCRETE
AQUAPAVE, HERRINGBONE
COLOUR: NATURAL
PERMEABLE PAVER
VISITOR STALLS
ABBOTSFORD CONCRETE
AQUAPAVE, HERRINGBONE
COLOUR: NATURAL
PICNIC TABLES UNDER
METAL AND TIMBER ARBOR
CORNUS KOUSA
X NUTTALLII
'STARLIGHT'
PICEA GLAUCA 'PENDULA'
MAGNOLIA
x 'GALAXY'
SEQUOIADENDRON GIGANTEUM
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
BARKMAN BROADWAY PAVERS; ASH AND CHARCOAL
RAISED CROSSWALK
EXISTING TREES
TO BE RETAINED
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
LIFESPACE RAISED GARDEN PLOTS
CEDARSHED GARDEN SHED
WISHBONE CITYSCAPE BENCH
MUTUAL MATERIALS
VANCOUVER BAY SLAB; CHARCOAL
HAUSER NOVA LOUNGE CHAIR
OPEN LAWN
CARPINUS BETULUS 'FASTIGIATA'
ACER CIRCINATUM KOMPAN CRAWLING PYRAMID
VISITOR BIKE PARKING
ACER RUBRUM 'RED SUNSET'
GROUP SEATING
BARBECUE AREA
WITH MOVEABLE
TABLES AND CHAIRS
NATURE PLAY AREA
WITH FIBAR
SAFETY SURFACE
LARGE BOULDERS
FOR INFORMAL SEATING
KOMPAN
SPINNER PLATE
BALANCE LOGS AND STEPPERS
PICEA OMORIKA
PSEUDOTSUGA MENZIESIISTYRAX JAPONICUS 'PINK CHIMES'
BENCH
BENCH
23
6
S
T
R
E
E
T
METAL FENCE
AND GATE
PERIMETER
FENCE
LANE
+4
9
.
6
0
CORNUS
KOUSA
'SATOMI'
+4
9
.
6
4
+4
9
.
4
9
+4
8
.
8
7
LAWN
LAWN
LAWN
LAWN
LAWN
LAWN
PING PONG
STRUCTURAL
SOIL
UNDER
PAVEMENT
STRUCTURAL
SOIL
UNDER
PAVEMENT
100 20m5 40m
PMG PROJECT NUMBER:22-139
PLANTED SIZE / REMARKSCOMMON NAMEBOTANICAL NAME
PLANT SCHEDULE
KEY QTY
TREE
12 ACER CIRCINATUM VINE MAPLE 1.5M HT; B&B; 3 STEM CLUMP
9 ACER PLATANOIDES 'CRIMSON SENTRY'COLUMNAR CRIMSON SENTRY MAPLE 6CM CAL; B&B
5 CARPINUS BETULUS 'FASTIGIATA'PYRAMIDAL EUROPEAN HORNBEAM 5CM CAL; B&B
18 CORNUS KOUSA X NUTTALLII 'STARLIGHT'STARLIGHT HYBRID DOGWOOD 6CM CAL; 1.5M STD; B&B
13 MAGNOLIA x 'GALAXY'MAGNOLIA 5CM CAL; 1.5M STD
25 PICEA GLAUCA 'PENDULA'WEEPING WHITE SPRUCE 2.5M HT; B&B
10 PICEA OMORIKA SERBIAN SPRUCE 3M HT; B&B
3 PSEUDOTSUGA MENZIESII DOUGLAS FIR 3M HT; B&B
1 SEQUOIADENDRON GIGANTEUM GIANT REDWOOD 5M HT; B&B
21 STYRAX JAPONICUS 'PINK CHIMES'PINK FLOWERED JAPANESE SNOWBELL 5CM CAL; 1.5M STD; B&B
NOTES: * PLANT SIZES IN THIS LIST ARE SPECIFIED ACCORDING TO THE BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD, LATEST EDITION. CONTAINER SIZES
SPECIFIED AS PER CNLA STANDARD. BOTH PLANT SIZE AND CONTAINER SIZE ARE THE MINIMUM ACCEPTABLE SIZES. * REFER TO SPECIFICATIONS FOR DEFINED CONTAINER
MEASUREMENTS AND OTHER PLANT MATERIAL REQUIREMENTS. * SEARCH AND REVIEW: MAKE PLANT MATERIAL AVAILABLE FOR OPTIONAL REVIEW BY LANDSCAPE ARCHITECT AT
SOURCE OF SUPPLY. AREA OF SEARCH TO INCLUDE LOWER MAINLAND AND FRASER VALLEY. * SUBSTITUTIONS: OBTAIN WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT
PRIOR TO MAKING ANY SUBSTITUTIONS TO THE SPECIFIED MATERIAL. UNAPPROVED SUBSTITUTIONS WILL BE REJECTED. ALLOW A MINIMUM OF FIVE DAYS PRIOR TO DELIVERY
FOR REQUEST TO SUBSTITUTE. SUBSTITUTIONS ARE SUBJECT TO BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD - DEFINITION OF CONDITIONS OF
AVAILABILITY. * ALL LANDSCAPE MATERIAL AND WORKMANSHIP MUST MEET OR EXCEED BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD LATEST EDITION. * ALL
PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. * BIO-SOLIDS NOT PERMITTED IN GROWING MEDIUM UNLESS AUTHORIZED BY LANDSCAPE
ARCHITECT.
KOMPAN ROBINIA CRAWLING PYRAMID KOMPAN ROBINIA SPINNER PLATE NATURE PLAY PRECEDENT IMAGE
LIFESPACE RAISED GARDEN PLOTS HAUSER NOVA LOUNGE CHAIR WISHBONE CITYSCAPE BENCH
LIFESPACE HARVEST TABLE WISHBONE LARSON PICNIC TABLE MAGLIN FORO TABLES AND CHARS
BARKMAN BROADWAY PAVERS MUTUAL MATERIALS VANCOUVER BAY SLABS
18 CORNUS KOUSA 'SATOMI'PINK KOUSA DOGWOOD 2.5M HT; B&B
CHK'D:
22139-2.ZIP
DRAWN:
DESIGN:
SCALE:
DATE:
PMG PROJECT NUMBER:22-139
OF 3
DRAWING TITLE:
MAPLE RIDGE
52 UNIT TOWNHOUSE
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO. DATE DR.
23638 DEWDNEY TRUNK ROAD
SEAL:
Copyright reserved. This drawing and design is the
property of PMG Landscape Architects and may not be
reproduced or used for other projects without their
permission.
c
CLIENT:
LANDSCAPE
Burnaby, British Columbia, V5C 6G9
p: 604 294-0011 ; f: 604 294-0022
Suite C100 - 4185 Still Creek Drive
ARCHITECTS
DEVELOPMENT
ALVAIR DEVELOPMENTS LTD
01 22.NOV.15 NEW SITE PLAN; ADD PLANTING MC
LANDSCAPE
PLAN
L1
22.SEP.13
1:250
MC
MC
MCY
100 20m5 40m
PMG PROJECT NUMBER:22-139PMG PROJECT NUMBER: 22-139
PLANTED SIZE / REMARKSCOMMON NAMEBOTANICAL NAME
REPRESENTATIVE PLANT LIST
KEY QTY
SHRUB
ARBUTUS UNEDO COMPACTA COMPACT STRAWBERRY BUSH #7 POT 1.25M
AZALEA JAPONICA 'HINO WHITE'AZALEA; HARDY WHITE #2 POT; 25CM
EUONYMUS ALATA 'COMPACTUS'COMPACT WINGED BURNING BUSH #3 POT; 50CM
HYDRANGEA 'LITTLE LIME'LITTLE LIME HYDRANGEA #2 POT
KALMIA LATIFOLIA 'ELF'DWARF MOUNTAIN LAUREL #3 POT; 50CM
MAHONIA AQUIFOLIUM OREGON GRAPE #3 POT; 50CM
PHOTINIA X FRASERI PHOTINIA #7 POT; 70CM
RHODODENDRON 'ANAH KRUSCHKE'RHODODENDRON; BLUE #3 POT; 50CM
RHODODENDRON 'BLUE DIAMOND'RHODODENDRON; BLUE; APRIL 3 POT; 30CM
SARCOCOCCA HOOKERIANA VAR. HUMILIS HIMALAYAN SWEET BOX #2 POT; 25CM
SPIRAEA JAPONICA 'LITTLE PRINCESS'LITTLE PRINCESS SPIRAEA; PINK #2 POT; 40CM
TAXUS X MEDIA 'HICKSII'HICK'S YEW 1.2M B&B
VACCINIUM CORYMBOSUM 'PINK LEMONADE' BLUEBERRY #3 POT; 80CM
GRASS
HAKONECHLOA MACRA 'ALBOVARIEGATA’ VARIEGATED JAPANESE FOREST GRASS #1 POT
HELICTOTRICHON SEMPERVIRENS BLUE OAT GRASS #1 POT
IMPERATA CYLINDRICA 'RED BARON'BLOOD GRASS #1 POT
PLANTED SIZE / REMARKSCOMMON NAMEBOTANICAL NAME
REPRESENTATIVE PLANT LIST
KEY QTY
PERENNIAL
EPIMEDIUM X RUBRUM RED BARRENWORT 15CM POT
HELLEBORUS x HYBRIDUS LENTEN ROSE 15CM POT
HOSTA 'GOLD STANDARD'HOSTA; YELLOW AND GREEN VARIEGATED #2 POT; 1-2 EYE
LIRIOPE MUSCARI 'BIG BLUE'BIG BLUE LILY-TURF 15CM POT
SEDUM TELEPHIUM 'HERBSTFREUDE'AUTUMN JOY STONECROP 15 CM POT
GC
BLECHNUM SPICANT DEERFERN #1 POT; 20CM
DRYOPTERIS ERYTHROSORA 'BRILLIANCE' BRILLIANCE AUTUMN FERN #1 POT; 25CM
POLYSTICHUM MUNITUM WESTERN SWORD FERN #1 POT; 25CM
NOTES: * PLANT SIZES IN THIS LIST ARE SPECIFIED ACCORDING TO THE BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD, LATEST EDITION. CONTAINER SIZES
SPECIFIED AS PER CNLA STANDARD. BOTH PLANT SIZE AND CONTAINER SIZE ARE THE MINIMUM ACCEPTABLE SIZES. * REFER TO SPECIFICATIONS FOR DEFINED CONTAINER
MEASUREMENTS AND OTHER PLANT MATERIAL REQUIREMENTS. * SEARCH AND REVIEW: MAKE PLANT MATERIAL AVAILABLE FOR OPTIONAL REVIEW BY LANDSCAPE ARCHITECT AT
SOURCE OF SUPPLY. AREA OF SEARCH TO INCLUDE LOWER MAINLAND AND FRASER VALLEY. * SUBSTITUTIONS: OBTAIN WRITTEN APPROVAL FROM THE LANDSCAPE ARCHITECT
PRIOR TO MAKING ANY SUBSTITUTIONS TO THE SPECIFIED MATERIAL. UNAPPROVED SUBSTITUTIONS WILL BE REJECTED. ALLOW A MINIMUM OF FIVE DAYS PRIOR TO DELIVERY
FOR REQUEST TO SUBSTITUTE. SUBSTITUTIONS ARE SUBJECT TO BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD - DEFINITION OF CONDITIONS OF
AVAILABILITY. * ALL LANDSCAPE MATERIAL AND WORKMANSHIP MUST MEET OR EXCEED BC LANDSCAPE STANDARD AND CANADIAN LANDSCAPE STANDARD LATEST EDITION. * ALL
PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. * BIO-SOLIDS NOT PERMITTED IN GROWING MEDIUM UNLESS AUTHORIZED BY LANDSCAPE
ARCHITECT.
HEUCHERA 'FIRE CHIEF'CORAL BELLS; RED 15CM POT
CHK'D:
22139-2.ZIP
DRAWN:
DESIGN:
SCALE:
DATE:
PMG PROJECT NUMBER:22-139
OF 3
DRAWING TITLE:
MAPLE RIDGE
52 UNIT TOWNHOUSE
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO. DATE DR.
23638 DEWDNEY TRUNK ROAD
SEAL:
Copyright reserved. This drawing and design is the
property of PMG Landscape Architects and may not be
reproduced or used for other projects without their
permission.
c
CLIENT:
LANDSCAPE
Burnaby, British Columbia, V5C 6G9
p: 604 294-0011 ; f: 604 294-0022
Suite C100 - 4185 Still Creek Drive
ARCHITECTS
DEVELOPMENT
ALVAIR DEVELOPMENTS LTD
01 22.NOV.15 NEW SITE PLAN; ADD PLANTING MC
PLANTING
PLAN
L2
22.SEP.13
1:250
MC
MC
MCY
2%15
0
m
m
TOWNHOUSE
SIDING
600mm DEPTH 1x4 P.T. FIR/HEM STAKE
75mm DEPTH OF 18.75mm CLEAR CRUSH
2x6 PT. HEADER BOARD ON END
COMPACTED
SUBGRADE
24"X24"X1-5/8" CONCRETE STEPPING PAD
HYDRAPRESSED SLABS
1" SILICA SAND
SETTING BED
4" LIGHT BROOM FINISH CONCRETE
4" COMPACTED TO
95% PROCTOR DENSITY
CRUSH GRAVEL (19MM MINUS)
COMPACTED SUBGRADE
TO 95% SPD
EXPANSION JOINT: 20' O.C.
CONTROL JOINT: 1" DEEP; 5' O.C.
PAVERS
25MM BEDDING SAND
150MM COMPACTED GRANULAR FILL
COMPACTED SUBGRADE
NOTE:
PAVERS TO BE INSTALLED TO MANUFACTURERS
SPECIFICATIONS
1:15
CONCRETE (SIDEWALK AND PAD)1
1:15
CONCRETE STEPPING STONE2
1:15
PAVERS ON GRADE3
1:15
GRAVEL DRAIN STRIP4
8 BARE ROOT/CONTAINER SHRUB PLANTING
N.T.S.
6 PLAY AREA DETAIL
1:25
9 TYPICAL DECIDUOUS TREE DETAIL
1:25
7 PLAY AREA BALANCE LOG
1:25
5'
3'
3X3 POST
POST IN
CONCRETE
FOOTING
3'
NOTE:
ALL METAL PICKETS TO HAVE 2 COATS OF POWDER COATING IN SEMI-GLOSS BLACK
ALL JOINTS TO BE WELDED
3"x2"
4"
2-1/2"x2" RAIL
1:25
3' HT. METAL FENCE AND GATE DETAIL 5
MIN. WIDTH 2X
ROOT BALL WIDTH
15
0
0
10
0
0
DO NOT CUT LEADER
300 mm MIN. OF BACKFILL AROUND ROOT BALL.
USE SOIL FROM PLANTING HOLE IF ACCEPTABLE
BY SOIL TEST RESULTS, OTHERWISE, TOPSOIL TO
BE USED. SOIL TO BE COMPACTED TO 85% STD.
PROCTOR DENSITY TO REMOVE AIR POCKETS.
SCARIFY SIDES AND BOTTOM OF TREE PIT PRIOR
TO PLANTING.
PLANTED HOLE EDGE W/ SHALLOW ANGLE
STAKES DO NOT PENETRATE
OR DAMAGE ROOT BALL.
1.5M Ø x 80MM DEEP WELL FORMED IN TOPSOIL
FOR FIRST YEAR WATERING. BARK MULCH ON AT
A MIN. DIST. OF 150 mm FROM TRUNK. PLANTED HT.
OF ROOT COLLAR RELATIVE TO COVERING SOIL
AT HEIGHT GROWN AT NURSERY; APROX. 50MM
ABOVE EXISTING GRADE.
ALL PLANTING PITS SHALL BE DUG BY HAND AS UNDERGROUND SERVICES MAY
EXIST NEAR STREET TREE LOCATION.
TOPSOIL DEPTH AS PER SPEC. ON SCARIFIED SUBGRADE. FILL WITH SOIL
2/3RDS FULL AND REMOVE STRAPPING, CUT ALL BINDING MATERIAL AND FOLD
BURLAP INTO BOTTOM OF HOLE.
GRADE TO TOPS OF CURBS, WALKS, AND DRIVEWAYS ETC.
50MM WIDE FABRIC BELT /
BANDING IN FIGURE 8
PATTERN ATTACHED TO
STAKE WITH SHINGLE NAILS.
FOR TREES LARGER THAN 65mm CALIPER USE 100
mm Ø P.T. STAKES 2.5 METER IN LENGTH. (ROUND)
TREE STAKES TO BE ALIGNED PARALLEL TO
SIDEWALK/ROAD.
SET TREE PLUMB. USE 2 ROUND STAKES,
EACH SET 1000mm BELOW GRADE & 1500mm
ABOVE GRADE.
TREE BARK SHOULD NOT BE DAMAGED
DURING PLANTING. TREE ROOTS NOT TO
BE EXPOSED TO SUN, FROST OR
DESSICATION.
NOTE: BELT PLACED AT A HEIGHT
NO GREATER THAN 2/3 HEIGHT OF
TREE.
NOTE:
·MULCH TO BE 75mm DEEP AT DRIP LINE. TAPERING TO 0mm AT TRUNK FLARE.
·LOOSEN ROOT MASS PRIOR TO PLANTING.
·CONTAINER IS TO BE CUT CAREFULLY AWAY.
·THE USE OF POLY EDGING AND FILTER FABRIC
300
75
150
SHRUB BED TO
BE MIN 450mm CONTAINER
UNDISTURBED
SOIL
FINISED GRADE
BARE ROOT
MIN. 75mm OF SHREDDED
BARK MULCH
AS PER SPECIFICATION
SPREAD ROOTS EVENLY
OVER COMPACTED MOUND
OF TOPSOIL. PRUNE ALL
DAMAGED ROOTS LEAVING
ROOT TIPS WITH CLEAN
ENDS.
25
0
300
60
0
2%
150MM WIDE CONCRETE CURB
COMPACTED GRANULAR BASE
COMPACTED SUBGRADE
325mm DEPTH FIBAR RESILIENT SURFACE
FILTER FABRIC
100mm DEPTH DRAIN ROCK
100mm DIA. PERFORATED
DRAIN LINE WITH FILTER
FABRIC TIE INTO STORM SYSTEM
2% SLOPE SUBGRADE
TO DRAIN
2 - 25 X 100mm P.T.FIR/HEMLOCK
1"X4" PT FIR/HEMLOCK STAKE
FIBAR
1/
3
O
F
L
O
G
T
O
B
E
B
U
R
I
E
D
BARK TO BE REMOVED FROM LOG
LOGS TO BE 24-36" DIA.
USE DRIFTWOOD IF AVAILABLE
6" LAYER
DRAIN ROCK
3'
2'
9'
-
6
"
16'
16'
10
'
8x8 METAL
SQ. TUBE
FRAME
2X8 METAL LOUVERS
WELDED TO FRAME
I-BEAMS
CONCRETE SUPPORT
COLUMN WITH
CHAMFERED CORNERS
1' O.C.
12
'
ARBOUR - CONCEPT ONLY
(TO BE SIZED BY STRUCTURAL ENGINEER)
- ARBOUR TO BE COLOURED WITH MIN. 2 COATS OF BLACK POWDER COATING
- SUBMIT DESIGN BUILD ENGINEERED SHOP DRAWINGS
I-BEAMS
2X8 METAL LOUVERS
WELDED TO FRAME
10 ARBOR
1:25
CHK'D:
22139-2.ZIP
DRAWN:
DESIGN:
SCALE:
DATE:
PMG PROJECT NUMBER:22-139
OF 3
DRAWING TITLE:
MAPLE RIDGE
52 UNIT TOWNHOUSE
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO. DATE DR.
23638 DEWDNEY TRUNK ROAD
SEAL:
Copyright reserved. This drawing and design is the
property of PMG Landscape Architects and may not be
reproduced or used for other projects without their
permission.
c
CLIENT:
LANDSCAPE
Burnaby, British Columbia, V5C 6G9
p: 604 294-0011 ; f: 604 294-0022
Suite C100 - 4185 Still Creek Drive
ARCHITECTS
DEVELOPMENT
ALVAIR DEVELOPMENTS LTD
01 22.NOV.15 NEW SITE PLAN; ADD PLANTING MC
LANDSCAPE
DETAILS
L3
22.SEP.13
AS SHOWN
MC
MC
MCY
-
APLIN & MARTIN PROJECT No.
DRAWING INDEX
SITE LOCATION PLAN
21-253 / DX 722
MUNICIPAL PROJECT No.5245-20-2022-034
01 COVER SHEET
02 KEY PLAN
03
05
Aplin & Martin Consultants Ltd.
201 - 12448 82 Avenue, Surrey, B.C. Canada V3W 3E9
Tel: (604) 597-9058, Fax: (604) 597-9061, Email: general@aplinmartin.com
PROJECT:
CLIENT:
ALVAIR GROUP PROPERTIES
EMAIL: alvairgroup@gmail.com
PH (778) 839-5018
PROPOSED OFF & ON-SITE WORKS FOR
3 LOTS & 52 TOWNHOUSES
23638 DEWDNEY TRUNK RD &11956, 11946, 11936 & 11926 236 ST
MAPLE RIDGE, B.C.
STORM WATER MANAGEMENT PLAN
COMPREHENSIVE SITE GRADING PLAN
SITE
04 STORM WATER MANAGEMENT VOLUME CALCULATIONS
EGBC Permit to Practice Number #1001018
HC HC
21-253-02
KEY PLAN
ON-SITE & OFF-SITE
0502
DEVELOPER:
PROJECT:
ALVAIR GROUP PROPERTIES
EMAIL:alvairgroup@gmail.com
PH (778) 839-5018
PROPOSED OFF & ON-SITE WORKS FOR
3 LOTS & 52 TOWNHOUSES
23638 DEWDNEY TRUNK ROAD AND 11956, 11946, 11936 & 11926 236 STREET MAPLE RIDGE, BC
Aplin & Martin Consultants Ltd.
201 - 12448 82 Avenue, Surrey, B.C. Canada V3W 3E9
Tel: (604) 597-9058, Fax: (604) 597-9061, Email: general@aplinmartin.com
EGBC Permit to Practice Number #1001018
HC HC
21-253-03
STORM WATER
MANAGEMENT PLAN
0503
DEVELOPER:
PROJECT:
ALVAIR GROUP PROPERTIES
EMAIL:alvairgroup@gmail.com
PH (778) 839-5018
PROPOSED OFF & ON-SITE WORKS FOR
3 LOTS & 52 TOWNHOUSES
23638 DEWDNEY TRUNK ROAD AND 11956, 11946, 11936 & 11926 236 STREET MAPLE RIDGE, BC
Aplin & Martin Consultants Ltd.
201 - 12448 82 Avenue, Surrey, B.C. Canada V3W 3E9
Tel: (604) 597-9058, Fax: (604) 597-9061, Email: general@aplinmartin.com
EGBC Permit to Practice Number #1001018
21-253-04
STORM WATER
MANAGEMENT CALCULATIONS
0504
DEVELOPER:
PROJECT:
ALVAIR GROUP PROPERTIES
EMAIL:alvairgroup@gmail.com
PH (778) 839-5018
PROPOSED OFF & ON-SITE WORKS FOR
3 LOTS & 52 TOWNHOUSES
23638 DEWDNEY TRUNK ROAD AND 11956, 11946, 11936 & 11926 236 STREET MAPLE RIDGE, BC
Aplin & Martin Consultants Ltd.
201 - 12448 82 Avenue, Surrey, B.C. Canada V3W 3E9
Tel: (604) 597-9058, Fax: (604) 597-9061, Email: general@aplinmartin.com
EGBC Permit to Practice Number #1001018
HC HC
21-253-
DEVELOPER:
PROJECT:
05
COMPREHENSIVE SITE
GRADING PLAN
0505
ALVAIR GROUP PROPERTIES
EMAIL: alvairgroup@gmail.com
PH (778) 839-5018
3 LOTS & 52 TOWNHOUSES
23638 DEWDNEY TRUNK ROAD AND 11956, 11946, 11936 & 11926 236 STREET
MAPLE RIDGE, BC
PROPOSED OFF & ON-SITE WORKS FOR
Aplin & Martin Consultants Ltd.
201 - 12448 82 Avenue, Surrey, B.C. Canada V3W 3E9
Tel: (604) 597-9058, Fax: (604) 597-9061, Email: general@aplinmartin.com
EGBC Permit to Practice Number #1001018
Arborist Report
Inventory and Assessment of Trees Associated to Development at
23638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
January 11, 2021
Kimberley Dahl, Diploma for Horticulture,
International Society of Arboriculture Certified Arborist and TRAQ PN 7658A
Hanah Dhanani, Bachelor of Urban Forestry
ISA Certified Arborist PN 9275A
Assignment and Methodology
Woodridge Tree has been retained to undertake an inventory and assessment of trees associated with the development at, 23638 Dewdney Trunk
Rd and 11926, 11936, 11946 and 11956 236 Street,Maple Ridge. The objective is to make tree preservation and protection recommendations in
the context of municipal permits, rules and regulations for development.
Associated trees were visually assessed to determine species, diameter at breast height (dbh) and characteristic description. Tree diameters were
measured at 1.4 meters height with a diameter tape. Protection areas were calculated for all trees within range of the property. Tree hazards were
assessed according to International Society of Arboriculture standards using the TRAQ (Tree Risk Assessment Qualification)method.
Recommendations for removal or retention are based on assessment outcome and proximity of trees to structure and infrastructure. Soil testing,
root exploration and internal probing of tissue have not been incorporated in the findings.
The observations recorded are based on inspections performed on December 6, 2021.
aerial image of property before redevelopment
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 1
Findings
The property at 23638 Dewdney is located on the South side of Dewdney Trunk Rd near the intersection of 136th Street. The properties at 11926,
11936, 11946 and 11956 236 Street are located on the East side of 236 Street near the intersection of Dewdney Trunk Rd. At the time of
observation each lot had a single family house. Associated trees were comprised of native conifers and deciduous species.
23638 Dewdney Trunk Road 11926 236 Street
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 2
11936 236 Street 11946 236 Street
11956 236 Street
image of properties from street at time of field data collection
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 3
Tree Inventory and Assessment
●dbh - Diameter at 1.4m height measured in centimeters
○on trees with multiple stems the 3 largest sections measured at 1.4m are combined to make up the total.
●critical root zone = dbh x 6 unless otherwise specified ●LCR = live crown ratio, percentage of live crown remaining
●ci - City owned tree ●os - off site tree
ID#Common
Name
Botanical
Name
DBH
(cm)
Condition & Comments Action TPZ
(m)
1-702
Cottonwood Populus
trichocarpa
28 Straight, single stem. Natural form. Epicormic growth at base.
Crown radius is 4m. LCR is 75%
Moderate condition
retain 1.68
2-703
Cottonwood Populus
trichocarpa
25 Single stem bends near base and mid stem.
Crown radius is 4m. LCR is 50%.
Moderate condition
retain 1.50
3-704
Weeping
willow
Salix
babylonica
60 Multi stemmed, unbalanced crown to the SouthEast. Natural form. Some
dead in the crown.
Crown radius is 5m. LCR is 75%.
Poor condition
Located in conflict with planned construction.
remove 3.60
4-705
Alder Alnus rubra 40 Dual stem. Epicormic growth at base.
Crown radius is 5m. LCR is 70%.
Good condition
Located in conflict with planned construction.
remove 2.40
5-706
Crab apple Malus spp.60 Multi stemmed. Natural form.
Crown radius is 6m. LCR is 70%.
Good condition
Located in conflict with planned construction.
remove 3.60
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 4
6-707
Douglas Fir Pseudotsuga
menziesii
70 Straight, single stem. Natural form. Pruned for powerline clearance on the
West side.
Crown radius is 5m. LCR is 80%.
Moderate condition
Located in conflict with planned construction.
remove 4.20
7-708
Douglas Fir Pseudotsuga
menziesii
35 Single stem lenas East. Lost top. Low LCR.
Crown radius is 3m. LCR is 15%.
Moderate condition
Located in conflict with planned construction.
remove 2.10
8-709
Western Red
Cedar
Thuja plicata 45 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 90%.
Good condition
Located in conflict with planned construction.
remove 2.70
9-710 Douglas Fir Pseudotsuga
menziesii
35 Topped. Low LCR. Dead lower limbs.
Crown radius is 3m. LCR is 5%.
Poor condition
Located in conflict with planned construction.
remove 2.10
10-711
Western Red
Cedar
Thuja plicata 45 Straight, single stem. Natural form. Located 2m from existing house.
Crown radius is 4m. LCR is 70%.
Good condition
Located in conflict with planned construction.
remove 2.70
11-712
Western Red
Cedar
Thuja plicata 45 Multi stemmed. Poot root flare.
Crown radius is 3m. LCR is 25%.
Moderate condition
Located in conflict with planned construction.
remove 2.70
12-713
Western Red
Cedar
Thuja plicata 45 Multi stemmed, natural form.
Crown radius is 3m. LCR is 25%.
Moderate condition
remove 2.70
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 5
Located in conflict with planned construction.
13-714
Western Red
Cedar
Thuja plicata 45 Multi stemmed, natural form.
Crown radius is 3m. LCR is 25%.
Moderate condition
Located in conflict with planned construction.
remove 2.70
14-715
Douglas Fir Pseudotsuga
menziesii
50 Single stem leans North.
Crown radius is 6m. LCR is 90%.
Good condition
Located in conflict with planned construction.
remove 3.00
15-716
Weeping
willow
Salix
babylonica
40 Single stem, natural form.
Crown radius is 5m. LCR is 50%.
Good condition
Located in conflict with planned construction.
remove 2.40
16-717
Lombardy
Poplar
Populus nigra 40 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 2.40
17-718
Lombardy
Poplar
Populus nigra 45 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 2.70
18-719
Lombardy
Poplar
Populus nigra 50 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 3.00
19-720
Lombardy
Poplar
Populus nigra 25 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 60%.
Good condition
remove 1.50
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 6
Located in conflict with planned construction.
20-721
Lombardy
Poplar
Populus nigra 60 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 3.60
21-722
Spruce Picea spp.45 Dual at 8m. One leader has lost top. Dead lower limbs. Moss throughout
crown.
Crown radius is 5m. LCR is 30%
Moderate condition
Located in conflict with planned construction.
remove 2.70
22-723
Spruce Picea spp.45 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 30%.
Good condition
Located in conflict with planned construction.
remove 2.70
23-724
Spruce Picea spp.40 Straight, single stem. Natural form.
Crown radius is 4m. LCR is 50%.
Good condition
Located in conflict with planned construction.
remove 2.40
24-725
Cherry Prunus spp.30 Dual stem at 1m. Leans NorthWest.
Crown radius is 5m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 1.80
25-726
Lombardy
Poplar
Populus nigra 20 Straight, single stem. Natural form.
Crown radius is 2m. LCR is 50%.
Good condition
remove 1.20
26-727 Lombardy Populus nigra 40 Straight, single stem. Natural form.remove 2.40
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 7
Poplar Crown radius is 4m. LCR is 60%.
Good condition
Located in conflict with planned construction.
27-728
Lombardy
Poplar
Populus nigra 80 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 90%.
Good condition
remove 4.80
28-729
Western Red
Cedar
Thuja plicata 35 Part of a row of trees that share a crown. Straight, single stem. Natural
form.
Crown radius is 5m. LCR is 100%.
Good condition
Located in conflict with planned construction.
remove 2.10
29-730
Western Red
Cedar
Thuja plicata 20 Part of a row of trees that share a crown. Straight, single stem. Natural
form.
Crown radius is 5m. LCR is 100%.
Good condition
Located in conflict with planned construction.
remove 1.20
30-731
Western Red
Cedar
Thuja plicata 35 Part of a row of trees that share a crown. Straight, single stem. Natural
form.
Crown radius is 5m. LCR is 100%.
Good condition
Located in conflict with planned construction.
remove 2.10
31-732
Western Red
Cedar
Thuja plicata 40 Part of a row of trees that share a crown. Straight, single stem. Natural
form.
Crown radius is 5m. LCR is 100%.
Good condition
Located in conflict with planned construction.
remove 2.40
32-733
Horse
Chestnut
Aesculus
hippocastanum
30 Dual stems lean West. Natural form.
Crown radius is 5m. LCR is 80%.
remove 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 8
Good condition
Located in conflict with planned construction.
33-734
Spruce Picea spp.40 Dual stems. Natural form.
Crown radius is 4m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 2.40
34-735
Spruce Picea spp.30 Straight, single stem. Natural form.
Crown radius is 4m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 1.80
35-736
Spruce Picea spp.50 Multi stemmed, natural form.
Crown radius is 3m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 3.00
36-737
Western Red
Cedar
Thuja plicata 50 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 70%.
Good condition
Located in conflict with planned construction.
remove 3.00
37-738
Western Red
Cedar
Thuja plicata 50 Straight, single stem. Natural form. Tree 739 growing up through the
crown.
Crown radius is 5m. LCR is 70%.
Good condition
Located in conflict with planned construction.
remove 3.00
38-739
Mountain Ash Sorbus
aucuparia
24 Dual stem. Growing up into the crown of tree 738.
Crown radius is 1m. LCR is 40%.
Moderate condition
Located in conflict with planned construction.
remove 1.44
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 9
39-740
Plum Prunus spp.50 Multi stemmed, sweeps South at base.
Crown radius is 5m. LCR is 60%.
Good condition
Located in conflict with planned construction.
remove 3.00
40-741
Spruce Picea spp.30 Topped with regenerated leaders. Mechanical damage to exposed roots.
Under power lines.
Crown radius is 3m. LCR is 60%.
Moderate condition
Located in conflict with planned construction.
remove 1.80
41-742
Spruce Picea spp.20 Topped with a regenerated leader. Large cavity of decay at topping point.
Under power lines.
Crown radius is 1m. LCR is 15%.
Poor condition
remove 1.20
42-743
Spruce Picea spp.50 Dual stem topped with regenerated leaders. Under power lines.
Crown radius is 5m. LCR is 50%.
Moderate condition
remove 3.00
43-744
Spruce Picea spp.60 Dual stem topped with regenerated leaders. Under power lines.
Heavy resinosis on the trunk.
Crown radius is 5m. LCR is 50%.
Moderate condition
remove 3.60
44-745
Mountain Ash Sorbus
aucuparia
50 Multi stemmed. Unbalanced crown. Large wound on main stem in hollow
and decayed.
Crown radius is 4m. LCR is 50%.
Poor condition
remove 3.00
45-746
Cherry Prunus spp.25 Multi stemmed, natural form.
Crown radius is 5m. LCR is 60%.
Good condition
Located in conflict with planned construction.
Remove 1.50
46-747
Cherry Prunus spp.40 Dual stem, topped with epicormic regrowth.
Crown radius is 5m. LCR is 50%.
Moderate condition
remove 2.40
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 10
Located in conflict with planned construction.
47-748
Weeping
willow
Salix
babylonica
20 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 50%.
Good condition
Located in conflict with planned construction.
remove 1.20
48-749
Crab apple Malus spp.30 Multi stemmed. Natural form. Some dead in crown.
Crown radius is 5m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 1.80
49-750
Horse
Chestnut
Aesculus
hippocastanum
20 Single stem leans East. Natural form.
Crown radius is 5m. LCR is 60%.
Good condition
retain 1.20
50-751
Spruce Picea spp.30 Mostly dead, sparse foliage, dead top.
Crown radius is 4m. LCR is 15%.
Poor condition
remove 1.80
51-752
Douglas Fir Pseudotsuga
menziesii
60 Dual stem at base. Natural form.
Crown radius is 4m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 3.60
52-753
Douglas Fir Pseudotsuga
menziesii
60 Straight, single stem. Natural form.
Crown radius is 4m. LCR is 60%.
Moderate condition
Located in conflict with planned construction.
remove 3.60
53-757
Mountain Ash Sorbus
aucuparia
30 Multi stemmed, natural form. On slope.
Crown radius is 5m. LCR is 50%.
Good condition
retain 1.80
54-758
Smaragd
Cedar
Thuja
occidentalis
20 Single stem leans West. Natural form. Unbalanced crown.
Crown radius is 1m. LCR is 80%.
Moderate condition
retain 1.20
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 11
55-759
Mountain Ash Sorbus
aucuparia
30 Dual stem at base. Wounds, decay and moss throughout the crown.
Crown radius is 4m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 1.80
56-760
Plum Prunus spp.40 Multi stemmed. Decay observed on leaders.
Crown radius is 5m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 2.40
57-761
Lombardy
Poplar
Populus nigra 50 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 90%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
58-762
Pine Pinus spp.30 Straight, single stem. Natural form. Dead lower limbs
Crown radius is 3m. LCR is 40%.
Moderate condition
Located in conflict with planned construction.
remove 1.80
59-763
Western Red
Cedar
Thuja plicata 70 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 40%.
Moderate condition
Located in conflict with planned construction.
remove 4.20
60-764
Alder Alnus rubra 45 Single stem with self corrected lean West.
Crown radius is 5m. LCR is 50%.
Moderate condition
It’s location conflicts with proposed sidewalk.
remove 2.70
61-765
Cottonwood Populus
trichocarpa
100 Dual stems lean West. Mature tree.
Crown radius is 5m. LCR is 90%.
Good condition
Located in conflict with planned construction.
remove 6.00
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 12
62-766
Cottonwood Populus
trichocarpa
50 Straight, single stem. Natural form.
Crown radius is 3m. LCR is 40%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
63-767
Cottonwood Populus
trichocarpa
45 Straight, single stem. Natural form.
Crown radius is 4m. LCR is 90%.
Moderate condition
Located in conflict with planned construction.
remove 2.70
64-768
Cottonwood Populus
trichocarpa
40 Single stem leans North. Natural form.
Crown radius is 3m. LCR is 60%.
Moderate condition
Located in conflict with planned construction.
remove 2.40
65-769
Apple Malus spp.30 Dual stem with severe lean NorthWest.
Crown radius is 5m. LCR is 60%.
Poor condition
remove 1.80
66-770
Cottonwood Populus
trichocarpa
45 Straight, single stem. Natural form.
Crown radius is 5m. LCR is 60%.
Moderate condition
Located in conflict with planned construction.
remove 2.70
67-771
Alder Alnus rubra 50 Single stem leans NorthWest. Overwhelmed with ivy.
Crown radius is 5m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
68-772
Alder Alnus rubra 25 Straight, single stem. Overwhelmed with ivy.
Crown radius is 3m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 1.50
69-773 Alder Alnus rubra 30 Single stem leans North. Overwhelmed with ivy.remove 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 13
Crown radius is 3m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
70-774
Douglas Fir Pseudotsuga
menziesii
90 Straight, single stem. Natural form. Overwhelmed with ivy.
Crown radius is 6m. LCR is 60%.
Moderate condition
Located in conflict with planned construction.
remove 5.40
71-775
Alder Alnus rubra 35 Straight, single stem. Natural form. Overwhelmed with ivy.
Crown radius is 4m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 2.10
72-776
Crab apple Malus spp.60 Multi stemmed. Unbalanced crown. Overwhelmed with ivy.
Crown radius is 7m. LCR is 50%.
Poor condition
remove 3.60
73-777
Cottonwood Populus
trichocarpa
60 Straight, single stem. Natural form. Overwhelmed with ivy.
Crown radius is 4m. LCR is 30%.
Moderate condition
Located in conflict with planned construction.
remove 3.60
74-778
Cottonwood Populus
trichocarpa
60 Straight, single stem. Natural form. Overwhelmed with ivy.
Crown radius is 4m. LCR is 30%.
Moderate condition
Located in conflict with planned construction.
remove 3.60
75-779
Cottonwood Populus
trichocarpa
50 Straight, single stem. Lost top. Ivy up base.
Crown radius is 4m. LCR is 30%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
76-780 Cottonwood Populus 50 Straight, single stem. Lost top. Ivy up base.remove 3.00
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 14
trichocarpa Crown radius is 4m. LCR is 30%.
Moderate condition
Located in conflict with planned construction.
77-781
Cottonwood Populus
trichocarpa
50 Single stem leans SouthEast. Ivy up base.
Crown radius is 4m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
78-782
Crab apple Malus spp 45 Multi stemmed. Overwhelmed with ivy.
Crown radius is 4m. LCRis 50%.
Moderate condition
Located in conflict with planned construction.
remove 2.70
79-783
Douglas Fir Pseudotsuga
menziesii
95 Mature. Straight, single stem. Ivy up base.
Crown radius is 8m. LCR is 80%.
Moderate condition
Located in conflict with planned construction.
remove 5.70
80-784
Douglas Fir Pseudotsuga
menziesii
80 Mature. Straight, single stem. Ivy up base.
Crown radius is 8m. LCR is 80%.
Moderate condition
Located in conflict with planned construction.
remove 4.80
81-785
Cottonwood Populus
trichocarpa
35 Single stem overwhelmed with ivy.
Crown radius is 3m. LCR is 25%.
Moderate condition
remove 2.10
82-786
Douglas Fir Pseudotsuga
menziesii
40 Single stem with self corrected lean North. Ivy up base.
Crown radius is 4m. LCR is 25%.
Moderate condition
Located in conflict with planned construction.
remove 2.40
83-787
Douglas Fir Pseudotsuga
menziesii
40 Straight, single stem. Natural form. Ivy up base.
Crown radius is 4m. LCR is 30%.
remove 2.40
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 15
Moderate condition
Located in conflict with planned construction.
84-788
Douglas Fir Pseudotsuga
menziesii
25 Straight, single stem. Natural form. Ivy up base.
Crown radius is 4m. LCR is 25%.
Moderate condition
Located in conflict with planned construction.
remove 1.50
85-789
Cottonwood Populus
trichocarpa
50 Straight, single stem. Natural form. Ivy up base.
Crown radius is 5m. LCR is 50%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
86-790
Cottonwood Populus
trichocarpa
50 Straight, single stem. Natural form. Ivy up base.
Crown radius is 4m. LCR is 30%.
Moderate condition
Located in conflict with planned construction.
remove 3.00
ci1 Hawthorn Crataegus
laevigata
27 Natural form. Power lines run through the crown.
Crown radius is 4m. LCR is 60%
Good condition
retain 1.62
ci2 Hawthorn Crataegus
laevigata
24 Natural form. Power lines run through the crown.
Crown radius is 4m. LCR is 60%
Good condition
retain 1.44
ci3 Hawthorn Crataegus
laevigata
7 Straight, single stem. Immature. Natural form.
Crown radius is 1m. LCR is 60%.
Good condition
retain 0.42
ci4 Horse
Chestnut
Aesculus
hippocastanum
110 Multi stemmed. Topped
Crown radius is 6m. LCR is 50%.
Moderate condition
retain 6.60
ci5 Douglas Fir Pseudotsuga
menziesii
70 Topped, cut in half. Mature tree.
Crown radius is 3m. LCR is 60%.
Moderate condition
retain 4.20
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 16
ci6 Western Red
Cedar
Thuja plicata 45 Single stem, topped.
Crown radius is 6m. LCR is 100%.
Moderate condition
retain 2.70
os1 Douglas Fir Pseudotsuga
menziesii
60 Part of a row of trees. Single stem kinked mid trunk. Natural form.
Crown radius is 4m. LCR is 75%.
Good condition
Tree is located on a shared property line
Retain
Arboirst to supervise
excavation.
3.60
os2 Spruce Picea spp.60 Part of a row of trees. Straight, single stem. Natural form.
Crown radius is 4m. LCR is 75%.
Good condition
Retain
Arboirst to supervise
excavation.
3.60
os3 Spruce Picea spp.50 Part of a row of trees. Straight, single stem. Topped.
Crown radius is 5m. LCR is 80%.
Moderate condition
Retain
Arboirst to supervise
excavation.
3.00
os4 Spruce Picea spp.40 Part of a row of trees. Straight, single stem. Natural form.
Crown radius is 4m. LCR is 75%.
Good condition
Retain
Arboirst to supervise
excavation.
2.40
os5 Cottonwood Populus
trichocarpa
25 Straight, single stem. Immature. Natural form.
Crown radius is 3m. LCR is 75%.
Good condition
retain 1.50
os6 Cherry Prunus spp.35 Straight, single stem. Natural form.
Crown radius is 4m. LCR is 60%.
Good condition
retain 2.10
os7 Cherry Prunus spp.50 Dual stem. Natural form.
Crown radius is 4m. LCR is 60%.
Good condition
retain 3.00
os8 Alder Alnus rubra 70 Mature tree. Wounds at base. Base of slope.
Crown radius is 5m. LCR is 60%.
Moderate condition
Retain 4.20
os9 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
retain 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 17
Moderate condition
os10 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os11 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os12 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os13 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os14 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os15 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os16 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os17 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os18 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os19 Douglas Fir Pseudotsuga 30 Part of a row of trees. Located on top of a slope. Single stem. Natural retain 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 18
menziesii form.
Crown radius is 4m. LCR is 80%.
Moderate condition
os20 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os21 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os22 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os23 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os24 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os25 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os26 Douglas Fir Pseudotsuga
menziesii
65 Part of a row of trees. Located on a slope. Single stem sweeps West at
base. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 3.90
os27 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os28 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 19
os29 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
os30 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located at the bottom of a slope. Single stem.
Natural form. Sloughing bark at base. Damage to exposed roots and root
flare.
Crown radius is 4m. LCR is 80%.
Poor condition
retain 1.80
os31 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os32 Western Red
Cedar
Thuja plicata 25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os33 Douglas Fir Pseudotsuga
menziesii
25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os34 Western Red
Cedar
Thuja plicata 25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os35 Western Red
Cedar
Thuja plicata 25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Retain
Arborist to supervise
1.50
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 20
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
excavation for the
sidewalk preparation.
os36 Western Red
Cedar
Thuja plicata 35 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
2.10
os37 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os38 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os39 Western Red
Cedar
Thuja plicata 25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os40 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os41 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Retain
Arborist to supervise
1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 21
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
excavation for the
sidewalk preparation.
os42 Douglas Fir Pseudotsuga
menziesii
25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os43 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os44 Douglas Fir Pseudotsuga
menziesii
25 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os45 Douglas Fir Pseudotsuga
menziesii
25 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.50
os46 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os47 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Retain
Arborist to supervise
1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 22
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
excavation for the
sidewalk preparation.
os48 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os49 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os50 Douglas Fir Pseudotsuga
menziesii
40 Part of a row of trees. Located on top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
2.40
os51 Douglas Fir Pseudotsuga
menziesii
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
It’s location conflicts with proposed sidewalk.
Remove
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os52 Cottonwood Populus
trichocarpa
30 Part of a row of trees. Located on a slope. Single stem. Natural form.
Crown radius is 4m. LCR is 80%.
Moderate condition
It’s location conflicts with proposed sidewalk.
Remove
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os53 Alder Alnus rubra 70 Multi stemmed, natural form.
Crown radius is 5m. LCR is 60%.
Moderate condition
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
4.20
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 23
Proposed sidewalk is in close proximity to the TPZ
os54 Cottonwood Populus
trichocarpa
65 Single stem. Natural form. Ivy up base.
Crown radius is 4m. LCR is 80%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
3.90
os55 Cottonwood Populus
trichocarpa
40 Single stem. Natural form. Ivy up base.
Crown radius is 3m. LCR is 60%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
2.40
os56 Douglas Fir Pseudotsuga
menziesii
30 Single stem. Natural form. Ivy up base.
Crown radius is 3m. LCR is 40%.
Moderate condition
Proposed sidewalk is in close proximity to the TPZ
Retain
Arborist to supervise
excavation for the
sidewalk preparation.
1.80
os57 Western Red
Cedar
Thuja plicata 30 Part of a row of trees. Locate on the top of a slope. Single stem. Natural
form.
Crown radius is 4m. LCR is 80%.
Moderate condition
retain 1.80
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 24
Images
Image 1- Off site trees along East property line Image 2- Off site trees along East property line
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 25
Image 3- Tree ci2 Image 4- Tree ci4
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 26
Image 5- Trees in the backyards off properties off of 236 Street Image 6- Trees in the backyards off properties off of 236 Street
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 27
Conclusion
Property, plans and trees have been assessed by arborists to determine tree management recommendations for construction. Those
recommendations follow:
Summary Table
subject property off-site City property
# of trees in total 86 57 6
# to be removed 81 2 0
# to be protected 5 55 6
Recommended Tree Removals:
●The proposed plans require removal of 81 trees onsite plus 2 which are located on a neighboring property.
Recommended Tree Protection:(Pending coordination with site plans)
●Tree barriers shown on the “Tree Plan for Construction”are to be installed and kept in place during the entire duration of construction.
●Arborist supervision is required for the installation of the sidewalk in proximity to trees os31 through to os56.
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 28
Limitations and Assumptions
●This report was prepared for and on behalf of the client and it is intended solely for their use. Woodridge Tree Consulting Arborists Ltd. shall
not accept any liability derived from the partial, unintended, unauthorized or improper use of this report.
●This report is restricted to the subject trees as detailed in the report. No other trees were inspected or assessed as part of the work related
to the preparation of this report.
●The accuracy and ownership of the locations of trees, property lines and other site features were not verified by Woodridge Tree. Third
party information to the consultant may have been relied upon in the formation of the opinion of the consultant in the preparation of this
report, and that information is assumed to be true and correct.
●The use of maps, sketches, photographs and diagrams are intended only as a reference for the reader's use in understanding the contents
and findings of this report, and are not intended as a representation of fact.
●Approvals from a municipal or senior government agency may be required in relation to certain recommendations and treatments provided
in this report. The owner is responsible to make an application for, pay related fees and meet all requirements and conditions for the
issuance of such permits, approvals or authorizations.
I certify to the best of my knowledge or belief that:
●staff from this firm have performed site inspections on the dates as stated herein
●the findings are based on information known to the consultant at that time
●the statements of fact determined by the consultant are true and correct
If there are questions regarding the contents of this report please contact our office.
Kimberley Dahl
ISA Certified Arborist and Tree Risk Assessor
PN 7658A
Diploma in Horticulture
Woodridge Tree Consulting Arborists Ltd.
kimberley@woodridgetree.com
Hanah Dhanani
ISA Certified Arborist
PN 9275A
Bachelor of Urban Forestry
Woodridge Tree Consulting Arborists Ltd.
hanah@woodridgetree.com
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 29
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 30
Arborist Report for 223638 Dewdney Trunk Rd and 11926, 11936, 11946 and 11956 236 Street, Maple Ridge
Woodridge Tree Consulting Arborists Ltd.
Page 31
Page 1111 of 4444
City of Maple RidgeCity of Maple RidgeCity of Maple RidgeCity of Maple Ridge
TO:TO:TO:TO: Advisory Design Panel MEETING DATE:MEETING DATE:MEETING DATE:MEETING DATE: May 17, 2023
FILE NO:FILE NO:FILE NO:FILE NO: 2021'579'DP
SUBJECT:SUBJECT:SUBJECT:SUBJECT: 23682 Dewdney Trunk Road
PURPOSE:PURPOSE:PURPOSE:PURPOSE:
An Advisory Design Panel (the “ADP”) submission has been received for the above cited application and
property to permit the construction of 16 townhouse units with 2195 square metres and two single family.
The rezoning application being processed in conjunction with this proposal was given First Reading by
Council on March 1, 2022.
A portion of the subject site is being re'zoned to RM'1 (Low Density Townhouse Residential) to
accommodate the proposal. The development permit application made to the City is subject to Section
8.7 Multi'Family.
BACKGROUND:BACKGROUND:BACKGROUND:BACKGROUND:
Applicant: GEOFF LAWLOR ARCHITECT AIBC
Owner: 1041129 B C LTD
Legal Description: Lot: 7, Section: 16, Township: 12, Plan: NWP1676
OCP:
Existing: RES (Urban Residential)
Proposed: RES (Urban Residential)
Zoning:
Existing: M'1 (Service Industrial)
Proposed: RM'1 (Low Density Townhouse Residential)
Surrounding Uses:
North: Use: Single'Family Residential
Zone: R'3 (Single Detached (Intensive) Urban Residential)
Designation: Urban Residential
South: Use: Single'Family Residential
Zone: RS'1b (Single Detached (Medium Density)
Residential)
Designation: Urban Residential
East: Use: Single'Family Residential
Zone: RS'1b (Single Detached (Medium Density) Residential) &
CD'1'93 (Amenity Residential District)
Designation: Urban Residential
West: Use: Industrial
Page 2222 of 4444
Zone: M'2 (General Industrial)
Designation: Urban Residential
Existing Use of Property: Vacant
Proposed Use of Property: Single'Family and Multi'Family residential
Site Area: 0.46 ha (1.1 acres)
Access: 119 Avenue and new lane off of 237 Street
Servicing requirement: Urban Standard
DEVELOPMENT PERMIT AREA:DEVELOPMENT PERMIT AREA:DEVELOPMENT PERMIT AREA:DEVELOPMENT PERMIT AREA:
The development permit application made to the City prompting this submission to the ADP is subject
to the Key Guidelines and the Design Guidelines of Section 8.7 Multi'Family Development Permit.
Key Guidelines:
The following is a brief description and assessment of the proposal’s compliance with the applicable
Key Development Permit Guidelines:
A Multi'Family Development permit is required for all new multi'family development. The purpose of a
Multi'Family Development Permit is to enhance existing neighborhoods with compatible housing styles
that meet diverse needs and minimize potential conflicts on neighboring land uses. The Key Guideline
Concepts are as follows:
1. New development into established areas should respect private spaces, and incorporate local
neighborhood elements in building form, height, architectural features and massing.
2. Transitional development should be used to bridge areas of low and high densities, through
means such as stepped building heights, or low'rise ground'oriented housing located to the
periphery of a higher density developments.
3. Large scale developments should be clustered and given architectural separation to foster a
sense of community, and improve visual attractiveness.
4. Pedestrian circulation should be encouraged with attractive streetscapes attained through
landscaping, architectural details, appropriate lighting, and by directing parking underground
where possible or away from public view through screened parking structures or surface
parking located to the rear of the property.
Design Guidelines:
The Design Guidelines and a full explanation of how the project complies with them or the reasons
why they are not applicable are attached in Appendix F to this memo.
Page 3333 of 4444
PLANNING COMMENTS:PLANNING COMMENTS:PLANNING COMMENTS:PLANNING COMMENTS:
1. Proposal:
The current application is proposing to rezone the subject property from M'1 (Service Industrial)
to RM'1 (Low Density Townhouse Residential) and R'2 (Single Detached (Medium Density) Urban
Residential) to permit the future construction of approximately 16 townhouse units fronting onto
119 Avenue and 2 single'family lots fronting on to Dewdney Trunk Road. This will included
construction of a lane that will provide access to both the townhouse site and single family lots.
This site has been vacant and underutilized under the current zoning of M'2 (General Industrial)
due to the narrow lot width and has a number of trees currently on the property.
2. OCP and Zoning Compliance:
The subject site is designated Urban Residential and the proposed zoning complies with this
designation.
The subject site is currently zoned M'2 (General Industrial) and Development Data Sheet
(Appendix E) analyses the compliance of the project with the applicable zone regulations. The
proposal has a density (Floor Space Ratio) of 0.6 which complies with the maximum density of
0.6 as per the Zoning Bylaw.
The following variances will be required:
• To vary the required lot width for the RM'1 Zone from 27 metres to 24.68 metres.
3. Parking and bicycle storage:
The required parking for the proposed use is analyzed in the Development Data Sheet (Appendix
E).
The Off Street Parking and Loading Bylaw No. 4350 – 1990 requires that the RM'1 (Townhouse
Residential) zone provide two off'street parking spaces per dwelling unit, plus 0.2 spaces per
dwelling unit designated for visitors. All parking has been provided in concealed, side'by'side
garages and there 5 proposed visitor parking spots.
4. Environmental, Sustainability & Stormwater Management:
The application will be assessed under the 3 tier stormwater rainwater management
requirements with emphasis on Tier A opportunities for infiltration, bio'filtration and exfiltration
along with water quality controls.
5. Issues requiring comments from ADP:
Please comment on the overall form and character of this development and identify and issues
that the applicant should be aware of.
6. Garbage/Recycling:
Garbage and recycling can be stored in the garage of each unit and will be collected via the
internal strata road.
Page 4444 of 4444
7. Works along abutting roads:
Curb and gutter are a required along 119 Avenue and along the new lane. The existing curb and
gutter along Dewdney Trunk Road is to be evaluated by the applicant’s civil engineer to determine
if it is sufficient. A sidewalk will not be required along 119 Avenue as it already exists on the south
side of the street. Additionally, 119 Avenue is to be constructed to a collector road standard
across the proposed multi'family land use.
Decorative LED street light design along Dewdney Trunk Road is required, however, street lights
are not required along 119 Avenue as they exist on the south side of the street. Additionally, a
street tree design for 119 Avenue and Dewdney Trunk Road will be required.
8. Off Site Upgrades, Utilities and Services:
The site is serviced by an existing sanitary sewer and watermain along 119 Avenue and this will
serve the proposed townhouse site. The services for the single family lots will be required to be
extended along the lane to the west. A preliminary storm water management plan (SMP) has been
submitted and has proposed a number of strategies on'site to retain and infiltrate water that
appear to meet the City’s design criteria. The applicant is required to service the site using
underground utilities.
CONCLUSION:CONCLUSION:CONCLUSION:CONCLUSION:
The Planning Department requests that the Advisory Design Panel provide comments on the development
proposal.
______________________________________________
Prepared by: April Crockett
The following appendices are attached hereto:
Appendix A Subject map
Appendix B Explanatory letter from Architect (and Landscape Architect if applicable)
Appendix C ADP Submission Form
Appendix D ADP Applicant Checklist (signed by Architect)
Appendix E Development Data Sheet (signed by Architect)
Appendix F DP Area Guidelines Checklist
Appendix G Architectural and Landscaping Plans
DATE: Feb 8, 2022FILE: 2021-579-RZ
23682 DEWDNEY TRUNK ROADPID: 012-293-148
PLANNING DEPARTMENT
236 ST
119 AVE
237A ST
237 ST
DEWDNEY TRUNK RD
120A LANE
LANE N OF DTR
236B ST
118A AVE
119B AVE
LANE S OF DTR
237 ST
237 ST
LANE S OF DTR
´
Scale: 1:2,000 BY: AC
Legend
Parcels selection
Stream
Indefinite Creek
SUBJECT PROPERTY
Wednesday, April 19, 2023
City of Maple Ridge
11995 Haney Place
Maple Ridge, BC
V2X 6A9
Attn.: Manager of Development and Environmental Services
Re: ADP Covering Letter
2021-579-RZ, 23682 Dewdney Trunk Road, Maple Ridge
Dear Sir,
The above project proposes the rezoning and subdivision of a vacant site from the existing M-1 to RM-1
for a townhouse project and 2 R-2 lots for single family.
The existing M-1 lot has remained undeveloped for many years due to its long and narrow dimensions
which make industrial use very uneconomic. The proposed zonings align with the OCP in providing
denser housing.
The proposed design respects the general appearance of the immediate vicinity but with up-graded
higher quality materials: fibre cement siding and cultured stone, all with appropriate massing.
Site grades provide for rainwater dispersal via a nominal slope across 350mm deep topsoil from the rear
of the buildings to the east property line where it is collected in a bioswale and directed to an in-ground
infiltration/detention system. Rainwater leaders are also directed to this same system where possible.
Rainwater falling directly on the road are directed to the onsite underground stormwater detention pipe
and oil interceptor. The requirements of the City’s Tier A, B & C storm water policy are met by the
infiltration/detention system.
Sustainable construction strategies include the following:
i) LED lighting throughout
ii) EV charging stations for each unit
iii) Heat recovery systems which incorporate heat pumps
iv) Locally sourced construction materials
v) Rainwater absorption in accordance with City directive
Respectfully submitted,
Geoff Lawlor Architect AIBC
Principal, Geoff Lawlor Architect AIBC
The City
schedule
making y
ADP subm
ADP thro
Applicati
Name of
File num
Address
Current Z
Seeking t
Architect
Submissi
Architect
Landscap
Other Pro
Note.: Th
developm
taken fro
bulletin,
Major
per th
build
Group A (Pa
Group B (Pa
Group C Res
Group D & E
Group F (F1
Adv
of Maple Rid
es for submis
your submiss
mission pack
ough your Fil
ion Informa
Applicant
ber
of site
Zone
to appear be
t Informatio
on will be p
t
pe Architect
ofessional (S
he Architects
ments to the
om AIBC Bull
click here.
Occupancy
he current
ing codes
art 3)
art 3)
sidential
E
: Part 3)
isory Des
dge Advisory
ssion deadlin
sion, contact
kage for you
le Manager w
tion:
_________
_________
_________
_________
efore the AD
on:
resented to
_________
_________
State Name
s are require
e ADP that a
letin 31 Build
Public Assem
Hospital, San
Home for the
Aged
Institutional
Hotel or sim
Commercial
Industrial
sign Pane
y Design Pan
ne dates and
t your File M
ur project. Fo
well in adva
__________
__________
__________
___ Propose
DP on this da
ADP by:
__________
__________
& Role) ____
ed to prepar
re in the Ma
dings Requir
Use
mbly
natorium, or
e
ilar occupancy
el Submis
nel (ADP) me
d for the min
Manager to e
orward your
nce of the d
___________
_____
___________
ed Zone ____
ate ________
___________
___________
__________
re plans and
ajor Occupan
ring the Serv
Type
services
− any o
exce
− any b
exce
− all sc
− any b
capa
− any b
− any b
− any b
− any b
− any b
ssion Req
eets monthly
nimum subm
establish wh
r complete s
deadline date
__________
__________
__________
__________
________
_______
___________
to attend a
ncy categori
vices of an A
es of Building or
s of an architect
one‐storey build
eeding 9 m or gro
building of more
eeding 235 m²; a
chools, any size
building (exclud
acity exceeding 1
building with gro
building contain
building contain
building with gro
building with gro
uest Form
y.Refer to t
mission requ
at constitute
ubmission p
e.
__
__
__
__
__________
nd to presen
es cited in th
Architect. Fo
r Parts of Buildin
t under section 6
Act.
ding with an uns
oss area exceed
e than one store
and
ing veterinary h
12 beds
oss area exceed
ning 5 or more d
ning 11 or more g
oss area exceed
oss area exceed
m
he attached
irements. Be
es a complet
package for t
____
nt all
he Table bel
r the entire
ng requiring the
60 of the Archit
supported span
ing 275 m²;
ey with gross are
ospital) with a
ing 470 m²
welling units
guest rooms
ing 470 m²
ing 470 m²
efore
te
the
ow
e
ects
ea
1
Multi-Family Development Permit Area Guidelines Checklist
Pursuant with Section 8.7 of the Official Community Plan, multi-family developments will be
assessed against the form and character guidelines established by Council and summarised
below.
This checklist is to be prepared by the architect of record for the project to demonstrate the
proposed design was developed in accordance with the form and character guidelines. Please
assess and describe the compliance of the proposed design of the project with respect to the
Key Guideline Concepts and with the Form and Character Guidelines.
Description of the Key Guideline Concepts should be suitable for File Managers to quote in
Development Permit Application Reports to Council. For the Form and Character Guidelines,
clearly describe how the proposed design complies with each of the listed guidelines, or
describes why a guideline is not complied with or why it is inapplicable.
This checklist is to accompany Development Permit Applications and submissions to the ADP.
8.7.1 Key Guideline Concepts Describe how this project and the design complies
1. New development into established areas
should respect private spaces, and
incorporate local neighbourhood
elements in building form, height,
architectural features and massing.
2. Transitional development should be used
to bridge areas of low and high densities,
through means such as stepped building
heights, or low rise ground oriented
housing located to the periphery of a
higher density developments.
2
Key Guideline Concepts (Continued)
3. Large scale developments should be
clustered and given architectural
separation to foster a sense of
community, and improve visual
attractiveness.
4. Pedestrian circulation should be
encouraged with attractive streetscapes
attained through landscaping,
architectural details, appropriate lighting
and by directing parking underground
where possible or away from public view
through screened parking structures or
surface parking located to the rear of the
property.
Guidelines 8.7.1 A
Building Design, Massing and Siting
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Design and siting of buildings should take
advantage of natural features or views
and should enhance privacy and
livability.
2. Residential buildings should front or
appear to front onto public roads
through the use of appropriate
treatment of exteriors, through direct
pedestrian access to individual units from
the public street/sidewalk, or through
the provision of pedestrian walkways
linked to the street. Street frontages
should be emphasized by incorporating
differentiated front, side and rear
oriented facades, with a minimum two
storey facade on the fronting street to
foster a human scale. Buildings that are
designed with an end wall or unit
adjacent to a public street should design
the end unit with the pedestrian entry
facing the street. At significant
intersections, the definition of corners
should be reinforced by buildings that
front on both streets and incorporate
corner cuts.
3
Guidelines 8.7.1 A (Continued)
3. Higher density dwellings should be sited
adjacent to major streets in order to
minimize access problems and to provide
a transition to lower density uses.
4. Multi-family developments adjacent to
lower density or single detached
residential dwellings should:
a) be consistent in form and massing with
the surrounding area;
b) be sited adjacent to major streets to
provide a transition to lower density
uses;
c) concentrate density to the centre of the
development or towards a non-
residential boundary and locate lower
density components adjacent to lower
density residential uses;
d) create a transition in building mass and
form towards the setbacks of the
adjacent neighbourhood;
e) minimize access conflicts;
f) be designed to maximize privacy and
minimize views onto adjoining sites,
particularly for portions of the
development abutting the side yards of
adjacent single detached residential uses.
5. Larger buildings, roof forms and building
frontages should include design
elements and features to:
a) provide variation in the facades to help
reduce the visual length of individual
buildings;
b) have the appearance of a series of
smaller buildings, or as identifiable parts
of a larger concept; and
c) incorporate components that express
strong unit identity and incorporate
direct access to grade for ground-floor
units.
4
Guidelines 8.7.1 A (Continued)
6. New multi-family developments should
use design themes, architectural
features and elements of the
surrounding neighbourhood by
incorporating common elements such as
form, scale, massing and proportion into
the design as a means to reinforce
neighbourhood stability. Examples
include:
a) the articulation of facades, using where
appropriate, elements such as porches,
chimneys, projections, recesses, and
balconies;
b) the placement, size, shape and number
of doors and windows;
c) the location and visual appearance of
garages and/or parking facilities;
d) the selection of appropriate and
compatible roof forms; and
e) the design of hard and soft landscaping.
7. The exposed undersides of balconies and
porches that are visible from a street or
public walkway should be covered with
exterior finishes to provide a finished
appearance to public view.
8. Developments are encouraged to use
the Leadership in Energy and
Environmental Design (LEEDS) standards
in the design of buildings. Techniques
such as rain gardens, vegetated swales,
separation of impervious surfaces,
installing below surface infiltration beds
and tree box filters, and redirecting
water from drain pipes into vegetated
areas are encouraged.
9. Variation in individual unit designs is
encouraged to provide visual interest
and avoid significant repetition either
within a row of townhouses, or between
adjacent rows of units.
5
Guidelines 8.7.1 A (Continued)
10. Garage doors should not face public
streets. Where front facing garage doors
are unavoidable, the impact of garage
doors on the public realm should be
mitigated by:
a) designing residential units with enough
width to include attractive entrances
and windows between garages;
b) recessing garage doors behind the main
building façade;
c) keeping a sufficient width in residential
units to allow the creation of attractive
entrances and fenestration between
garages.
d) grouping garage doors in pairs between
adjacent units to allow building
entrances and facades more prominence
on the street;
e) providing interior spaces that overlook
the street;
f) separating and orienting unit entrances
to the street;
g) providing individual pedestrian
walkways linked to the street;
h) including design details such as transom
windows or glazing in garage doors;
i) a comprehensive landscape plan that
identifies how the visual impact of
garage doors from the street will be
mitigated.
11. Landscaping of rooftops is encouraged
where possible, to provide shared or
private outdoor space for residents and
to provide attractive views for residents
and passersby.
6
Guidelines 8.7.1 B
Vehicle Access, Parking and Circulation
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Parking and servicing should be located
underground or to the rear of buildings,
with access from lanes wherever
possible. Where lane access is not
possible, access should be from streets
via narrow driveways to minimize the
impact on streetscape appearance and
disruption to pedestrian movement.
2. Parking structures should be adequately
screened and architecturally compatible
with the rest of the building. Large
surface parking areas should be divided
into smaller sections to avoid a
monotonous appearance with
landscaping strips, trees, building edges,
pedestrian pathways, and pavement
treatment to enhance their visual
appearance.
3. Developments with large parking areas
should provide a direct pedestrian
pathway system through the parking
area to facilitate convenient and safe
pedestrian access between building
entrances, parked cars, and sidewalks of
adjoining streets. Features such as
special landscaping with trees and
benches, overhead weather protection
and distinct paving should be
incorporated where appropriate.
Pedestrian movement should be
designed to avoid any obstruction by
parked vehicles.
4. Shared vehicle access between adjoining
sites should be considered where access
for parking at the rear of the property is
limited. Joint or shared access should
also be considered between adjoining
developments to minimize disruption of
pedestrian sidewalks and to maximize
landscaping and permeable surfaces.
Integration of driving aisles and
pedestrian walkways between adjacent
sites is also strongly encouraged.
7
Guidelines 8.7.1 B (Continued)
5. Locate parking spaces allocated for
people with disabilities as close as
possible to the main entrance to a
building.
6. Crime Prevention through
Environmental Design (CPTED) principles
should be incorporated into the design
of all parking facilities with convenient,
safe, identifiable and universally
accessible access routes to building
entrances, lobbies or other principal
areas of buildings, and to grade level
from any underground or above ground
parking structures.
7. To increase safety, consider using
electronic security devices and
monitoring systems as a supplement to
natural surveillance opportunities in
parking structures and parking areas.
8. The amount of asphalt surfaces in
parking areas should be minimized by
integrating a variety of paving materials
such as concrete, decorative pavers, etc.
or by using alternate surface treatments.
9. Road grades, streets, lanes, and
driveways should conform to the
existing grades as closely as possible to
ensure minimal disruption of slopes and
vegetation. On steep terrain, roads
should be aligned, wherever possible, to
run parallel rather than counter to,
natural contours and existing grades.
8
Guidelines 8.7.1 C
Landscaping and Open Space
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Landscaping both within and outside the
development should:
a) provide definition for pedestrian
corridors;
b) delineate private and semi private space
from public space;
c) provide adequate screening between
private outdoor spaces;
d) present a pleasing street image;
e) provide suitable buffering between
public road and privacy areas;
f) soften the transition between adjacent
land uses;
g) provide a buffer between residential and
non-residential land uses;
h) create interesting views and focal points
into and out of the site;
i) reinforce design continuity with
neighbouring properties, the scale and
massing of buildings, and the
streetscape by providing consistency in
street trees, plant materials, and other
landscaping elements.
2. Landscape drawings for development
applications should include, but are not
limited to, the following information:
a) the location of mature and existing trees
to be retained or removed,
b) the location of all protective tree
fencing;
c) a grading plan or cross section indicating
finished grade; and
d) a drainage plan for the site.
3. Street trees will be a required
component of all development.
Incorporate deciduous tree species into
streetfront landscaping to define site
boundaries, to enhance public space,
and to permit light penetration in
winter.
9
Guidelines 8.7.1 C (Continued)
4. Energy efficiency and conservation
should be considered in the design of
landscaped areas and in the selection of
plant material. This can be
accomplished through:
a) using native and/or drought-resistant
species;
b) designing the landscaping to moderate
the effect of wind;
c) providing shade in summer;
d) allowing natural drainage to occur
throughout the site;
e) allowing daylight into buildings; and
f) redirecting water from rooftop runoff
and downspouts into vegetated areas or
rain barrels for later irrigation use.
5. Maintain continuous landscaping along
abutting streets and minimize the
number of interruptions such as
driveways and parking entrances.
Continue the sidewalk pavement across
driveways and parking entrances.
6. Create visual landmarks on significant
street corners and at locations of high
visibility. Provide landscaping and
consider incorporating features such as
flag poles, banners, visual art,
ornamental trees, fountains,
architectural elements, and landscape
structures.
7. Any portion of a building site left vacant
for future development should be
landscaped consistent with the
landscape plan for the overall site. The
minimum ground surface treatment
should be lawn. Where possible, the
natural state should be retained for
those portions of a property not being
developed.
10
Guidelines 8.7.1 C (Continued)
8. Identify, preserve and incorporate
stands of mature trees into the overall
site landscaping design. Retain unique
tree species, significant vegetation,
natural landscape features and nesting
areas on a site wherever possible. To
attain this objective, prior to the design
of a project, a detailed survey prepared
by a qualified professional indicating the
location and condition of existing trees
and vegetation on a site should be
conducted and provided to the District
as part of the development application
process.
9. Existing vegetation should be enhanced
with new planting wherever
construction activity has destroyed
vegetation. Replanting with indigenous
or native species is encouraged.
10. Consider incorporating rain gardens and
vegetated swales into parking lot
landscaping to increase the natural
absorption of rainwater runoff from
paved areas into the ground.
11. The height and location of a landscape
screen should ensure that:
a) privacy to adjacent properties is
adequately protected;
b) driving site lines are maintained from
adjacent roads, manoeuvring aisles,
parking lots; and
c) the quality of the streetscape and
outdoor living spaces is enhanced.
12. Maximize the amount of landscaped
areas and minimize the amount of
impervious paved surfaces to increase
the natural absorption of rainwater on a
site.
11
Guidelines 8.7.1 D
Universally Accessible Design
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. All non-vehicular routes should be fully
accessible. Sidewalks and pathways
should be wide enough for
wheelchair/scooters and should include
a tactile strip for the visually impaired.
Curb-cuts and curb let-downs should be
provided in appropriate locations to
facilitate safe, convenient, and direct
access from parking spaces to buildings
for people with disabilities.
2. Building entries should be:
a) clearly addressed with large numbers
visible from the street;
b) directly accessed from the street
without stairs;
c) provided with level areas measuring a
minimum of 1.5m x 1.5m (4.9 ft. x 4.9 ft.)
both inside and outside of doorways;
and
d) provided with weather protection,
exterior lighting, and power-assisted
door openers.
Guidelines 8.7.1 E
Refuse, Recycling and Service Areas
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Integrate vents, mechanical rooms,
mechanical equipment, and elevator
penthouses into the roof design or
screen with materials and finishes
compatible with the overall architectural
design.
2. The design of a roof, placement of
mechanical units and satellite dishes,
etc. should take into account views of
the roof from adjacent buildings.
12
3. Garbage containers and recycling bins
must be:
a) easily accessible;
b) appropriately sized for the building
occupants;
c) contained within roofed/walled
enclosures;
d) incorporated into the overall design of
the development; or
e) screened from public view and
weatherproof and animal-resistant
within the boundaries of each site.
4. Service areas should be internalized
within the development. For
developments with multiple buildings,
common refuse, recycling and service
areas are to be provided. Storage areas
should be located to be convenient and
readily accessible from most buildings or
units on the site. Avoid direct exposure
from public streets and allow for
adequate manoeuvring space for
removal vehicles.
5. Enclose or screen all exterior mechanical
units or equipment, including roof top
units, equipment, and satellite dishes
within upper floors or structures that
from part of the overall design of a
development.
6. Locate building ventilation systems to
minimize noise and exhaust pedestrian
areas, residential units, and outdoor
spaces and locate less sensitive land uses
closer to sources of noise.
7. Buildings should be designed and
constructed maximize sound
attenuation:
a) between units;
b) between public roads and units; and
c) between adjacent land uses and units.
13
Guidelines 8.7.1 F
Signage and Lighting
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. All signage must conform to the Maple
Ridge Sign Bylaw. In the event of a
conflict between the Maple Ridge Sign
Bylaw and these guidelines, the latter
shall take precedent.
2. Signage design, materials and message
should be integrated and complement
the scale and architectural detail of the
building.
3. Pedestrian level lighting is encouraged
along all pedestrian routes and
pedestrian plazas. The lighting should
be pedestrian focused.
4. Lighting should be designed so as to
have no direct source of light visible
from the public right-of-way or adjacent
residential land. Care should be taken to
ensure that lighting glare does not pose
a nuisance to adjacent residences,
pedestrians, or motorists.
Guidelines 8.7.1 G
Bicycle Parking and Storage
Describe how the proposed design complies with each of the
listed guidelines, or describes why a guideline is not complied
with or why it is inapplicable.
1. Short term and long term bicycle parking
facilities should be considered for all
developments. Short term bicycle
parking should be in well-lit locations
and clearly visible from a main building
entrance and/or public roads with
bicycle racks made of sturdy, theft-
resistant material that is securely
anchored to the floor or ground. Longer
term bicycle storage areas provided as
part of a parking structure should be
located close to elevators and access
points.
14
Project Information
To be completed by the Architect on record for this project:
File Number ________________________
Date prepared: _______________________
Architect ________________________ ___________________________
Print Name Signature
DEVELOPMENT DATA SHEET
Existing /Proposed Zone _____________ Date Prepared __________
Proposed (Complies or
state variance needed)
Required Development Data Minimum Required or
Maximum Allowed
LOT AREA* (in square metres)
Gross Total
Less Road Widening / Truncations
Less Park
Net Total
LOT COVERAGE (in % of net lot area)
Total Site Coverage
SETBACKS (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
SETBACKS – Underground Structures (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
BUILDING HEIGHT (in metres/storeys)
Principal
Accessory
NUMBER OF RESIDENTIAL UNITS
Bachelor
One Bedroom
Two Bedroom
Three Bedroom +
Total
GROSS FLOOR AREA (in square metres)
Residential
Retail Commercial
Office Commercial
Other Commercial (Type _________________)
Institutional
Industrial
TOTAL GROSS FLOOR AREA
* If the development site consists of more than one lot, lot dimensions pertain to the entire site.
Proposed (Complies or
variance needed?)
OTHER – state YES or NO for each. If YES describe
on separate sheet.
Heritage Site Tree Survey/Assessment Provided
Watercourse/Steep Slopes Covenants, Stat ROW & Easements
I hereby certify that all the above information is true and correct. I acknowledge that any error or
omissions are the sole responsibility of the undersigned and not the Development and
Environmental Services Department.
Prepared by: ___________________________ __________________________________
Print Name (Please print form and sign above)
NOTE: To be prepared by an Architect for ADP Submission or by an owner/agent (applicant) for Development
Application.
Required Development Data Minimum Required or
Maximum Allowed
DENSITY
# of units/ha (gross)
# of units/ha (net)
Gross Floor Area
Floor Space Ratio (net)
AMENITY SPACE (area in square metres)
Common Activity Area
Useable Open Space
PARKING (number of spaces)
Residential and Multi-Residential Uses
Multi-Residential Town Centre (Bach Units)
Multi-Residential Town Centre (1 Bdr Units)
Multi-Residential Town Centre (Added Bdr)
Commercial Uses
Educational & Assembly Uses
Institutional Use
Industrial Use
Business Park Uses
Comprehensive
Other
Number of spaces for visitors
TOTAL NUMBER OF PARKING SPACES
Number of total for disabled
Number of total (and %) small cars %
Number of total (and %) tandem spaces %
TOTAL OFF STREET LOADING SPACE(S)
BICYCLE PARKING (number of spaces)
Short Term Bicycle Parking
Long Term Bicycle Parking
Lo
t
1
Lo
t
2
ro
a
d
d
e
d
i
c
a
t
i
o
n
11
9
A
A
v
e
.
NO
R
T
H
11
9
A
v
e
.
De
w
d
n
e
y
T
r
u
n
k
R
o
a
d
proposed zone R-2
mi
n
l
o
t
a
r
e
a
3
1
5
s
q
m
mi
n
l
o
t
w
i
d
t
h
9
m
mi
n
l
o
t
d
e
p
t
h
3
0
m
lo
t
a
r
e
a
=
3
6
9
s
q
m
lo
t
a
r
e
a
=
3
6
9
s
q
m
5 units 6 units5 units
common
open
space
vi
s
i
t
o
r
st
a
l
l
s
common
open
space
9.00
2
v
i
s
i
t
o
r
s
t
a
l
l
s
BLOCK A BLOCK B BLOCK C
1
2
.
0
0
1
5.
0
0
PM
T
PM
T
proposed zone R-2
vi
s
i
t
o
r
st
a
l
l
6.00
6.00
5.00
7.50
7.50
15.00 12.00 9.00
7.50
ro
a
d
d
e
d
i
c
a
t
i
o
n
3.00
2.85
ro
a
d
d
e
d
i
c
a
t
i
o
n
11
9
A
A
v
e
.
NO
R
T
H
11
9
A
v
e
.
BLOCK A BLOCK B BLOCK C
ro
a
d
d
e
d
i
c
a
t
i
o
n
11
9
A
A
v
e
.
NO
R
T
H
11
9
A
v
e
.
BLOCK A BLOCK B BLOCK C
Consultant List
Architect
Geoff Lawlor Architecture Inc.
632 -5311 Cedarbridge Way,
Richmond, BC
V6X 0M3
Geoff Lawlor Architect AIBC
tel.: 604-238-3380
cel.: 778-998-6968
Landscape Architect
C Kavolinas & Associates Inc.
2462 Jonquil Court
Abbotsford, BC
V3G 3E8
Clark Kavolinas
Phone: 604-850-2368
GVRD Phone: 604-857-2376
Geotechnical Engineer
Geosolve Consultants Ltd.
--------
Abbotsford, BC
V4N 4P3
Rajinder Bains, P.Eng., M. Eng.
tel., 604-712-1995
Arborist
Mike Fadum & Associates Ltd.
#105 -8277-129 Street
Surrey, BC
V3W 0A6
Mike Fadum
tel.: 778-593-0300
Surveyor
Terra Pacific Land Surveying Ltd.
22371 St Anne Avenue
Maple Ridge, BC
V2X 2E7
Mike Bernemann, BCLS
tel.: 604-463-2509
Civil Engineer
Aplin & Martin Consultants Ltd.
505 -1755 W. Broadway
Vancouver, BC
V6J 4S5
David Laird, P.Eng.
tel., 604-224-6827
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture
Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing
is not to be used for construction unless signed and sealed by the architect.
This design document is prepared solely for the use of the
party with whom Geoff Lawlor Architecture Inc. has entered into a contract with. No representation of any kind is made to
any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED'ISSUED FOR CONSTRUCTION'
AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN
PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-1
site plan & data
1
:
3
0
0
si
t
e
-
g
r
o
u
n
d
l
e
v
e
l
3
1
:
3
0
0
si
t
e
-
u
p
p
e
r
f
l
o
o
r
l
e
v
e
l
2
architectural drawings
Sheet Number Sheet Name
A 1-1 site plan & data
A 1-2 site elevations & sections
A 1-3 roof & unit plans & permeable areas
A 1-4 material & colour palette
A 1-5 detailed site plans
A 1-6 survey
A 1-7 private & common open spaces
A 1-8 floor area calculations
A 1-9 site context
A 1-10 shadow studies
A 2-1 unit type A plans
A 2-2 unit type A sections
A 3-1 unit type B plans
A 3-2 unit type B sections
Project Data
1
:
3
0
0
si
t
e
-
m
a
i
n
f
l
o
o
r
1
proposed townhouse development for:
23682 Dewdney Trunk Road,
(236 B St. / 119 Ave.)
Maple Ridge
rev A, Dec 3/21
sub-division info up-dated
project data up-dated
rev B, March 13/22
units reduced in area
rev C, March 24/22
DP package up-dated -units reduced in size
rev D, March 31/22
road width changed back to 6m
rev E, April 4/22
bio-swale moved to east prop. line
landscape width increased along west
prop. line
rev F, March 31/23
general revisions to accommodate south
road dedication
property line property line
fence
fire hydrant
street lamp
fence
property line property line
fence street lamp
PMT
fences
property
lines
road
dedication
property line
5
A 1-2
property
line
property line
existing grade
6
A 1-2
ma
x
p
e
r
m
i
t
t
e
d
b
u
i
l
d
i
n
g
h
t
.
9.
5
0
5
A 1-2
existing grades
property
lines
road
dedication
property line
119 Ave.
road
dedication
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-2
site elevations &
sections
1 : 100
North1
1 : 100
South2
1 : 300
East3
1 : 300
West4
1 : 100
Section 15
1 : 300
Section 26
1 : 100
East - Block A7
1 : 100
West - Block A8
rev A, Aug 11/21
rear fencing changed & stone veneer
removed from some locations on west
elevation
rev B, March 24/22
DP package up-dated -units reduced in area
rev C, March 31/23
general revisions to accommodate south
road dedication
double car garage
up
entry
co
n
c
.
a
p
r
o
n
patio
fenced
rear yard
property line
cu
r
b
NORTH
recycling & bike st.entry
double car garage
recycling & bike st.patio
fenced
rear yard
co
n
c
.
a
p
r
o
n
up
gate6' fence
6' fence
6' fence
6'
f
e
n
c
e
6'
f
e
n
c
e
gate
pr
i
v
a
t
e
r
o
a
d
la w n
b a sin
la w n
b a sin
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
kitchen
diningliving
po
w
d
e
r
r'm
cl
o
s
e
t
up
dn
NORTH
deck
kitchen
diningliving
po
w
d
e
r
r'
mup
dn
deck
cl
o
s
e
t
closet
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
closet
master
bedroom
bedroom
bedroom
closet
en
s
u
i
t
e
W/D
dn
cl
o
s
e
t
closet
NORTH
master
bedroom
bathroom
bedroom
bedroom
closet
ensuite
W/D
dn
cl
o
s
e
t
closet
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
bathroom
1149.50
m²
east side
180.71
m²
west side
27.52 m²
parking
13.75 m²
parking
NORTH
BL
O
C
K
A
BL
O
C
K
B
BL
O
C
K
C
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-3
roof & unit plans &
permeable areas
1 : 100
typical units A & B - ground floor1
1 : 100
typical units A & B - main floor21 : 100
typical units A & B - upper floor3
rev A, Aug 11/21
kitchen layouts changed
rev B, March 24/22
DP package up-dated -units reduced in area
1 : 300
site permeable areas41 : 300
site - roof plan5
rev C, March 31/23
general revisions to accommodate south
road dedication
A B
F
CH
I
IK C
C
K
H I D
IG
C
C G
I
garage
wall light
unit #, 400mm
grey plastic
exterior finishes
A asphalt shingles -black
B fascia board -painted BM White
C cement fibre board lap siding 6" exposure -painted BM Revere Pewter HC-172
D
E
F trim board -painted BM White
G cement fibre board shingles -painted BM Randolf Stone
H white vinyl window with perimeter trim painted white
I white vinyl window with perimeter trim painted BM Black Satin 2131-10
J glazed entry door painted BM Revere Pewter HC-172 with frame & trim painted BM Black Satin 2131-10
K glazed garage door painted BM Revere Pewter HC-172with frame & trim painted BM Black Satin 2131-10
cement fibre board lap siding 6" exposure -painted BM Dinner Party AF-300
not used
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-4
material & colour palette
1 : 50
Exterior materials & colours1
rev A, Aug 11/21
stone veneer changed to 4" lap siding
between garages & perspective up-dated
rev B, March 24/22
DP package up-dated -units reduced in area
finishes adjusted
rev C, March 31/23
general revisions to accommodate south
road dedication
119 Ave.
un
i
t
t
y
p
e
A
visitor stall
outdoor
amenity
space
NORTH
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
un
i
t
t
y
p
e
B
BL
O
C
K
A
7.50
mail boxes
conc
sidewalk
gate
gate
1.8m fence
co
n
c
a
p
r
o
n
co
n
c
ap
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
landscape
landscape
landscape
landscape
landscape
landscape
landscape
landscape
as
p
h
a
l
t
r
o
a
d
co
n
c
c
u
r
b
co
n
c
ro
l
l
o
v
e
r
cu
r
b
conc. crossing
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
un
i
t
#
1
un
i
t
#
2
un
i
t
#
3
un
i
t
#
4
un
i
t
#
5
9.0 012.0 015.0 0
PMT
0.9m picket
fence
elec. closet
in-ground
infiltration /
detention tank
new fire hydrant
street
lamp
bollard light
visitor stall
visitor stall
elec. closet
49.21
49.06
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
la
n
d
s
c
a
p
e
la
n
d
s
c
a
p
e
1.37
5.50
permeable paving
48.91
49.21
49.06
5.
0
0
5.51
permeable paving
7.00
5.
9
9
1.16:12
9.67%
0.88:12
7.31%
0.74:12
6.19%
0.76:12
6.34%
0.83:126.88%
1.02:12
8.49%
0.37:12
3.12%
0.78:12
6.53%
0.98:12
8.17%
1.15:12
9.59%
49.06
2.
5
0
project sign
bollards
road dedication
1.006
6.00
7.50
landscape
landscape
landscape
landscape
2.50
6.10 6.10
2 parallel parking stalls
6.00
1.06
1.
8
m
f
e
n
c
e
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
1.
8
m
f
e
n
c
e
0.9m picket
fence
48.96
1.
8
m
f
e
n
c
e
0.9m picket
fence
49.11
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
49.11
1.8m fence
7.62
6.00
6.
1
0
39
.
4
1
8.53
block width
bl
o
c
k
l
e
n
g
t
h
8.43
bollard lights
HP
HP
HP 1.8m fence
HP 1.8m fence
HP
HP
NORTH
un
i
t
t
y
p
e
A
outdoor
amenity space
visitor stall
outdoor
amenity
space
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
un
i
t
t
y
p
e
B
BL
O
C
K
B
landscape
co
n
c
pa
t
i
o
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
mail boxes
conc
sidewalk
landscape
landscape
landscape
landscape
landscape
landscape
gate
gate
6'
f
e
n
c
e
as
p
h
a
l
t
r
o
a
d
un
i
t
#
6
un
i
t
#
7
un
i
t
#
8
un
i
t
#
9
un
i
t
#
1
0
co
n
c
c
u
r
b
co
n
c
r
o
l
l
o
v
e
r
c
u
r
b
elec closet
in-ground infiltration /
detention tank
connect to
storm
bollard light
visitor stall
elec closet
la
n
d
s
c
a
p
e
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
5.
0
0
49.07
48.91
49.07
48.91
49.07
48.91
5.50
permeable paving
0.24:12
2.02%
0.45:12
3.77%
0.54:12
4.49%
0.94:12
7.87%
1.01:12
8.45%
1.17:12
9.78%
1.27:12
10.58%
1.06:12
8.83%
0.91:12
7.62%
0.65:12
5.46%
landscape
landscape
landscape
landscape
new fire
hydrant
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
gate
1.
8
m
f
e
n
c
e
0.9m picket
fence 48.96
1.
8
m
f
e
n
c
e
0.9m picket
fence
1.
8
m
f
e
n
c
e
0.9m picket
fence 48.96
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
48.96
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
1.8m fence
4.
2
9
39
.
3
9
8.53
block width
bl
o
c
k
l
e
n
g
t
h
bollard lights
bollard lights
bollard lights
HP
HP
HP
HP
HP
1.8m fence
1.8m fence
1.8m fence
8.41 7.62
5
A 1-2
Lot 1 Lot 2
NORTH
proposed zone CD-1-93
min lot area 371 sq m
min lot width 12 m
min lot depth 24 m
lot area = 368.59 sq m lot area = 368.17 sq m
outdoor amenity space
visitor stall
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
A
un
i
t
t
y
p
e
B
un
i
t
t
y
p
e
A
BL
O
C
K
C
as
p
h
a
l
t
r
o
a
d
co
n
c
a
p
r
o
n
landscape
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
a
p
r
o
n
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
landscape
landscape
landscape
landscape
landscape
gate
landscape
un
i
t
#
1
2
un
i
t
#
1
3
un
i
t
#
1
4
un
i
t
#
1
5
un
i
t
#
1
6
road dedication
119A Ave.
in-ground infiltration /
detention tank
connect to
storm
tree to be retained
tree to be retained
root
protection
zone
tree
protection
fence
tree
protection
fence
new fire hydrant
street lamp
co
n
c
a
p
r
o
n
un
i
t
t
y
p
e
B
un
i
t
#
1
1
co
n
c
pa
t
i
o
co
n
c
pa
t
i
o
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
bi
o
-sw
a
l
e
visitor stall
5.50
9.0012.0015.00
5.50
conc. paving 2.
5
0
2.50
49.29
49.14
49.72
49.57
49.84
49.69
0.07:12
0.61%
0.11:12
0.90%
0.32:12
2.70%
0.68:12
5.65%
0.38:12
3.15%
0.84:12
7.01%
0.27:12
2.22%
0.67:12
5.55%
0.26:12
2.15%
0.70:12
5.82%
0.13:12
1.09%
0.76:12
6.35%
landscape
landscape
landscape
landscape
landscape
1.
8
m
f
e
n
c
e
0.9m picket
fence
1.
8
m
f
e
n
c
e
0.9m picket
fence 49.19
1.
8
m
f
e
n
c
e
0.9m picket
fence
1.
8
m
f
e
n
c
e
0.9m picket
fence
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
1.
8
m
f
e
n
c
e
1.8m fence
0.9m picket
fence
49.74
1.8m fence 1.
8
m
f
e
n
c
e
1.8m fence
7.50
7.50
7.52
block width
bl
o
c
k
l
e
n
g
t
h
8.53
47
.
2
5
bo
l
l
a
r
d
li
g
h
t
s
HP
HP
HP 1.8m fence
HP 1.8m fence
HP 1.8m fence
HP 1.8m fence
8.43 7.63
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-5
detailed site plans
1 : 150
detailed site plan - Block A11 : 150
detailed site plan - Block B21 : 150
detailed site plan - Block C3
rev A, March 24/22
DP package up-dated -units reduced in area
rev B, April 4/22
bio-swale moved to east prop. line
landscape width increased along west
prop. line
rev C, March 31/23
general revisions to accommodate south
road dedication
rev D, May 1/23
block dimensions shown & highlighted
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-6
survey
plot scale is 1:500SITE SURVEYPROPOSED SUB-DIVISION (N.T.S.)
rev A, Dec 3/21
subdivision plan up-dated
un
i
t
#
1
un
i
t
#
2
un
i
t
#
3
un
i
t
#
4
un
i
t
#
5
private open space
= 5.78 sq m
outdoor amenity
space = 44.6 sq m
7.30
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
common open space
= 227.72 sq m
4.37
2.11
2.
7
4
6.
1
1
39
.
4
2
outdoor amenity
space = 69.28 sq m
un
i
t
#
6
un
i
t
#
7
un
i
t
#
8
un
i
t
#
9
un
i
t
#
1
0
unit #11
common open space
= 227.53 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
4.
2
9
16.15
39
.
3
9
un
i
t
#
1
2
un
i
t
#
1
3
un
i
t
#
1
4
un
i
t
#
1
5
un
i
t
#
1
6
9.
4
3
6.73
un
i
t
#
1
1
common open space
= 282.62 sq m
private open space
= 5.78 sq m
48
.
7
4
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
private open space
= 5.78 sq m
6.51
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-7
private & common open
spaces
1 : 150
open space - Block A11 : 150
open space - Block B21 : 150
open space - Block C3
rev B, March 24/22
DP package up-dated -units reduced in area
open areas adjusted
rev C, March 31/23
general revisions to accommodate south
road dedication
43.70 m²
Area
43.70 m²
Area
43.70 m²
Area
43.70 m²
Area
43.70 m²
Area
75.68 m²
Area
2.65 m²
elec closet elec closet not
included in FAR
308.57
m²
Area
301.49
m²
Area
service
areas not
included
in FAR
calc
43.70 m²
Area
43.72 m²
Area
43.70 m²
Area
43.70 m²
Area
43.70 m²
Area
75.60 m²
Area
elec closet not
included in FAR2.62 m²
elec closet
308.63
m²
Area301.67
m²
Area
service
areas not
included
in FAR
calc
43.72 m²
Area
43.72 m²
Area
43.72 m²
Area
43.72 m²
Area
43.72 m²
Area
43.72 m²
Area
92.02 m²
Area
370.33
m²
Area361.90
m²
Area
service
areas not
included
in FAR
calc
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-8
floor area calculations
1 : 150
ground level area block A11 : 150
main floor area block A21 : 150
upper level area block A3
1 : 150
ground level area block B41 : 150
main floor area block B51 : 150
upper level area block B6
1 : 150
ground level area block C71 : 150
main floor area block C81 : 150
upper level area block C9
rev A, March 24/22
DP package up-dated -units reduced in area
rev B, March 31/23
general revisions to accommodate south
road dedication
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
A 1-9
site context
view 1
view 2 view 3 view 4
0.02
view 1
view 2
view 3
view 4
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
1 : 300
site -shadows winter solstice11 : 300
site -shadows spring equinox21 : 300
site -shadows summer solstice31 : 300
site -shadows autumn equinox4 A 1-10
shadow studies
DN
UP
DN
1
A2.2
3
A2.2
2
A2.2
up
re
c
y
c
l
i
n
g
&
bik
e
s
t
o
r
a
g
e
STOR.
6.
7
0
m
0.81 m
0.28 m
1.
5
6
m
patio
double garage
entry
1.23 m 2.50 m 2.50 m
8.
5
3
m
1.
5
0
m
7.
0
4
m
2.
1
3
m
1.
5
0
m
9' - 0"
2.19 m
0.30 m
5.
5
0
m
3'
-
1
1
1
/
4
"
7.87 m
4.93 m
6.53 m
6.
7
0
m
EV charging station
el
e
c
.
s
c
o
o
t
e
r
ch
a
r
g
i
n
g
s
t
a
t
i
o
n
1
A2.2
3
A2.2
LIVING
DINING
KI
T
C
H
E
N
2
A2.2
POWDER
ROOM
closet
up
dn
DW
F
sink
0.64 m
1.22 m
1.
2
2
m
1.
4
2
m
6.
6
6
m
7.
0
0
m
4.
8
3
m
3.
7
5
m
0.
9
1
m
up
12' - 9 3/4"
7.61 m
7.74 m
5.19 m
DECK
bay window
1.
3
6
m
1.96 m 1.06 m0.66 m
4.14 m
1.
5
3
m
8.
5
3
m
3.60 m
guardrail
1.22 m
TV
1
A2.2
3
A2.2
BEDROOM
BEDROOM
MASTER
BEDROOM
EN
-SU
I
T
E
BA
T
H
R
O
O
M
2
A2.2
cl
o
s
e
t
W/D
cl
o
s
e
t
HW
0.
9
9
m
3.20 m
2.
3
2
m
3.21 m
3.
4
9
m
3.10 m
1.
2
5
m
cl
o
s
e
t
2.
2
9
m
0.69 m
0.99 m 1.
7
3
m
0.
6
9
m
li
n
e
n
furnace
0.
9
2
m
1.
0
8
m
2.
4
3
m
0.
9
2
m
2.75 m
bay window
dn
7.74 m
7.74 m
8.
5
3
m
4.14 m 3.60 m
1.53 m
0.62 m 0.
1
9
m
7.
0
0
m
1.
5
3
m
43.72 m²
Area
14.90 m²
Area
61.50 m²
Area
60.08 m²
Area
0.84 m²
Air Handling
0.58 m²
HW
4"
/
1
2
"
4"
/
1
2
"
4"
/
1
2
"
4"
/
1
2
"
8" / 12"8" / 12"
4"
/
1
2
"
gutter
gutter
asphalt shingle roofing
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
unit type A plans
A2.1
1 : 50
basement1
1 : 50
main floor21 : 50
upper floor3
1 : 100
basement area41 : 100
main floor area51 : 100
upper floor area6
rev A, March 24/22
unit plan changed
rev B, Mar 6/23
patio reduced
1 : 50
roof plan7
main floor
3.00 m
upper floor
6.00 m
basement
0.00 m
ceiling
8.44 m
3
A2.2
2
A2.2
max building ht.
9.35 m
0.
9
6
m
0.
9
1
m
9.
5
0
31
'
-
2
"
ht of mid point of
roof pitch
0.
0
4
m
main floor
3.00 m
upper floor
6.00 m
basement
0.00 m
ceiling
8.44 m
1
A2.2
max building ht.
9.35 m
main floor
3.00 m
upper floor
6.00 m
basement
0.00 m
ceiling
8.44 m
1
A2.2
max building ht.
9.35 m
main floor
3.00 m
upper floor
6.00 m
basement
0.00 m
ceiling
8.44 m
3
A2.2
2
A2.2
2.
4
4
m
3.
0
0
m
3.
0
0
m
max building ht.
9.35 m
1'
-
1
0
1
/
8
"
main floor
3.00 m
upper floor
6.00 m
basement
0.00 m
ceiling
8.44 m
1
A2.2
max building ht.
9.35 m
0.
5
6
m
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
unit type A sections
A2.2
1 : 50
Section 111 : 50
Section 221 : 50
Section 33
1 : 50
Section 441 : 50
Section 55
rev A, March 24/22
unit plan changed
DN
UP
DN
1
A3.2
3
A3.2
2
A3.2
up
re
c
y
c
l
i
n
g
&
bi
k
e
s
t
o
r
a
g
e
STOR.
21
'
-
1
1
3
/
4
"
2' - 8"
11"
5'
-
1
1
/
4
"
patio
double garage
entry
4' - 0 1/4"8' - 2 1/2"8' - 2 1/2"
28
'
-
0
"
4'
-
1
0
3
/
4
"
23
'
-
1
"
7'
-
0
"
4'
-
1
0
3
/
4
"
9' - 0"
11 3/4"
7' - 2 1/4"16' - 2"
25' - 11 1/4"
18
'
-
0
1
/
2
"
3'
-
1
1
1
/
4
"
3' - 2"21' - 5"
21
'
-
1
1
3
/
4
"
EV charging station
el
e
c
.
s
c
o
o
t
e
r
ch
a
r
g
i
n
g
s
t
a
t
i
o
n
1
A3.2
3
A3.2
LIVING
DINING
KI
T
C
H
E
N
2
A3.2
POWDER
ROOM
closet
up
dn
DW
F
sink
2' - 1"
4' - 0"
4'
-
0
"
4'
-
7
3
/
4
"
21
'
-
1
0
1
/
4
"
22
'
-
1
1
1
/
2
"
15
'
-
1
0
1
/
4
"
12
'
-
3
3
/
4
"
3'
-
0
"
up
12' - 9 3/4"
24' - 11 1/2"
17' - 0 1/2"
DECK
bay window
4'
-
5
3
/
4
"
6' - 5"3' - 6"2' - 1 3/4"
13' - 7"
5'
-
0
1
/
4
"
28
'
-
0
"
11' - 10 1/4"
9'
-
0
"
6'
-
0
"
9"25' - 11 1/4"
7'
-
1
1
1
/
2
"
ba
y
w
i
n
d
o
w
BEDROOM
BEDROOM
MASTER
BEDROOM
EN
-SU
I
T
E
BA
T
H
R
O
O
M
cl
o
s
e
t
W/D
cl
o
s
e
t
HW
3'
-
3
"
10' - 6"
7'
-
7
1
/
2
"
10' - 6 1/2"
11
'
-
4
1
/
4
"
10' - 2 1/4"
4'
-
1
"
cl
o
s
e
t
7'
-
6
"
2' - 3"
3' - 3"5'
-
8
"
2'
-
3
"
li
n
e
n
furnace
3'
-
0
"
3'
-
6
1
/
2
"
7'
-
1
1
3
/
4
"
3'
-
0
"
9' - 0"
bay window
dn
25' - 5 1/4"
14' - 1"11' - 4 1/4"
9' - 5 3/4"
28
'
-
0
"
13' - 7"11' - 10 1/4"
5' - 0"
3' - 2"7'
-
1
3
/
4
"
5'
-
0
1
/
4
"
22
'
-
1
1
1
/
2
"
7
1
/
2
"
43.72 m²
Area
15.17 m²
Area
61.77 m²
Area
60.36 m²
Area
0.84 m²
air handling
0.56 m²
HW
4"
/
1
2
"
4"
/
1
2
"
4"
/
1
2
"
9" / 12"
9"
/
1
2
"
9"
/
1
2
"
9" / 12"
8" / 12"8" / 12"
4"
/
1
2
"
gutter
gutter
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
unit type B plans
A3.1
1 : 50
basement1
1 : 50
main floor21 : 50
upper floor3
1 : 100
basement area41 : 100
main floor area51 : 100
upper floor area6
rev A, March 24/22
unit plan changed
rev B, Mar 6/23
patio reduced
1 : 50
roof plan7
main floor
9' -10"
upper floor
19' -8 1/4"
basement
0"
ceiling
27' -8 1/4"
3
A3.2
2
A3.2
max building ht.
30' -8"
main floor
9' -10"
upper floor
19' -8 1/4"
basement
0"
ceiling
27' -8 1/4"
1
A3.2
max building ht.
30' -8"
main floor
9' -10"
upper floor
19' -8 1/4"
basement
0"
ceiling
27' -8 1/4"
1
A3.2
max building ht.
30' -8"
main floor
9' -10"
upper floor
19' -8 1/4"
basement
0"
ceiling
27' -8 1/4"
3
A3.2
2
A3.2
8'
-
0
"
9'
-
1
0
"
9'
-
1
0
"
max building ht.
30' -8"
1'
-
1
0
1
/
4
"
1
1
/
2
"
ht. of mid point of roof pitch
main floor
9' -10"
upper floor
19' -8 1/4"
basement
0"
ceiling
27' -8 1/4"
1
A3.2
max building ht.
30' -8"
1'
-
1
0
1
/
4
"
project #
scale
drawn by
checked by
drawing #
seal
drawing title
architect
project
21-112
as shown
Copyright reserved. This plan and design is, and at all times
remains, the exclusive property of Geoff Lawlor Architecture Inc. and cannot be used without the architect's permission.
The General Contractor shall check and verify all dimensions
and report errors and omissions to the architect. This drawing is not to be used for construction unless signed and sealed by
the architect.
This design document is prepared solely for the use of the party with whom Geoff Lawlor Architecture Inc. has entered
into a contract with. No representation of any kind is made to any other party.
GDL
.
Townhouses
23682 Dewdney Trunk Road, Maple
Ridge
NOT TO BE USED FOR CONSTRUCTION UNLESS STAMPED
'ISSUED FOR CONSTRUCTION'AND COUNTERSIGNED BY THE ARCHITECT
DO NOT COPY WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT
ISSUED FOR RE-ZONING, DP &
DVP APPLICATIONS OCT 7/21
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS MARCH
24/22
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
14/23
April 25, 2023
RE-ISSUED FOR RE-ZONING, DP
& DVP APPLICATIONS APRIL
25/23
unit type B sections
A3.2
1 : 50
Section 111 : 50
Section 221 : 50
Section 33
1 : 50
Section 441 : 50
Section 55
rev A, March 24/22
unit plan changed
Monday, May 1, 2023
City of Maple Ridge
11995 Haney Place
Maple Ridge, BC
V2X 6A9
Attn.: Manager of Development and Environmental Services
Re: 23682 Dewdney Trunk R'd., Maple Ridge, 2021-579-RZ
Coordinated Assessment Strategy Statement (CASS)
Dear Sir,
The above project proposes the rezoning of an undeveloped industrial site to residential use comprising
2 single family lots and a 16 unit strata development.
The consultant team is as follows:
Architect and Project Co-ordinator Geoff Lawlor Architect AIBC
Geoff Lawlor Architecture Inc.
Civil Engineer Eric Lum P. Eng.
Aplin & Martin Consultants Ltd.
Landscape Architect Clark Kavolinas BCSLA CSLA
C. Kavolinas & Associates Inc.
Geotechnical Engineer Rajinder Bains P. Eng. M. Eng.
Geosolve Consultants Ltd.
Arborist Tim Vandenberg
Mike Fadum and Associates Ltd.
Surveyor Mike Bernemann BCLS
Terra Pacific Land Surveying Ltd.
We confirm that all recommendations contained in the reports and drawings prepared by ourselves and
the consultants are incorporated into this submission and fully coordinated.
The project design complies with federal and provincial regulations, municipal bylaws and policies, and
municipal guidelines.
Respectfully submitted,
Geoff Lawlor Architect AIBC
Principal, Geoff Lawlor Architect AIBC
Page 1 of 5
City of Maple Ridge
TO:Advisory Design Panel MEETING DATE May 17, 2023
FILE NO:2020-065-DP
SUBJECT:22323, 22335 and 22345 Callaghan Avenue
PURPOSE:
An Advisory Design Panel (the “ADP”) submission has been received for the above cited application and
properties to permit the construction of a six-storey mixed-use building with 74 units and commercial space
on the first floor. The proposed building will replace the existing singe family dwellings on this site.
The rezoning application being processed in conjunction with this proposal was given First Reading by
Council on May 26, 2020. The subject application is proposing a six-storey structure, which exceeds the
height policy for the Port Haney Multi-Family, Commercial and Mixed-Use designation within the Town Centre
Area Plan in the Official Community Plan and as such, the applicant is requesting a text amendment to the
OCP for the increase in height.
The development permit application made to the City is subject to Section 8.11 Town Centre
Development Permit.
BACKGROUND:
Applicant: Studio One Architecture Inc.
Legal Descriptions: Lot 11 Block 6 District Lot 398 Group 1 New Westminster District
Plan 155
Lot 12 Block 6 District Lot 398 Group 1 New Westminster District
Plan 155
Parcel A District Lot 398 Group 1 New Westminster District Plan
82887 Except Part in Plan EPP85876
OCP:
Existing: Port Haney Multi-Family, Commercial and Mixed-Use
Proposed: Port Haney Multi-Family, Commercial and Mixed-Use
Zoning:
Existing: RS-1 (One Family Urban Residential)
Proposed: CD-3-20 (Comprehensive Development)
Surrounding Uses:
North: Use: Single Family Residential
Zone: RS-1 (One Family Urban Residential); currently under application
2019-268-RZ to rezone to RM-2 for an Apartment and Commercial
use
Designation: Port Haney Multi-Family, Commercial and Mixed-Use
Page 2 of 5
South: Use: Vacant
Zone: CRM (Commercial/Residential)
Designation: Port Haney Multi-Family, Commercial and Mixed-Use
East: Use: Callaghan Park
Zone: P-1 (Park and School)
Designation: Park
West: Use: Haney Bypass and Treatment Centre
Zone: P-2 (Special Institutional)
Designation: Low-Rise Apartment
Existing Use of Properties: Single Family Residential
Proposed Use of Properties: Multi-Family Residential and Commercial
Site Area: 2,629 m² (0.65 acres)
Access: Callaghan Street and rear lane
Servicing requirement: Urban Standard
DEVELOPMENT PERMIT AREA:
The development permit application made to the City prompting this submission to the ADP is subject
to the Key Guidelines and the Design Guidelines of Section 8.11 Town Centre Development Permit for
the Port Haney & Waterfront Precinct.
Key Guidelines:
Town Centre Development Permit Area – Port Haney and Waterfront Precinct:
This property is subject to the guidelines of Section 8.11 Town Centre Development Permit Area
Guidelines – Port Haney and Waterfront Precinct of the Official Community Plan that aim to regulate the
form and character of development located within this area. This development respects the key
guideline concepts as outlined in this section, with the applicant response written in italics.
1. Promote Port Haney and the Waterfront as an important heritage, tourism-oriented area.
The selected finishes, colours and treatment of the façade articulation are consistent with Port
Haney’s heritage character.
2. Provide a pedestrian-oriented, mixed use commercial and residential environment.
The development proposes a substantial public realm providing commercial CRU's with a treed
promenade, continuous glazed canopy cover, and areas for seating. The site is well connected to
bicycle routes not requiring travel on major arterial routes- there are local trails accessed from 224th
St to access the Port Haney Wharf, another accessed at nearby Thomas Haney House Museum,
connects to trails within Brickwood Park and the major bike route on 116 Ave. [Ref Appendix B,
attached]
3. Enhance the heritage quality, character and vibrancy of Port Haney and the Waterfront.
Page 3 of 5
There is a local trail accessed around the corner at the foot of 224 St, suitable for bicycles &
pedestrians, that leads to Port Haney Wharf & the Fraser River Waterfront without travel required
on major arterial roads. [Ref Appendix B, attached]
4. Capitalize on important views.
Due to the location of the site, views to the Fraser River and surrounding mountains are anticipated
to be impressive [Ref. Appendix C]. The building has been designed with residences on all faces,
taking full advantage of views to the remarkable setting.
5. Provide outdoor space.
Private outdoor spaces are provided for the units as decks. The public outdoor space is a landscaped
commercial zone surrounding the building. The residences can access the neighbouring park for
relaxation and recreation.
6. Provide climate appropriate landscaping and green features.
The significant landscape proposed is designed primarily to work with the pedestrian experience
both as a commercial zone and as a buffer to traffic along the exposing streets. The significant area
of planting beds provided will assist in rain water retention.
7. Maintain Street Interconnectivity
The development both employs the lane for service & secondary vehicular access but also activates
the lane by wrapping the the commercial glazed frontage back along the lane. There is clear and
safe pedestrian access completely around the site.
Design Guidelines:
The Design Guidelines and a full explanation of how the project complies with them or the reasons why
they are not applicable are attached in Appendix F to this memo.
Page 4 of 5
PLANNING COMMENTS:
1. Proposal:
The proposed project is a 6-story mixed-use development that provides commercial space for the
neighborhood on the ground floor and residential units above. When three land parcels are
combined, they form a trapezoid corner lot with a total of 56.5 M frontage on Callaghan Ave and
50.3 M frontage on Haney Bypass.
2. Context:
The proposed structure of the project is wood frame construction on top of a concrete podium
The podium on the commercial edge is raised to provide a secure and private pedestrian circulation
on a busy street corner for residential entrance and commercial uses. On the ground
floor, the project offers retail stores with great potential to create an active urban edge that will
offer various urban functions to the public. These functions at the street level provide a
pedestrian-oriented environment with activities that add vibrancy to the street.
Storefronts on the ground floor are recessed from the building face and a continuous canopy is
provided above for protection from the elements. Above the commercial podium, vertical elements
clad in brick are arranged in a rhythmic pattern and with the articulation in the façade, help break
the building down into smaller modules. The corner of Callaghan and Haney bypass is glazed in
window wall and the setback from the building façade creates the connection to the commercial
storefronts at grade. The 6th/ floor is set back 3 meters to scale down the height of the building. The
building steps down in mass on the southeast corner to provide a gradual transition to the park.
The podium is clad in textured siding and glass respecting the heritage values; on the upper
floors a mixture of brick, textured siding, and glazed walls were used to enhance the materiality
with modular volumes. Steel and glass will be used for canopies, and wood accents in railings,
trellises, and canopies. Storefront glazing provides transparency to the exterior at street level.
Exposed parking levels will be screened with trellises carrying growing vines, which provide
natural light and ventilation to the floor.
Canopies, signage, lighting, and other pedestrian-scale design elements will be provided along
the street to help define a pedestrian-scale street front. Landscaping and outdoor seating will
offer additional animation and interest.
3. OCP and Zoning Compliance:
The subject site is being rezoned to CD-3-20 (Comprehensive Development), and Development
Data Sheet (Appendix E) analyses the compliance of the project with the applicable zone
regulations.
4. Parking and bicycle storage:
The project provides 9 surface parking stalls for commercial visitors, 7 for residential visitors, and a
total of 74 parking stalls for residential units. This new development provides 74 residential units.
The required parking for the proposed use is analyzed in the Development Data Sheet (Appendix E).
Page 5 of 5
CONCLUSION:
The Planning Department requests that the Advisory Design Panel provide comments on the development
proposal.
______________________________________________
Prepared by: Rene Tardif
The following appendices are attached hereto:
Appendix A Subject map
Appendix B Explanatory letter from Architect (and Landscape Architect if applicable)
Appendix C ADP Submission Form
Appendix D ADP Applicant Checklist (signed by Architect)
Appendix E Development Data Sheet (signed by Architect)
Appendix F DP Area Guidelines Checklist
Appendix G Architectural and Landscaping Plans
DATE: Mar 5, 2020FILE: 2020-065-RZ
22323/35/45 CALLAGHAN AVENUEPID'S: 014-957-876, 010-977-325 & 001-743-937
PLANNING DEPARTMENT
SUBJECT PROPERTIES
´
Scale: 1:2,500 BY: PC
223 ST
Legend
Stream
Ditch Centreline
Edge of River
Indefinite Creek
River
Suite 240 - 388 West 8th Ave. Vancouver BC, V5Y 3X2 Canada T: 604.731.3966
April 26th, 2023
District of Maple Ridge
11995 Haney Place
Maple Ridge, BC, V2X 6A9
Re: Project Description and Design Rationale for proposed residential development at 22323,
22335, and 22345 Callaghan Avenue, Maple Ridge, BC.
PROJECT DESCRIPTION
The proposed project is a 6-story mixed-use development that provides commercial space for
the neighborhood on the ground floor and residential units above. When three land parcels are
combined, they form a trapezoid corner lot with a total of 56.5 M frontage on Callaghan Ave
and 50.3 M frontage on Haney Bypass. To use this frontage on the ground floor the project
offers retail stores with a great potential to create an active urban edge that will offer various
urban functions to the public. The project provides 9 surface parking stalls for commercial
visitors, 7 for residential visitors, and a total of 74 parking stalls for residential units.
This new development provides 74 residential units. The project offers a mix of one, two, and
three bedrooms, providing varying opportunities for prospective families of different sizes.
The main residential entrance is located on Callaghan Ave. with possible access to retail stores.
Surface parking is provided for visitors and commercial customers as well as underground
parking for residents. Commercial and residential parking is conveniently accessible through
Callaghan Ave.
The location offers a 3-minute walk to Port Haney Station to access West Coast Express and
only a 10-minute walk to Haney Place Mall. Moreover, adjacency to British Columbia Highway
No 7 and a 1-minute drive to Lougheed Highway makes the site highly accessible by car.
The site is located next to Callaghan Park, a great location for children and parents, and at
proximate to 224th/ Street, one of the city’s four major Town Centre routes, which connects
the downtown Civic Core to the Waterfront and West Coast Express train station.
ZONING
The proposed development is comprised of three lots at 22323, 22335, and 22345 on Callaghan
Ave. in Town Centre Area, Maple Ridge, with a gross area of 29,874 SQF. A 2.3m road
dedication is required by the Ministry of Transportation along Haney Bypass.
The designated zoning for these parcels is RS-1 (One Family Urban Residential). Rezoning to
CRM is being requested (Commercial/Residential).
Suite 240 - 388 West 8th Ave. Vancouver BC, V5Y 3X2 Canada T: 604.731.3966
THE PROJECT
The proposed structure of the project is wood frame construction on top of a concrete podium
The podium on the commercial edge is raised to provide a secure and private pedestrian
circulation on a busy street corner for residential entrance and commercial uses. On the ground
floor, the project offers retail stores with great potential to create an active urban edge that will
offer various urban functions to the public. These functions at the street level provide a
pedestrian-oriented environment with activities that add vibrancy to the street.
Storefronts on the ground floor are recessed from the building face and a continuous canopy is
provided above for protection from the elements.
Above the commercial podium, vertical elements clad in brick are arranged in a rhythmic
pattern and with the articulation in the façade, help break the building down into smaller
modules. The corner of Callaghan and Haney bypass is glazed in window wall and the setback
from the building façade creates the connection to the commercial storefronts at grade. The
6th/ floor is set back 3 meters to scale down the height of the building.
The building steps down in mass on the southeast corner to provide a gradual transition to the
park.
The podium is clad in textured siding and glass respecting the heritage values; on the upper
floors a mixture of brick, textured siding, and glazed walls were used to enhance the materiality
with modular volumes. Steel and glass will be used for canopies, and wood accents in railings,
trellises, and canopies. Storefront glazing provides transparency to the exterior at street level.
Exposed parking levels will be screened with trellises carrying growing vines, which provide
natural light and ventilation to the floor.
Canopies, signage, lighting, and other pedestrian-scale design elements will be provided along
the street to help define a pedestrian-scale street front. Landscaping and outdoor seating will
offer additional animation and interest.
DP GUIDELINE COMPLIANCE
The project is designed to comply with Development Permit Guidelines to the greatest extent
possible.
The key concepts and guidelines that were followed are:
· The massing is broken down into small-scale architectural elements to complement the
scale of adjacent buildings.
· Variation in exterior finishes, in color, texture, pattern, and scale, also helps reduce the
scale of the building and provides visual interest to the long side elevations.
· The building’s residential levels are located above retail stores.
· Each dwelling unit has a private outdoor area with a min of 5% of the dwelling unit size.
· The 6th floor is stepped back both at the front and back to reduce the scale of the
building.
· High-quality materials and muted color tones form the color palette. No bright colors
were selected, respecting the heritage character of the context.
Suite 240 - 388 West 8th Ave. Vancouver BC, V5Y 3X2 Canada T: 604.731.3966
CRIME PREVENTION THROUGH ENVIRONMENTAL DESIGN
The following strategies have been provided in the design:
· The main entrance will have sufficient lighting and no hidden corners.
· Lighting on the longitudinal building sides is provided in the landscaping. This will
assist in
· The living rooms of the apartments are at the forefront of the façade providing
casual surveillance and eyes on the street
· Parking levels will be painted in light colors and sufficient lighting will be provided.
· Hidden corners in the parking levels have been avoided.
SUSTAINABILITY STRATEGIES
The project will meet or exceed the BC Building Code and Maple Ridge sustainability
requirements.
1. Transportation:
a. Proximity to West Coast Express Train station provides easy access to downtown
Vancouver
b. The project is within walking distance of downtown Maple Ridge and all shopping and
services
c. Provision of secure bike storage.
2. Energy-efficient Building Envelope:
a. High performance, thermally broken windows
b. Wood Frame construction provides a high level of insulation to the envelope
c. The project will be wood frame construction, a renewable resource that also provides a
higher level of thermal bridging mitigation
d. Design for improved thermal comfort
e. Design to reduce overall energy consumption
3. Indoor air quality:
f. Low emitting interior finishes
g. Test indoor air quality prior to occupancy
h. Heat recovery ventilators and electric heating baseboards in all suites
Prepared by:
Studio One Architecture Inc.
Shoghig Tutunjian, Architect AIBC,
Principal
The City
schedule
making y
ADP subm
ADP thro
Applicati
Name of
File num
Address
Current Z
Seeking t
Architect
Submissi
Architect
Landscap
Other Pro
Note.: Th
developm
taken fro
bulletin,
Major
per th
build
Group A (Pa
Group B (Pa
Group C Res
Group D & E
Group F (F1
Adv
of Maple Rid
es for submis
your submiss
mission pack
ough your Fil
ion Informa
Applicant
ber
of site
Zone
to appear be
t Informatio
on will be p
t
pe Architect
ofessional (S
he Architects
ments to the
om AIBC Bull
click here.
Occupancy
he current
ing codes
art 3)
art 3)
sidential
E
: Part 3)
isory Des
dge Advisory
ssion deadlin
sion, contact
kage for you
le Manager w
tion:
_________
_________
_________
_________
efore the AD
on:
resented to
_________
_________
State Name
s are require
e ADP that a
letin 31 Build
Public Assem
Hospital, San
Home for the
Aged
Institutional
Hotel or sim
Commercial
Industrial
sign Pane
y Design Pan
ne dates and
t your File M
ur project. Fo
well in adva
__________
__________
__________
___ Propose
DP on this da
ADP by:
__________
__________
& Role) ____
ed to prepar
re in the Ma
dings Requir
Use
mbly
natorium, or
e
ilar occupancy
el Submis
nel (ADP) me
d for the min
Manager to e
orward your
nce of the d
___________
_____
___________
ed Zone ____
ate ________
___________
___________
__________
re plans and
ajor Occupan
ring the Serv
Type
services
− any o
exce
− any b
exce
− all sc
− any b
capa
− any b
− any b
− any b
− any b
− any b
ssion Req
eets monthly
nimum subm
establish wh
r complete s
deadline date
__________
__________
__________
__________
________
_______
___________
to attend a
ncy categori
vices of an A
es of Building or
s of an architect
one‐storey build
eeding 9 m or gro
building of more
eeding 235 m²; a
chools, any size
building (exclud
acity exceeding 1
building with gro
building contain
building contain
building with gro
building with gro
uest Form
y.Refer to t
mission requ
at constitute
ubmission p
e.
__
__
__
__
__________
nd to presen
es cited in th
Architect. Fo
r Parts of Buildin
t under section 6
Act.
ding with an uns
oss area exceed
e than one store
and
ing veterinary h
12 beds
oss area exceed
ning 5 or more d
ning 11 or more g
oss area exceed
oss area exceed
m
he attached
irements. Be
es a complet
package for t
____
nt all
he Table bel
r the entire
ng requiring the
60 of the Archit
supported span
ing 275 m²;
ey with gross are
ospital) with a
ing 470 m²
welling units
guest rooms
ing 470 m²
ing 470 m²
efore
te
the
ow
e
ects
ea
Studio One Architecture Inc
2020-065-RZ
22323 Callaghan Avenue
RS-1 CRM
May 17, 2023
Shoghig Tutunjian, Architect AIBC
Meredith Mitchell
CITY OF MAPLE RIDGE
ADVISORY DESIGN PANEL
2019 APPLICANT SCHEDULE
Meeting Date Applicant
Deadline
January 16, 2019 December 17, 2018
February 20, 2019 January 28, 2019
March 20, 2019 February 25, 2019
April 17, 2019 March 25, 2019
May 15, 2019 April 18, 2019
June 19, 2019 May 27, 2019
July 17, 2019
June 24, 2019
NO AUGUST MEETING
September 18, 2019
August 26, 2019
October 16, 2019
September 23, 2019
November 20, 2019
October 28, 2019
NO DECEMBER MEETING
ADP Submission Checklist
Application No. _______________________________ File Manager _____________________________
This checklist is being provided to you by your File Manager, to assist in preparing the materials for
submission to the Advisory Design Panel (ADP). Please refer to the ADP Submission Form and the ADP
Requirements Brochure for submission requirements in terms of explanatory letters, plans, supporting
information and specifications on size and numbers of copies to be submitted. Address your questions
to the File Manager or the Planning Liaison to the ADP.
Certification of Complete ADP Submission:
Architect’s Certification:
_____________________________ ___________
Signature Date
Print name
Project Landscape Architect’s Certification:
_____________________________ ___________
Signature Date
Print name
Submission Materials
Required
(File Manager to
indicate if required)
Provided
A. ADP Submission Form (Submitted and signed by Architect)
B. Covering Letter including explanations about:
1. Project description/analysis (Detailed information Required)
2. Architectural and Landscaping Design rationale
(Detailed information Required)
3. Statement in brief about the following:
a. DP Key Concepts Compliance
b. DP Guideline Compliance
c. Stormwater management strategy with emphasis on Tier A
requirements integrated into landscaping plans
d. Public Art / Amenities, etc.
e. Sustainability practices
f. Other __________________________________________
C. Site and Neighbourhood Context
1. Context Review – Context Plan with existing/proposed
buildings and trees, vegetation, roads, existing / proposed
grading, and other major features within the site, on the
abutting properties, the public realm and along the road
allowances / lanes.
2. Photographs of site and surrounding sites.
D. Development Permit Area Checklist
(Note: The Architect is responsible to describe how the project complies with
each guidelines, or if not applicable, a description of why not applicable. Please
use fillable forms on line.)
City of Maple Ridge ADP Submission Checklist (Page 2)
E. Architectural Plans (Site and Building(s)):
1. Site Plan and layout
2. Site sections
3. Streetscape elevation
4. Streetscape elevations with landscaping and boulevard trees
superimposed
5. Shadow analysis
6. Lighting analysis (on building and on site)
7. Floor Plans for all levels, including underground and roof tops
8. Waste collection /recycling (inside of buildings)
9. Storage, including bicycle storage (inside and outside)
10. Building elevation (all sides)
11. Signage (attached to building and free standing)
12. Colours and materials
13. Material board
14. Building sections
15. 3D renderings of site, building(s) and associated landscaping
F. Landscaping Plans:
1. Landscaping plan and layout with specifications and planting
details
2. Storm water management works focused on Tier A
requirements integrated into landscaping plan with details
3. Landscaping details, including public art, signage, lighting, play
and other amenity areas, fences, retaining walls,
4. Waste collection /Recycling (exterior areas/structures)
5. Details for pedestrian amenity and furniture features provided
6. Details for hard surfacing areas / patterns
7. Tree retention and management plan
8. Site sections for lot grading, drainage, landscaping, retaining
walls and relationship to adjacent grades / City roads / lanes
9. Pedestrian, bicycle, equestrian path interconnections
G. Green Building/Sustainability initiatives
H. Engineering-related Information:
1. Site grading plans
I. Other
Rev. March 2018
Town Centre Development Permit Area Guidelines
Port Haney Precinct
Maple Ridge Town Centre
Development Permit Area Guidelines
1
Pursuant with Section 8.11 of the Official Community Plan, development in the Town Centre will be assessed
against the following form and character and green building design guidelines. The guidelines apply to Ground-
Oriented Multi Family; Low-Rise Apartment; Medium & High-Rise Apartment; Flexible Mixed-Use; Town Centre
Commercial; Port Haney Multi-Family, Commercial & Waterfront; and Port Haney Heritage Adaptive Use. See the
guidelines in Section 8.11 of the Official Community Plan for a detailed list and descriptions of development permit
area guidelines.
These guidelines are intended to aid in the review of development permits in the Town Centre and are to be
completed by the architect of record for the project. The project will be reviewed for consistency with the guidelines
by the Planning Department and the Advisory Design Panel.
In the checklist, you are only required to address the guidelines with the icon that relates to your project:
TCC = Town Centre Commercial (commercial developments only)
MU = Mixed-Use (ground-oriented developments, with commercial on the ground level and
either offices or residential above)
MFR = Multi-Family Residential (ground-oriented developments and low-rise, medium-rise, and
high-rise apartments)
Precinct Key Guidelines and Green Building Design Guidelines must also be completed for projects within the Town
Centre.
Development and Design Objectives
The following summarizes the development and design objectives for each section on the following checklist.
A. Building Setbacks, Form, Mass and Height
• To promote a cohesive building style and strong pedestrian oriented urban realm in Maple Ridge Town Centre by
ensuring new buildings, renovations and/or additions have consistent architectural and urban design setbacks,
form, mass, and height.
• To help define the street and sidewalk areas as active public spaces.
B. Building Façades, Materials and Colour
• To ensure additions, renovations and/or new infill projects in the Town Centre have a coherent architectural design
concept where windows, doors, siding material and other façade elements create a pleasing composition
compatible with surrounding buildings, commercial and neighbourhood character.
• To enhance the architectural and massing concepts of a building as well as the quality, character and vibrancy of
the urban environment of the Town Centre through the use of harmonious, quality materials and colours.
• To screen rooftop and ground mounted mechanical equipment and trash storage from public view and thereby
ensure commercial and mixed-used buildings maintain an attractive appearance to the street.
C. Building Site Considerations
• To ensure public outdoor spaces are designed so that they improve use and activities, incorporate universal
access, reduce vandalism, increase safety and provide more attractive, functional outdoor spaces in the Town
Centre.
• To provide street trees and landscape elements that reinforce the ‘urban’ character and vibrancy of the Town
Centre, enrich the pedestrian friendly character of streets in the district, and integrate this important commercial
and higher density residential area with the character and quality of the surrounding residential neighbourhood.
• To ensure parking lots are designed to be accessible, but do not intrude upon the surrounding residential area, nor
the urban, pedestrian-oriented quality of the Town Centre.
• To facilitate off-street parking and car storage at the rear of commercial and mixed-use buildings to maintain street
inter-connectivity, traditional use of the lane as a service street, and to provide a secondary vehicular and
pedestrian throughway in the Town Centre.
• To ensure service loading and mechanical equipment is designed to protect the surrounding businesses and
residential areas from unsightly, noisy and noxious environments.
Town Centre Development Permit Area Guidelines
Checklist
Maple Ridge Town Centre
Development Permit Area Guidelines Checklist
2
Meet Guidelines: Yes No Not
Applicable
A.Building Setbacks, Form, Mass, and Height
A.1 Building Mass and Form
A1.1 Maintain the mass and scale of buildings TCC MU MFR
A1.2 Enhance the block with corner commercial buildings TCC MU
A1.3 Accent corner buildings TCC MU MFR
A1.4 Use pedestrian-scale design elements TCC MU
A1.5 Feature pedestrian amenities TCC MU MFR
A1.6 Design large buildings into smaller modules TCC MU MFR
A1.7 Accommodate street-fronting units TCC MU MFR
A1.9 Ensure appropriate roof pitch TCC MU MFR
A1.10 Use design elements to reduce roof mass and scale TCC MU MFR
A.2 Building Heights
A2.1 Vary building heights TCC MU MFR
A2.2 Maintain alignment of architectural features TCC MU MFR
A2.3 Integrate taller buildings TCC MU MFR
A2.4 Step back taller buildings TCC MU MFR
A2.5 Match building heights at the end of blocks TCC MU MFR
A2.6 Manage phased development TCC MU MFR
A2.7 Protect views TCC MU MFR
A.3 Building Setbacks
A3.1 Place buildings to reinforce sidewalk activity TCC MU MFR
A3.2 Situate building entrances for visibility TCC MU MFR
A3.3 Provide adequate throughways and lighting TCC MU MFR
A3.4 Provide clear sight lines from building foyers and lobbies to allow
visual surveillance TCC MU MFR
A3.5 Separate residential entrances from commercial entrances MU
A3.6 Respect existing buildings TCC MU MFR
A3.7 Distinguish entrances with arrival areas and courtyards TCC MU MFR
A3.8 Locate ramps and entrances in areas that are highly visible TCC MU MFR
Explain how the objectives for Building Setbacks, Form, Mass and Height are met. If you have selected “no” or “not
applicable”, explain why the guideline does not apply to your project or why it cannot be met.
Town Centre Development Permit Area Guidelines
Checklist
Maple Ridge Town Centre
Development Permit Area Guidelines Checklist
3
Meet Guidelines: Yes No Not
Applicable
B. Building Façades, Materials and Colour
B.1 Building Façade
B1.1 Address both sides of the block with corner commercial buildings TCC MU
B1.2 Orient main entrances to face the sidewalk TCC MU MFR
B1.3 Locate windows, doors, and entry features at the street level TCC MU MFR
B1.4 Use a mix of common facade patterns and elements TCC MU MFR
B1.5 Reflect original façades and building scale TCC MU MFR
B1.6 Respect original architectural elements TCC MU MFR
B1.7 Respect old and new design TCC MU MFR
B1.8 Maintain the horizontal rhythm of the street wall TCC MU MFR
B1.9 Provide a visual division between the street level and upper floors TCC MU MFR
B1.10 Include continuous canopies, awnings or overhangs TCC MU
B1.11 Ensure appropriate placement and materials for awnings or canopies TCC MU
B1.13 Use windows to provide ‘eyes on the street’ TCC MU MFR
B1.14 Enhance the public realm TCC MU MFR
B1.15 Ensure signage reflects building scale, character, and materials TCC MU
B.3 Building Materials
B3.1 Enhance the public realm with high quality materials and detailing TCC MU MFR
B3.2 Use materials consistently TCC MU MFR
B3.3 Avoid the use of inappropriate materials TCC MU MFR
B3.6 Use a mix of quality materials TCC MU MFR
B.4 Building Colours
B4.1 Select appropriate colours TCC MU MFR
B4.2 Highlight architectural details, awnings, and entrances TCC MU MFR
B4.3 Ensure a cohesive, consistent colour palette TCC MU MFR
B.5 Screening and Storage
B5.1 Locate and enclose trash, composting, and recycling to keep
out of site of general public TCC MU MFR
B5.2 Screen mechanical equipment TCC MU MFR
B5.3 Avoid conflict with neighbouring properties TCC MU MFR
B5.4 Locate building ventilation systems to minimize noise and exhaust TCC MU MFR
Explain how the objectives for Building Façades, Materials and Colour are met. If you have selected “no” or “not
applicable”, explain why the guideline does not apply to your project or why it cannot be met.
Town Centre Development Permit Area Guidelines
Checklist
Maple Ridge Town Centre
Development Permit Area Guidelines Checklist
4
Meet Guidelines: Yes No Not
Applicable
C. Building Site Considerations
C.1 Public Outdoor Space and Hardscapes
C1.1 Provide public outdoor space TCC MU MFR
C1.2 Ensure public outdoor space is highly visible TCC MU MFR
C1.3 Provide connections between buildings, sidewalks, and outdoor
open spaces TCC MU MFR
C1.4 Ensure universal access for all public spaces TCC MU MFR
C1.6 Provide hardscape elements to enhance the street environment TCC MU MFR
C1.7 Design hardscape elements as part of the building TCC MU MFR
C1.8 Integrate pedestrian amenities with walls and/or landscaped areas TCC MU MFR
C1.9 Provide public art TCC MU MFR
C1.10 Ensure new elements complement existing TCC MU MFR
C1.12 Provide smooth routes TCC MU MFR
C1.13 Ensure barrier-free access TCC MU MFR
C.2 Parking and Parking Lots
C2.1 Provide required parking underground, where feasible TCC MU MFR
C2.2 Screen large surface parking lots while maintaining surveillance TCC MU MFR
C2.3 Maximize pedestrian safety within parking lots TCC MU MFR
C2.4 Provide visible signage TCC MU MFR
C2.5 Consider developing underground parking garages TCC MU MFR
C2.7 Locate parking lot equipment away from the public street TCC MU MFR
C.3 Lanes, Service and Loading Areas
C3.1 Use lanes for service, parking access and loading TCC MU MFR
C3.2 Utilize lanes as secondary vehicular and pedestrian throughways TCC MU MFR
C3.3 Strengthen visual access of the lane TCC MU MFR
C3.5 Consider lanes as a community amenity TCC MU MFR
C3.7 Locate loading and service areas away from the street front TCC MU MFR
C3.8 Separate loading from parking and pedestrian paths TCC MU MFR
C3.9 Screen loading areas TCC MU
C.4 Street Trees and Landscape
C4.2 Use the right species TCC MU MFR
C4.8 Maintain sight lines TCC MU MFR
Explain how the objectives for Building Site Considerations are met. If you have selected “no” or “not applicable”,
explain why the guideline does not apply to your project or why it cannot be met.
Town Centre Development Permit Area Guidelines
Port Haney Precinct Key Guidelines
Maple Ridge Town Centre
DP Part I: Key Guideline Concepts for the Port Haney Precinct
5
KEY GUIDELINE CONCEPTS
1. Promote Port Haney and the Waterfront as an important heritage, tourism-oriented area
a.Is the proposed development consistent with Port Haney’s heritage character?
•Consistent: Yes No
Explain:
2.Provide a pedestrian-oriented, mixed-use commercial and residential environment
b.Does the development enhance pedestrian and cycling activities in Port Haney and interconnections to the
other areas of the Town Centre?
•Consistent: Yes No
Explain:
3. Enhance the heritage quality, character and vibrancy of Port Haney and the Waterfront
c.Does proposed development take advantage of opportunities to access the Fraser River waterfront?
•Consistent: Yes No Not Applicable
Explain:
4. Capitalize on important views
d.Does the proposed development take advantage of views to the Fraser River waterfront and of the
mountains?
•Consistent: Yes No Not Applicable
Explain:
e.Have the important views of existing buildings been considered in relation to the proposed development?
•Consistent: Yes No Not Applicable
Explain:
5.Provide outdoor space
f.Is private and public outdoor space provided as part of development proposal?
•Consistent: Yes No Not Applicable
Explain:
g.Are outdoor spaces designed to accommodate a wide use of activities, incorporate universal access, reduce
vandalism, and increase safety?
•Consistent: Yes No Not Applicable
Explain:
Town Centre Development Permit Area Guidelines
Port Haney Precinct Key Guidelines
Maple Ridge Town Centre
DP Part I: Key Guideline Concepts for the Port Haney Precinct
6
6. Provide climate appropriate landscaping and green features
h. Are the landscape elements designed to enrich the pedestrian environment, moderate the internal building
climate, manage stormwater on site, and reference the architectural quality of the building(s)?
• Consistent: Yes No Not Applicable
Explain:
7. Maintain Street Interconnectivity
i. Does proposed development maintain street interconnectivity and the use of the lane as a service street and
secondary vehicular and pedestrian throughway?
• Consistent: Yes No Not Applicable
Explain:
j. Is required parking provided underground?
• Consistent: Yes No Not Applicable
Explain:
Town Centre Development Permit Area Guidelines
Green Building Techniques
Maple Ridge Town Centre
Green Building Design Guidelines
7
A. Building Setbacks, Form, Mass, and Height
A1.8 Design flexible ground-floor unit spaces in commercial and mixed-use buildings.
• Consistent: Yes No
Explain:
A1.11 Accommodate roof gardens, trellises, and green features.
• Consistent: Yes No
Explain:
A2.8 Site buildings to capitalize on daylight and solar opportunities.
• Consistent: Yes No
Explain:
A2.9 Protect solar access to surrounding buildings and minimize wind tunnel effects.
• Consistent: Yes No
Explain:
B. Building Façades, Materials, and Colour
B1.12 Use exterior shading devices to block summer sun.
• Consistent: Yes No
Explain:
B2.1 Design outdoor lighting to minimize light pollution.
• Consistent: Yes No
Explain:
B2.2 Encourage energy efficient lighting.
• Consistent: Yes No
Explain:
B3.4 Select environmentally responsible building materials.
• Consistent: Yes No
Explain:
B3.5 Minimize the use of unsustainable building materials.
• Consistent: Yes No
Explain:
Town Centre Development Permit Area Guidelines
Green Building Techniques
Maple Ridge Town Centre
Green Building Design Guidelines
8
B3.7 Consider life-cycle cost.
• Consistent: Yes No
Explain:
C. Building Site Considerations
C1.5 Locate outdoor plazas to capture the sun.
• Consistent: Yes No
Explain:
C1.11 Use materials that are functional, durable and include recycled or salvaged content.
• Consistent: Yes No
Explain:
C1.14 Encourage use of infiltration techniques.
• Consistent: Yes No
Explain:
C2.6 Locate adequate priority parking in visible areas convenient to entrances.
• Consistent: Yes No
Explain:
C2.8 Use permeable pavement and infiltration devices on appropriate sites.
• Consistent: Yes No
Explain:
C2.9 Provide shade trees and landscaping.
• Consistent: Yes No
Explain:
C2.10 Provide secure and sheltered bicycle storage facilities for short-term uses.
• Consistent: Yes No
Explain:
C2.11 Provide long-term bicycle parking.
• Consistent: Yes No
Explain:
Town Centre Development Permit Area Guidelines
Green Building Techniques
Maple Ridge Town Centre
Green Building Design Guidelines
9
C2.12 Provide end-of-trip facilities.
• Consistent: Yes No
Explain:
C3.4 Minimize impervious paving of the lane.
• Consistent: Yes No
Explain:
C3.6 Respect existing grades.
• Consistent: Yes No
Explain:
C4.1 Plant street trees.
• Consistent: Yes No
Explain:
C4.3 Minimize use of high maintenance plants.
• Consistent: Yes No
Explain:
C4.4 Maximize the use of native and climate appropriate species.
• Consistent: Yes No
Explain:
C4.5 Consider the inclusion of community gardens.
• Consistent: Yes No
Explain:
C4.6 Design and place landscape to facilitate year round moderation of the internal building climate.
• Consistent: Yes No
Explain:
C4.7 Minimize erosion potential.
• Consistent: Yes No
Explain:
Town Centre Development Permit Area Guidelines
Green Building Techniques
Maple Ridge Town Centre
Green Building Design Guidelines
10
C4.9 Provide adequate landscape maintenance.
• Consistent: Yes No
Explain:
C4.10 Consider incorporating landscape plantings for green features.
• Consistent: Yes No
Explain:
C4.11 Incorporate low impact stormwater features.
• Consistent: Yes No
Explain:
C4.12 Consider rainwater collection for re-use.
• Consistent: Yes No
Explain:
C4.13 Use natural plantings and green space to support habitat.
• Consistent: Yes No
Explain:
C4.14 Retain existing mature trees.
• Consistent: Yes No
Explain:
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
ISSUED FOR ADP - MAY 17TH, 2023
MIXED-USE DEVELOPMENT - 22323, 22335, & 22345 CALLAGHAN AVE., MAPLE RIDGE, BC
17
0
2
5
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
PROJECT STATISTICS
PROJECT STATISTICS
A0.1
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
PROJECT RATIONALE
A0.2
SITE CONTEXT:
The proposed development is comprised of three lots at 22323, 22335 and 22345 on
Callaghan Ave. in Town Centre Area , Maple Ridge, with gross area of 29,874 SQF. (Pic 01)
a 2.3m road dedication is required by the Ministry of Transportation along Haney Bypass.
(Pic 02)
The designated zoning for these parcels is RS-1 (One Family Urban Residential) . The client
is requesting to rezone theses three parcels based on CRM zoning (commercial/Residential).
(Pic 03).
The site is located next to Callaghan Park , a great location for children and parents, and at
proximate to 224th Street, one of the four major Town Centre routes of the city, which connects the
downtown Civic Core to the Waterfront and West Coast Express train station. The location offers a
3-minutes walk to Port Haney Station to access West Coast Express and only 10 minutes
walk to Haney Place Mall. Moreover, adjacency to British Columbia Highway No 7 and
1-minute drive to Lougheed Highway makes the site highly accessible by car. (Pic04)
MAJOR ATTRACTION
ARTERIAL ROADS
COLLECTOR / DISTRIBUTOR
WEST COAST EXPRESS
N
ROAD DEDICATION
SITE TO BE DEVELOPED
EXISTING PARCELS FOR REZOING
THE PROJECT:
The proposed project is a 6-story mixed-use development that provides commercial space
for the neighborhood on the ground floor and residential units above. When three land
parcels are combined, they form a trapezoid corner lot with a total of 56.5 M frontage on
Callaghan Ave and 50.3 M frontage on Haney Bypass. To use this frontage on the ground
floor the project offers retail stores with a great potential to create an active urban edge that
will offer various urban functions to the public. The project provides 9 surface parking stalls
for commercial visitors, 7 for residential visitors, and a total of 74 parking stalls for
residential units.
This new development provides 74 residential units. The project offers a mix of one, two, and
three bedrooms, providing varying opportunities for prospective families of different sizes.
The main residential entrance is located on Callaghan Ave. with possible access to retail
stores. Surface parking is provided for visitors and commercial customers as well as
underground parking for residents. Commercial and residential parking is conveniently
accessible through Callaghan Ave.
DESIGN RATIONALE:
The proposed structure of the project is wood frame construction on top of a concrete podium
The podium on the commercial edge is raised to provide a secure and private pedestrian
circulation on a busy street corner for residential entrance and commercial uses. On the
ground floor the project offers retail stores with a great potential to create an active urban edge
that will offer various urban functions to the public. These functions at street level provide a
pedestrian-oriented environment with activities that add vibrancy to the street.
Storefronts on ground floor are recessed from the building face and a continuous canopy
provided above for protection from the elements.
Above the commercial podium, vertical elements clad in brick are arranged in a rhythmic
pattern and with the articulation in the façade, help break the building down into smaller
modules. The corner of Callaghan and Haney bypass is glazed in window wall and the setback
from the building façade creates the connection to the commercial storefronts at grade. The
6th floor is set back 3 meters to scale down the height of the building.
The building steps down in massing on the southeast corner to provide a gradual transition to
the park. (Pic 5,6)
The podium is clad in textured siding and glass respecting to the heritage values; on the upper
floors a mixture of brick, textured siding , and glazed walls were used to enhance the
materiality with modular volumes. Steel and glass will be used for canopies, and wood accents
in railings, trellises and canopies. Storefront glazing provides transparency to the exterior at
street level. Exposed parking levels will be screened with trellises carrying growing vines,
which provide natural light and ventilation to the floor.
Canopies, signage, lighting and other pedestrian scale design elements will be provided along
the street to help define a pedestrian scale street front. Landscaping and outdoor-seating will
offer additional animation and interest.
Pic04
Pic01 Pic02
CONTINUOUS CANOPY
SYNCOPATIVE VOLUMES
MODULAR URBAN BAYS
PEDESTRIAN PERMEABILITY
RAISED PODIUM
TRASPARENT SURFACE
PEDESTRIAN ACCESS
PARKING ACCESS
HORIZONTAL BREAKS
COMMERCIAL EDGE
HANEY
B
Y
P
A
S
S
CALLAG
H
A
N
A
V
E
.
CAL
L
A
G
H
A
N
A
V
E
.
CAL
L
A
G
H
A
N
P
A
R
K
1.BURGUNDY BRICK 2.HARDIE SIDING
3.LIGHT ASH SOFFIT
1
2
3
3
1
2
3
4
Pic05
Pic06
Pic03SITE LOCATION WITH CURRENT ZONING
SCALE: NTS
PROJECT RATIONALE
N N N
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
MATERIAL BOARD
A0.3
CAL
L
A
G
H
A
N
A
V
E
.
BURGUNDY BRICK
SCALE: NTS
MATERIAL BOARD
H
A
N
E
Y
B
Y
P
A
S
S
.
1 HARDIE SIDING LIGHT ASH SOFFIT23
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
LOCATION PLAN
& EXISTING CONTEXT
A0.4
EXISTING AERIAL VIEW
PROPOSED DEVELOPMENT AERIAL VIEW
AB
OFFICIAL COMMUNITY PLAN
SITE LOCATION
EXISTING AERIAL VIEW C. EXISTING STREETSCAPE
BA
D
C
A. EXISTING STREETSCAPE - CALLAGHAN PARK B. EXISTING STREETSCAPE
D. EXISTING STREETSCAPE - CALLAGHAN PARK VIEW AT LANE
SCALE: NTS
CONTEXT & SITE PHOTOS
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SHADOW ANALYSIS
A0.5
MARCH 21ST 10:00AM MARCH 21ST 12:00PM MARCH 21ST 2:00PM
JUNE 21ST 2:00PMJUNE 21ST 12:00PMJUNE 21ST 10:00AM
SHADOW ANALYSIS
N
SCALE: NTS
UP
DN
DN
16
M
R
A
M
P
@
5
%
DN
21'
[6.4M]
11'-2"
[3.4M]
97'
[29.6M]
13'-10"
[4.2M]
23
'
-
1
1
"
[7
.
3
M
]
76'-11"
[23.5M]
21'-6"
[6.5M]
67'-2"
[20.5M]
48'-9"
[14.9M]
14
'
-
8
"
[4
.
5
M
]
38
'
[1
1
.
6
M
]
52
'
-
1
1
"
[1
6
.
1
M
]
2
8
'
R
A
M
P
@
5
%
D
N
EL. 79.00'
(24.10M)
CALLAGHAN PARK
H
A
N
D
I
C
A
P
A
C
C
E
S
S
P1
RS-1CRMRS-1RS-1C-3
13
'
-
1
"
[4
.
0
M
]
11
0
'
-
8
"
[3
3
.
7
M
]
EL. 77
.
8
3
'
(23.7
2
M
)
EL. 77
.
8
3
'
(23.7
2
M
)
EL. 80.50'
(24.53M)
EL. 77
.
0
0
'
(23.4
7
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
14'-9"
[4.5M
]
9'-10"
[3.0M]
6'
[1.8M]
5'-10"
[1.8M]
9'-
1
0
"
[3
.
0
M
]
2'-
6
"
[0
.
8
M
]
7'-6"
[2.3M
]
7'-
1
0
"
[2
.
4
M
]
18
'
[5
.
5
M
]
16
'
-
9
"
[5
.
1
M
]
15
'
-
2
"
[4
.
6
M
]
22'-3"
[6.8M
]
4'
[1
.
2
M
]
13
'
-
2
"
[4
.
0
M
]
TOP. 1
5
2
.
5
0
'
(46.4
8
M
)
TO RESIDENTIAL PARKING U/G TO COMMERCIAL VISITOR /PARKING
EX.E
L
.
7
9
.
9
8
'
(24.3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
15
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23.93
M
)
EX.EL.
7
7
.
1
0
'
(23.50
M
)
EX.EL. 82.67'
(25.
2
0
M
)
H
A
N
E
Y
B
Y
P
A
S
S
CALLAGHAN AVENUE
LANE
EX.EL.
7
7
.
1
0
'
(23.50
M
)
20'-9
"
[6.3
M
]
EL. 80.50'
(24.53M)
13
'
-
1
"
[4
.
0
M
]
7.5' R
A
M
P
@
1
0
%
DN
EL. 79.73'
(24.30M)
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
TOP. 1
5
2
.
5
0
'
(46.4
8
M
)
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
SURFACE PARKING BELOW
FIRE DEPT.
CONNECT.
FIRE DEPT ANNUNCIATOR
PANEL IN LOBBY, SEE
GROUND FL PLAN
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SCALE 1:200 ( 24x36 Format )
SITE PLAN
SITE PLAN
SOA
1:200
A1.1
N
EX.E
L
.
7
9
.
9
8
'
(24.3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
1
5
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23.9
3
M
)
EX.EL
.
7
7
.
1
0
'
(23.50
M
)
EX.EL. 82.67'
(25.20M)
H
A
N
E
Y
B
Y
P
A
S
S
CALLAGHAN AVENUE
LANE
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
20'-
9
"
[6.3
M
]
69 PARKING STALLS
UP
6M
R
A
M
P
@
8.
3
3
%
U
P
15
M
R
A
M
P
@
1
2
.
0
%
UP
EL
.
6
8
.
5
0
'
(20.90M)
EL.
7
0
.
2
1
'
(21
.
4
0
M
)
EL. 68.50'
(20.90M)
EL. 68.50'
(20.90M)
UP
UP
H/C
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
94'-10"
[28.9 m]
4'-0"
[1.2 m]
4'-1"
[1.2 m]
4'-0"
[1.2 m]
4'-0"
[1.2 m]
4'-1"
[1.2 m]
4'-0"
[1.2 m]
4'-0"
[1.2 m]
4'-1"
[1.2 m]
4'-0"
[1.2 m]
4'-0"
[1.2 m]
4'-9"
[1.4 m]
4'-0"
[1.2 m]
49'-0"
[14.9 m]
1'
-
0
"
[0
.
3
m
]
8'
-
2
"
[
2
.
5
m
]
8'
-
2
"
[
2
.
5
m
]
8
'
-
2
"
[2
.
5
m
]
1'
-
0
"
[
0
.
3
m
]
8'
-
2
"
[
2
.
5
m
]
8
'
-
2
"
[2
.
5
m
]
8'
-
2
"
[
2
.
5
m
]
1'
-
0
"
[
0
.
3
m
]
7'
-
1
0
"
[2
.
4
m
]
7'
-
1
0
"
[
2
.
4
m
]
7'
-
1
0
"
[
2
.
4
m
]
1'
-
0
"
[0
.
3
m
]
7
'
-
1
0
"
[
2
.
4
m
]
7'
-
1
0
"
[2
.
4
m
]
7'
-
1
0
"
[
2
.
4
m
]
1'
-
0
"
[
0
.
3
m
]
1
0
1
'
-
0
"
[
3
0
.
8
m
]
7'-10"
[2.4 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
63'-11 5/8"
[19.5 m]
187'-4"
[57.1 m]
10'-8"
[3.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
9'-6"
[2.9 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
3'-5"
[1.0 m]
20'-0"
[6.1 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
10'-8"
[3.3 m]
8'-1"
[2.5 m]
16'-0"
[4.9 m]
0'-7"
[0.2 m]
4'-
3
"
[1
.
3
m
]
64
'
-
7
"
[1
9
.
7
m
]
1'
-
0
"
[0
.
3
m
]
18
'
-
0
"
[5
.
5
m
]
TY
P
.
24
'
-
7
"
[7
.
5
m
]
Ma
n
e
u
v
e
r
i
n
g
A
i
s
l
e
18
'
-
0
"
[5
.
5
m
]
TY
P
.
1'
-
1
0
"
[0
.
6
m
]
63
'
-
5
"
[1
9
.
3
m
]
1'
-
0
"
[0
.
3
m
]
18
'
-
0
"
[5
.
5
m
]
TY
P
.
24
'
-
7
"
[7
.
5
m
]
Ma
n
e
u
v
e
r
i
n
g
A
i
s
l
e
18
'
-
0
"
[5
.
5
m
]
TY
P
.
18
'
-
0
"
[5
.
5
m
]
TY
P
.
5'
-
6
"
[1
.
7
m
]
24
'
-
7
"
[7
.
5
m
]
Ma
n
e
u
v
e
r
i
n
g
A
i
s
l
e
18
'
-
0
"
[5
.
5
m
]
TY
P
.
1'-
0
"
[0
.
3
m
]
1'-
0
"
[0
.
3
m
]
7'-
1
0
"
[2
.
4
m
]
7'
-
1
0
"
[2
.
4
m
]
1'-
0
"
[0
.
3
m
]
7'-
4
"
[2
.
2
m
]
15'-4
"
[4.7
m
]
8'-2"
[2.5
m
]
8'-2"
[2.5
m
]
7'-0"
[2.1
m
]
1
7
'
-
4
"
[
5
.
3
m
]
3
2
'
-
1
1
3
/
8
"
[
1
0
.
0
m
]
1
8
'
-
0
"
[
5
.
5
m
]
T
Y
P
.
1'
-
0
"
[
0
.
3
m
]
24'-7
"
[7.5
m
]
Mane
u
v
e
r
i
n
g
A
i
s
l
e
16'-0
"
[4.9
m
]
TYP.
1'-0"
[0.3
m
]
18'-0
"
[5.5
m
]
TYP.
1'-0"
[0.3
m
]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
3'-7"
[1.1 m]
7'-1"
[2.2 m]
20'-0"
[6.1 m]
MECHANICAL
ELECTRICAL
SERVICE ROOM
BIKE STORAGE: 19
STORAGE ROOM: 74
VEST.
DETENTION TANK
P.M.T
P1 ELEVATOR
LOBBY
2'-0"
[0.6 m]
13
0
'
-
8
"
[3
9
.
8
m
]
261'-11 5/8"
[79.8 m]
1
5
2
'
-
7
3
/
8
"
[
4
6
.
5
m
]
155'-5 3/8"
[47.4 m]
8'-11 3/8"
[2.7 m]
19'
-
1
1
7
/
8
"
[6.
1
m
]
19
'
-
8
"
[6
.
0
m
]
49
'
-
2
"
[1
5
.
0
m
]
19
'
-
8
"
[6
.
0
m
]
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SCALE 1:100 ( 24x36 Format )
U/G PARKING PLAN
U/G PARKING PLAN
1:100
A1.2
N
DN
DN
LOADING
RESIDENTIAL LOBBY
CRU # 1
CRU # 3
CRU # 4
CRU # 5
16
M
R
A
M
P
@
5
%
6M
R
A
M
P
@
8
.
3
3
%
15
M
R
A
M
P
@
1
2
.
0
%
109.6 SM
153.9 SM
104.3 SM
102.6 SM
RESIDENTIAL REFUSE AND RECYCLING
DN9'
-
1
0
"
[3
.
0
m
]
11'-9
"
[3.6
m
]
CRU # 2
185.1 SM
6'
-
1
0
1
/
8
"
[2
.
1
m
]
5'-
0
"
[1
.
5
m
]
1
1
0
'
-
7
1
/
2
"
[
3
3
.
7
m
]
EX.E
L
.
7
9
.
9
8
'
(24
.
3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
1
5
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23.9
3
M
)
EX.EL
.
7
7
.
1
0
'
(23.50
M
)
EX.EL. 82.67'
(25.20M)
H
A
N
E
Y
B
Y
P
A
S
S
LANE
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
20'-9
"
[6.3
M
]
36
'
-
1
1
/
2
"
[1
1
.
0
m
]
46
'
-
6
1
/
2
"
[1
4
.
2
m
]
28'-0
7
/
8
"
[8.6
m
]
14'-6
1
/
4
"
[4.4
m
]
14'-9
"
[4.5
m
]
43'-7 1/8"
[13.3 m]
8'-3"
[2.5M]
27
'
-
1
1
/
2
"
[8
.
3
m
]
7'-8 3/4"
[2.4 m]
10
'
-
0
"
[3
.
0
m
]
24'-0"
[7.3 m]
EX.E
L
.
7
7
.
0
0
'
( 23.
4
7
M
)
EL. 80.50'(24.53M)
2
8
'
R
A
M
P
@
5
%
D
N
EL. 80.50'
(24.53M)
EL. 80.50'
(24.53M)
38
'
-
9
1
/
2
"
[1
1
.
8
m
]
29'-9 1/8"
[9.1 m]
110'-5"
[33.7M]
7'
[2.1M]
3
9
'
-
9
"
[1
2
.
1
m
]
2
3
'
-
4
"
[7
.
1
m
]
1
3
'
-
0
"
[
4
.
0
m
]
25'-1
"
[7.6
m
]
18
'
-
0
"
[5
.
5
m
]
25'-8 1/4"
[7.8 m]
59'-8 7/8"
[18.2 m]
72'-9"
[22.2M]
16
'
-
6
"
[5
.
0
m
]
9'-10"
[3.0 m]
4'-2 7/8"
[1.3 m]
2'-0"
[0.6
m
]
4'-9"
[1.4
m
]
EX.E
L
.
7
7
.
8
3
'
( 23.
7
2
M
)
EX.E
L
.
7
7
.
8
3
'
( 23
.
7
2
M
)
EL. 8
0
.
5
0
'
( 24
.
5
3
M
)
EL. 80.50'
( 24.53M)
EX.EL
.
7
6
.
0
7
'
( 23.
1
9
M
)
EL. 80.50'
(24.53M)
EL. 80.50'
(24.53M)
EX.E
L
.
8
0
.
5
0
'
( 24
.
5
3
M
)
EX.EL.
7
9
.
0
0
'
( 24.1
0
M
)
LINE OF CANOPY
ABOVE
LINE OF BUILDING
ABOVE
12'-0
1
/
8
"
[3.7
m
]
16'-9"
[5.1M
]
17
'
-
4
3
/
8
"
[5
.
3
m
]
8'
-
0
"
[2
.
4
m
]
9'-
4
1
/
4
"
[2
.
9
m
]
41'-8 3/4"
[12.7 m]
53
'
-
1
0
1
/
2
"
[1
6
.
4
m
]
41'-9"
[12.7M]
8"
[0.2M]
2'-8"
[0.8M]
1
1
0
'
-
8
"
[3
3
.
7
M
]
39'-1"
[11.9M]
5'-0"
[1.5
m
]
6'-11 7/8"
[2.1 m]
0'-8"
[0.2 m]
20'-0"
[6.1 m]
13'-3 7/8"
[4.1 m]
60
'
-
6
1
/
2
"
[1
8
.
5
m
]
71
'
-
6
3
/
4
"
[2
1
.
8
m
]
LINE OF BUILDING
ABOVE
LINE OF BUILDING
ABOVE
BLDG
ABOVE
LINE OF BUILDING
ABOVE
LINE OF CANOPY
ABOVE
DN
UP
TO RESIDENTIAL
PARKING U/G
5'
-
0
"
[1
.
5
m
]
4'-0"
[1.2
m
]
7'-6
3
/
4
"
[2.3
m
]
TO COMMERCIAL/
VISITOR PARKING
2'-
0
1
/
8
"
[0
.
6
m
]
T.O
.
P
A
R
.
8
0
.
5
0
'
T.OP
A
R
(
2
4
.
5
3
M
)
3 BIKE RACKS
7 BIKE RACKS
9 BIKE RACKS
8 BIKE RACKS
29'-5 1/8"
[9.0 m]
4
4
'
-
2
1
/
2
"
[
1
3
.
5
m
]
3
4
'
-
1
1
/
2
"
[1
0
.
4
m
]
1
4
'
-
0
1
/
8
"
[
4
.
3
m
]
2
9
'
-
6
1
/
2
"
[
9
.
0
m
]
31'-4"
[9.5M
]
1
4
'
-
1
0
1
/
8
"
[
4
.
5
m
]
DN
EL. 80.50'
( 24.53M)
2 x COMM
5'
[1
.
5
M
]
COMMERCIAL REFUSE
AND RECYCLYING
19'-2 1/4"
[5.8 m]
4'-11 3/4"
[1.5 m]
16
'
-
5
"
[5
.
0
m
]
VEST.
BIKE STORAGE
7'-6"
[2.3
m
]
RAMP
@ 10%
DE. 79
.
7
3
'
( 23.3
0
M
)
80.2
8
'
[
2
2
.
4
7
M
]
REA
R
D
D
P
E
L
E
V
A
T
I
O
N
78.17
'
[
2
3
.
8
3
M
]
FRO
N
T
D
D
P
E
L
E
V
A
T
I
O
N
FIRE DEPT. CONNECTION
FIRE DEPT
ANNUNCIATOR
PANEL
[1180.3 SQF]
[1656.2 SQF]
[1122.3 SQF]
[1104.9 SQF]
[1992.1 SQF]
RESIDENTIAL, COMMERCIAL, & VISITOR PARKING
21 STALLS
5'-
0
"
[1
.
5
m
]
6'-5
3
/
4
"
[2.
0
m
]
6'
-
1
0
1
/
4
"
[2
.
1
m
]
14
'
-
1
0
"
[4
.
5
M
]
COMMERCIAL SERVICE CORRIDOR
EXIT FROM RES ABOVE
EXIT FROM U/G PK
3'
-
8
"
[1
.
1
m
]
UP
DN
UP
25'
[7.6M]
DN
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
24
'
-
3
3
/
8
"
[7
.
4
m
]
Ma
n
e
u
v
e
r
i
n
g
A
i
s
l
e
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
1'-0"
[0.3 m]
VISITOR VISITOR VISITOR VISITOR VISITORVISITORVISITOR
5'-9"
[1.7M]
113'-2"
[34.5M]
1'-0"
[0.3 m]
COMMERCIALCOMMERCIALCOMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIALCOMMERCIALCOMMERCIAL
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
8'-2"
[2.5 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
5'-0"
[1.5 m]
2'-1"
[0.6 m]
8'-2"
[2.5 m]
3'-8"
[1.1 m]
8'-2"
[2.5 m]
1'-0"
[0.3 m]
13'-2 5/8"
[4.0 m]
18
'
-
0
"
[5
.
5
m
]
COMMERCIAL
SERVICES
RESIDENTIAL LOBBY
PARKING
LANDSCAPE
CIRCULATION
SCALE 1:100 ( 24x36 Format )
GROUND FLOOR
GROUND FLOOR
1:100
A1.3
N
22323, 22335, & 22345
CALLAGHAN AVENUE
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
1 Issued for RezoningMar. 5, 2020
2 Issued for DPJul 10th, 2020
NOTE: REFER TO LANDSCAPE DRAWINGS FOR LANDSCAPE
2 BEDROOM= 2
2 BEDROOM + DEN= 5
3 BEDROOM + DEN= 1
1 BEDROOM + DEN= 5
1 BEDROOM= 2
16 UNITS:
STUDIO= 1
CIRCULATION
13
'
-
1
"
[4
.
0
M
]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
11'-2"
[3.4M]
2
5
'
[7
.
6
M
]
10
'
-
7
"
[3
.
2
M
]
2
5
'
-
5
"
[7
.
7
M
]
1
1
'
[3
.
4
M
]
2
5
'
[7
.
6
M
]
1
8
'
-
1
0
"
[5
.
7
M
]
9'-
1
0
"
[3
.
0
M
]
14'-10
"
[4.5M
]
14'-10
"
[4.5M
]
EX.E
L
.
7
9
.
9
8
'
(24.
3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
15
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23
.
9
3
M
)
EX.EL
.
7
7
.
1
0
'
(23.5
0
M
)
EX.EL. 82.67'
(2
5
.
2
0
M
)
H
A
N
E
Y
B
Y
P
A
S
S
LANE
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
20'-9
"
[6.3
M
]
LINE OF CANOPY BELOW
LINE OF CANOPY
BELOW
21'
[6.4M]
1'-10"
[0.6M]
1'
-
1
0
"
[0
.
6
M
]
11
'
-
3
"
[3
.
4
M
]
41
'
-
1
1
"
[1
2
.
8
M
]
48
'
-
2
"
[1
4
.
7
M
]
2'
[0
.
6
M
]
39
'
-
1
1
"
[1
2
.
2
M
]
4'
[1
.
2
M
]
9'-
1
"
[2
.
8
M
]
13
'
-
1
"
[4
.
0
M
]
2'
-
3
"
[0
.
7
M
]
6'-2"
[1.9M
]
5'
[1.5M
]
5'
[1
.
5
M
]
13'-10"
[4.2M]
13
'
-
8
"
[4
.
2
M
]
17
'
-
4
"
[5
.
3
M
]
11
'
[3
.
4
M
]
13
'
-
7
"
[4
.
1
M
]
11
'
[3
.
4
M
]
38
'
[1
1
.
6
M
]
16
'
-
6
"
[5
.
0
M
]
7'
[2.1M]
45'-9"
[13.9M]
26
'
-
1
0
"
[8
.
2
M
]
8'
[2
.
4
M
]
22'-7"
[6.9M]
12'-5"
[3.8M]
10'-7"
[3.2M]
11'-3"
[3.4M]
10'-4"
[3.2M]
3
5
'
-
1
1
"
[1
1
.
0
M
]
6'-3"
[1.9M]
10'
[3.1M]
60'-8"
[18.5M]
21'-7"
[6.6M
]
6'-2"
[1.9M
]
15'-5"
[4.7M
]
16'-9"
[5.1M
]
11
'
-
1
1
"
[3
.
6
M
]
17
'
-
3
"
[5
.
3
M
]
13
'
-
6
"
[4
.
1
M
]
9'-10"
[3.0M]
8'-8"
[2.6M]
6'
[1.8M]
10'-1"
[3.1M]
MASTER
BEDROOM
MASTER
BEDROOM
MASTER
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCBALCBALC
BALC
BALC
BALC
BALC
BALC
BALC BALC BALC
BALC
BALC
BALC
LIVING
LIVING
LIVING
DINING
2082 BD+D
1,186 sf
2131 BD+D
953 sf
203 2 BD+D
1,254 sf2061 BD+D
788 sf
2073 BD+D
1,165 sf
LIVING
DINING
BEDROOM
DINING
MASTER
BEDROOM
200 2 BD
972sf
201 1BD+D
712 sf
2021 BD+D
738 sf
212 STUDIO
435 sf
2152 BD+D
1,052 sf
DEN
MASTER
BEDROOM
DEN
LIVING
DINING
LIVING
DINING
MASTER
BEDROOM
BEDROOMFLEX
204 2 BD+D
1,226 sf
2052 BD+D
1,216 sf
BEDROOM
DINING
2141 BD+D
843 sf
MASTER
BEDROOM
FLEX
MASTER
BEDROOM
BEDROOM
LIVING
BEDROOM
DINING
FLEX
BEDROOM
DINING
DEN
DEN
DINING
MASTER
BEDROOM
BEDROOM
LIVING
DINING
DEN
MASTER
BEDROOM
LIVING
LIVING
MASTER
BEDROOM
DINING
MASTER
BEDROOM
LIVING
DEN
DINING
FLEX
209 1 BD
716 sf
210 2 BD
1,018 sf
211 1 BD
722 sf
19
'
-
7
"
[6
.
0
M
]
15
'
-
5
"
[4
.
7
M
]
DN
UP
DN
UP
MASTER
BEDROOM
DEN
LIVING
DINING
BALC
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SCALE 1:100 ( 24x36 Format )
TYPICAL (2ND-4TH) FLOOR PLAN
TYPICAL
(2ND-4TH) FLOOR PLAN
1:100
A1.4
N
2 BEDROOM= 3
2 BEDROOM + DEN= 4
3 BEDROOM + DEN= 1
1 BEDROOM + DEN= 5
1 BEDROOM= 2
16 UNITS:
STUDIO= 1
CIRCULATION
13
'
-
1
"
[4
.
0
M
]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
11'-2"
[3.4M]
2
5
'
[7
.
6
M
]
1
0
'
-
7
"
[3
.
2
M
]
2
5
'
-
5
"
[7
.
7
M
]
1
1
'
[3
.
4
M
]
2
5
'
[7
.
6
M
]
1
8
'
-
1
0
"
[5
.
7
M
]
9'-
1
0
"
[3
.
0
M
]
14'-10
"
[4.5M
]
14'-10
"
[4.5M
]
EX.E
L
.
7
9
.
9
8
'
(24.3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
15
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23.9
3
M
)
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
EX.EL. 82.67'
(2
5
.
2
0
M
)
H
A
N
E
Y
B
Y
P
A
S
S
LANE
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
20'-9
"
[6.3
M
]
LINE OF CANOPY BELOW
LINE OF CANOPY
BELOW
21'
[6.4M]
1'-10"
[0.6M]
1'
-
1
0
"
[0
.
6
M
]
11
'
-
3
"
[3
.
4
M
]
41
'
-
1
1
"
[1
2
.
8
M
]
48
'
-
2
"
[1
4
.
7
M
]
2'
[0
.
6
M
]
39
'
-
1
1
"
[1
2
.
2
M
]
4'
[1
.
2
M
]
9'-
1
"
[2
.
8
M
]
13
'
-
1
"
[4
.
0
M
]
2'
-
3
"
[0
.
7
M
]
6'-2"
[1.9M
]
5'
[1.5M
]
5'
[1
.
5
M
]
13'-10"
[4.2M]
13
'
-
8
"
[4
.
2
M
]
17
'
-
4
"
[5
.
3
M
]
11
'
[3
.
4
M
]
13
'
-
7
"
[4
.
1
M
]
11
'
[3
.
4
M
]
38
'
[1
1
.
6
M
]
16
'
-
6
"
[5
.
0
M
]
7'
[2.1M]
40'-9"
[12.4M]
26
'
-
1
0
"
[8
.
2
M
]
8'
[2
.
4
M
]
22'-7"
[6.9M]
12'-5"
[3.8M]
10'-7"
[3.2M]
11'-3"
[3.4M]
10'-4"
[3.2M]
3
5
'
-
1
1
"
[1
1
.
0
M
]
6'
[1.8M]
10'-2"
[3.1M]
60'-9"
[18.5M]
21'-7"
[6.6M
]
6'-2"
[1.9M
]
15'-5"
[4.7M
]
16'-9"
[5.1M
]
11
'
-
1
1
"
[3
.
6
M
]
17
'
-
3
"
[5
.
3
M
]
13
'
-
6
"
[4
.
1
M
]
9'-10"
[3.0M]
8'-8"
[2.6M]
6'
[1.8M]
10'-1"
[3.1M]
MASTER
BEDROOM
MASTER
BEDROOM
MASTER
BEDROOM
BEDROOM
BEDROOM
BEDROOM
BALCBALCBALC
BALC
BALC
BALC
BALC
BALC
BALC BALC BALC
BALC
BALC
LIVING
LIVING
LIVING
DINING
DINING
508 2 BD+D
1,187 sf
5131 BD+D
953 sf
503 2 BD
1,020 sf
5061 BD+D
788 sf
5073 BD+D
1,165 sf
LIVING
DINING
BEDROOM
DINING
MASTER
BEDROOM
500 2 BD
501 1BD+D
712 sf
5021 BD+D
738 sf
512 STUDIO
435 sf
5152 BD+D
1,053 sf
DEN
MASTER
BEDROOM
DEN
LIVING
DINING
504 2 BD+D
1,217 sf
5052 BD+D
1,216 sf
BEDROOM
DINING
514 1 BD+D
843 sf
MASTER
BEDROOM
FLEX
MASTER
BEDROOM
BEDROOM
LIVING
BEDROOM
DINING
FLEX
BEDROOM
DINING
DEN
DEN
DINING
MASTER
BEDROOM
BEDROOM
LIVING
DINING
DEN
MASTER
BEDROOM
LIVING
LIVING
MASTER
BEDROOM
DINING
MASTER
BEDROOM
LIVING
DEN
DINING
FLEX
509 1 BD
717 sf
510 2 BD
1,018 sf
511 1 BD
723 sf
19
'
-
7
"
[6
.
0
M
]
15
'
-
5
"
[4.
7
M
]
DN
UP
DN
UP
DECK
MASTER
BEDROOM
DEN
LIVING
DINING
200 2 BD
972sf
BALC
7'
[2.1M]
2'
[0.6M]
LIVING
DINING
MASTER
BEDROOM
BEDROOM
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SCALE 1:100 ( 24x36 Format )
5TH FLOOR PLAN
5TH FLOOR PLAN
1:100
A1.5
N
EX.E
L
.
7
9
.
9
8
'
(24.
3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
15
1
'
-
6
"
[4
6
.
2
M
]
EX.E
L
.
7
8
.
5
1
'
(23.9
3
M
)
EX.EL.
7
7
.
1
0
'
(23.5
0
M
)
EX.EL. 82.67'
(25
.
2
0
M
)
H
A
N
E
Y
B
Y
P
A
S
S
LANE
EX.EL
.
7
7
.
1
0
'
(23.5
0
M
)
20'-
9
"
[6.3
M
]
D.W.
D.
W
.
600 2 BD+D
1,231 sf
602 3 BD
1,632 sf
603 3 BD
1,533 sf
604 2 BD
1,074 sf
605 3 BD
1,597 sf
MASTER
BEDROOM
MASTER
BEDROOM
MASTER
BEDROOM
DECK DECKDECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
BEDROOMBEDROOMBEDROOM
BEDROOM
BEDROOM
BEDROOM
LIVINGLIVING
LIVING
LIVING
DINING
DINING
DINING
DINING
MASTER
BEDROOM
LIVING
D.W.
DINING
BEDROOM
D
W
D
W
D.W.
BEDROOM BEDROOM
DINING
LIVING
BEDROOM
D.W.
LIVINGDINING
601 1 BD
572 sf
BEDROOM
LIVING
DINING
DEN
609 2 BD
1015 sf
MASTER
BEDROOM
LIVING
FLEX
DINING
6081 BD+D
765 sf
BEDROOM
DINING
LIVING
BEDROOM
D.W.
BEDROOM
DEN
606 2 BD
986 sf
6071 BD+D
877 sf
BEDROOM
D.W.
DN
DN
D.W.
13
'
-
1
"
[4
.
0
M
]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
11'
[3.4M]
25'
[7.6M]
2
5
'
[7
.
6
M
]
1
0
'
-
7
"
[3
.
2
M
]
25
'
-
5
"
[7
.
7
M
]
11
'
[3
.
4
M
]
2
5
'
[7
.
6
M
]
1
8
'
-
1
0
"
[5
.
7
M
]
9'-
1
0
"
[3
.
0
M
]
14'-10
"
[4.5M
]
14'-10
"
[4.5M
]
26'-2"
[8.0M]
13
'
-
1
"
[4
.
0
M
]
41
'
-
1
1
"
[1
2
.
8
M
]
48
'
-
2
"
[1
4
.
7
M
]
5'
[1.5M
]
5'
[1
.
5
M
]
13
'
-
8
"
[4
.
2
M
]
49
'
-
1
"
[1
5
.
0
M
]
38
'
[1
1
.
6
M
]
14
'
-
8
"
[4
.
5
M
]
2'-2"
[0.7M]
48'-9"
[14.9M]
28
'
-
1
0
"
[8
.
8
M
]
67'-2"
[20.5M]
3
5
'
-
1
1
"
[1
1
.
0
M
]
76'-11"
[23.5M]
21'-7"
[6.6M
]
6'-10"
[2.1M
]
16'-9"
[5.1M
]
17
'
-
3
"
[5
.
3
M
]
17
'
-
4
"
[5
.
3
M
]
12'-8"
[3.9M]
16'-1"
[4.9M]
15
'
-
8
"
[4
.
8
M
]
13'-10"
[4.2M]
6'-
1
"
[1
.
8
M
]
14
'
-
1
"
[4
.
3
M
]
2 BEDROOM= 3
2 BEDROOM +DEN= 1
3 BEDROOM= 3
1 BEDROOM+DEN= 2
1 BEDROOM= 1
10 UNITS:
STUDIO= 0
CIRCULATION
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
PENTHOUSE - 6TH FLOOR PLAN
PENTHOUSE
6TH FLOOR PLAN
1:100
A1.6
N
SCALE 1: 100 ( 24x36 Format )
UP
DN
DN
16
M
R
A
M
P
@
5
%
DN
21'
[6.4M]
11'-2"
[3.4M]
97'
[29.6M]
13'-10"
[4.2M]
2
3
'
-
1
1
"
[7
.
3
M
]
76'-11"
[23.5M]
21'-6"
[6.5M]
67'-2"
[20.5M]
48'-9"
[14.9M]
14
'
-
8
"
[4
.
5
M
]
38
'
[1
1
.
6
M
]
52
'
-
1
1
"
[1
6
.
1
M
]
2
8
'
R
A
M
P
@
5
%
D
N
EL. 79.00'
(24.10M)
H
A
N
D
I
C
A
P
A
C
C
E
S
S
13
'
-
1
"
[4
.
0
M
]
1
1
0
'
-
8
"
[3
3
.
7
M
]
EL. 77
.
8
3
'
(23.7
2
M
)
EL. 77
.
8
3
'
(23.7
2
M
)
EL. 80.50'
(24.53M)
EL. 77
.
0
0
'
(23.4
7
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
EL. 80
.
5
0
'
(24.5
3
M
)
14'-9"
[4.5M
]
9'-10"
[3.0M]
6'
[1.8M]
5'-10"
[1.8M]
9'
-
1
0
"
[3
.
0
M
]
2'-
6
"
[0
.
8
M
]
7'-6"
[2.3M
]
7'-
1
0
"
[2
.
4
M
]
18
'
[5
.
5
M
]
16
'
-
9
"
[5
.
1
M
]
15
'
-
2
"
[4
.
6
M
]
22'-3"
[6.8M
]
4'
[1
.
2
M
]
13
'
-
2
"
[4
.
0
M
]
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
TO RESIDENTIAL
PARKING U/G
TO COMMERCIAL
VISITOR /PARKING
EX.E
L
.
7
9
.
9
8
'
(24.3
8
M
)
C
U
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
R
O
A
D
D
E
D
I
C
A
T
I
O
N
P
R
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
PR
O
P
E
R
T
Y
L
I
N
E
B
3.1
B
3.1
A
3.1
A
3.1
155'-6"
[47.4M]
7'-5"
[2.3M
]
13
2
'
-
3
"
[4
0
.
3
M
]
264'-3"
[80.5M]
15
1
'
-
6
"
[4
6
.
2
M
]
EX.EL
.
7
8
.
5
1
'
(23.9
3
M
)
EX.EL
.
7
7
.
1
0
'
(23.5
0
M
)
EX.EL. 82.67'
(25.20M)
H
A
N
E
Y
B
Y
P
A
S
S
LANE
EX.EL
.
7
7
.
1
0
'
(23.5
0
M
)
20'-9
"
[6.3
M
]
EL. 80.50'(24.53M)
13
'
-
1
"
[4
.
0
M
]
7.5' R
A
M
P
@
1
0
%
DN
EL. 79.73'
(24.30M)
TOP. 1
5
2
.
5
0
'
(46.4
8
M
)
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
TOP.
1
5
2
.
5
0
'
(46.4
8
M
)
TOP. 1
5
2
.
5
0
'
(46.4
8
M
)
SURFACE PARKING BELOW
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
ROOF PLAN
ROOF PLAN
1:100
A1.7
N
SCALE 1:100 ( 24x36 Format )
P.
L
.
P.
L
.
P.
L
.
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
9
12 23
3
4
6 6
7
8
10
10121314 1516
5
10 5
EL.77
.
8
3
'
(23.
7
2
)
M
EL.77
.
5
9
'
(23.
6
5
)
M
EL.7
7
.
0
0
'
(23.4
7
)
M
EL.77
.
8
3
'
(23.
7
2
)
M
EL.79
.
0
0
'
(24.
1
0
)
M
EL.8
0
.
5
0
'
(24.5
4
)
M
P.
L
.
P.
L
.
P.
L
.
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
1 23
3
4
6
7
9101213
5 11
6 8141516
5
EL.77
.
8
3
'
(23.7
2
)
M
EL.7
7
.
5
9
'
(23.6
5
)
M
EL.77
.
0
0
'
(23.
4
7
)
M
EL.7
7
.
8
3
'
(23.7
2
)
M
EL.7
9
.
0
0
'
(24.1
0
)
M
EL.80
.
5
0
'
(24.5
4
)
M
EXTERIOR HIGH DENSITY FIBER CEMENT BOARD
COLOUR: DARK GREY
FINISH SCHEDULE
SIDING. HARIDIE OR SIMILAR
COLOUR: HEARTH GRAY
VINYL DOUBLE GLAZED THERMALLY BROKEN WINDOWS
COLOUR: CHARCOAL W/ CLEAR GLASS
FASCIA METAL PANEL VICWEST
COLOUR: CHARCOAL
LIGHT FIXTURE
GLASS DOUBLE DOOR
ALUMINUM STOREFRONT
WINDOW COLOUR: SILVER
BRICK MISSION FINISH- MUTUAL MATERIALS
COLOUR:BURGUNDY
METAL CANOPY WITH GLASS TOP
COLOUR: CHARCOAL
ARCHITECTURAL FINISH CONCRETE
COLOUR: G.P SHOAL CL 3234D (OR SIMILAR)
PREFINISHED ALUMINUM LOUVERS
COLOUR: TO MATCH STOREFRONT FRAMES
SPANDREL PANEL
COLOUR: CHARCOAL
SIGNAGE
ALUMINUM WINDOW WALL
COLOUR: CHARCOAL
PREFINISHED METAL SOFFIT- LUX OR SIMILAR
COLOUR: LIGHT ASH
ALUMINIUM GUARDRAIL C/W CLEAR GLASS WITH
TRANSLUCENT BASE , COLOUR: CHARCOAL
7
2
4
8
3
5
10
12
1
13
9
16
14
15
11
6
SOUTHWEST ELEVATION - HANEY BY-PASS
SCALE 1:200
SOUTH ELEVATION - CALLAGHAN
SCALE 1:200
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SOUTH & SOUTHWEST
ELEVATIONS
1:200
A2.1SCALE 1:200 ( 24x36 Format )
SOUTH & SOUTHWEST ELEVATIONS
P.
L
.
P.
L
.
124
6
75
8
11
5
3
10
15
P.
L
.
EL.73
.
9
2
'
(24.3
8
)
M
80.50
'
(24.5
3
)
MEL.73
.
9
2
'
(24.3
8
)
MEL.80
.
5
0
'
(24.5
3
)
M
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
P.
L
.
P.
L
.
2 4
3
5
117
6
5 11023
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
102
2
EL.7
8
.
5
1
(23.
9
3
)
M
EL.8
2
.
6
7
'
(25.
2
0
)
M
EXTERIOR HIGH DENSITY FIBER CEMENT BOARD
COLOUR: DARK GREY
FINISH SCHEDULE
SIDING. HARIDIE OR SIMILAR
COLOUR: HEARTH GRAY
VINYL DOUBLE GLAZED THERMALLY BROKEN WINDOWS
COLOUR: CHARCOAL W/ CLEAR GLASS
FASCIA METAL PANEL VICWEST
COLOUR: CHARCOAL
LIGHT FIXTURE
GLASS DOUBLE DOOR
ALUMINUM STOREFRONT
WINDOW COLOUR: SILVER
BRICK MISSION FINISH- MUTUAL MATERIALS
COLOUR:BURGUNDY
METAL CANOPY WITH GLASS TOP
COLOUR: CHARCOAL
ARCHITECTURAL FINISH CONCRETE
COLOUR: G.P SHOAL CL 3234D (OR SIMILAR)
PREFINISHED ALUMINUM LOUVERS
COLOUR: TO MATCH STOREFRONT FRAMES
SPANDREL PANEL
COLOUR: CHARCOAL
SIGNAGE
ALUMINUM WINDOW WALL
COLOUR: CHARCOAL
PREFINISHED METAL SOFFIT- LUX OR SIMILAR
COLOUR: LIGHT ASH
ALUMINIUM GUARDRAIL C/W CLEAR GLASS WITH
TRANSLUCENT BASE , COLOUR: CHARCOAL
7
2
4
8
3
5
10
12
1
13
9
16
14
15
11
6
EAST ELEVATION
SCALE 1:200
NORTH ELEVATION - LANE
SCALE 1:200
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
NORTH & EAST
ELEVATIONS
1:200
A2.2SCALE 1:200 ( 24x36 Format )
NORTH & EAST ELEVATIONS
P.
L
.
P.
L
.
P.
L
.
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:63.60'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:77.46' 23.61M
DDP FRONT ELEVATION
EL:129.95' 39.61M
DDP FRONT ELEVATION +16M
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
CALLAGHAN AVENUE
STREETSCAPE
1:250
A2.3SCALE 1:250 ( 24x36 Format )
STREETSCAPE - CALAGHAN AVENUE
HANEY
BY-PASS
PROPOSED STREETSCAPE - CALLAGHAN AVE.
SCALE 1:250
224
STREETPROPOSED DEVELOPMENT SITE - 22323, 22335 & 22345 CALLAGHAN AVE.22365 CALLAGHAN 11641 224th ST22375 CALLAGHAN 22381 CALLAGHAN
HANEY BY-PASS CALLAGHAN AVE
HANEY
BY-PASS
EXISTING STREETSCAPE - CALLAGHAN AVE.
SCALE 1:250
224
STREETPROPOSED DEVELOPMENT SITE - 22323, 22335 & 22345 CALLAGHAN AVE.22365 CALLAGHAN 11641 224th ST22375 CALLAGHAN 22381 CALLAGHAN
HANEY BY-PASS CALLAGHAN AVE
2'-6"
[0.8M]
10'
[3.0M]
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
COMMERCIAL
SERVICES
RESIDENTIAL
PARKING
CIRCULATION
CU
R
R
E
N
T
P
.
L
.
ROAD DEDICATION
PR
O
P
O
S
E
D
P
.
L
.
9'-10"
[3.0M]
PR
O
P
E
R
T
Y
L
I
N
E
24.53M
EL.80.6'T.O.RAMP
6'
[1.8M]
HANEY
BY-PASS
5'
2'
11
'
3'
BU
I
L
D
I
N
G
H
E
I
G
H
T
=
7
4
'
-
4
"
15
'
EL:80.50' 24.54M
GROUND FLOOR
10
'
12
'
5'
EL:68.50'
PARKING
12
'
EL:95.50'
L2 - RESIDENTIAL
EL:135.50'
L6 - RESIDENTIAL
EL:147.50'
U/S ROOF
EL:152.50'
T.O. ROOF PARAPET
EL:157.50'
T.O.P.(ELEV. PENTHOUSE)
EL:125.50'
L5 - RESIDENTIAL
EL:115.50'
L4 - RESIDENTIAL
EL:105.50'
L3 - RESIDENTIAL
10
'
10
'
10
'
5'
EL:78.17' [23.83M]
DDP FRONT ELEVATION
PR
O
P
E
R
T
Y
L
I
N
E
PR
O
P
E
R
T
Y
L
I
N
E
13'-1"
[4.0M]
CALLAGHAN AVE.LANE
9'-10"
[3.0M]
5'
2'
11
'
3'
COMMERCIAL
SERVICES
RESIDENTIAL
PARKING
CIRCULATION
72
'
-
3
"
[2
2
.
0
M
]
EL. 24.47m [80.28']
REAR DDP ELEVATION
SITE SECTION B
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SECTION A-A & B-B
1:200
A3.1SCALE 1:200 ( 24x36 Format )
SITE SECTION A
SCALE 1:200 ( 24x36 Format )
A3.2
A
D
A3.2
B
A3.2
A3.2
C
CALLAGHAN AVENUE
H
A
N
E
Y
BY
-
P
A
S
S
LANE
UP
DN
DN
16M
R
A
M
P
@
5
%
DN
21'[6.4M]
11'-2"
[3.4M]
97'
[29.6M]
13'-10"
[4.2M]
23'-
1
1
"
[7.
3
M
]
76'-11"[23.5M]21'-6"[6.5M]67'-2"[20.5M]48'-9"[14.9M]
14'-
8
"
[4.5
M
]
38'
[11
.
6
M
]
52'
-
1
1
"
[16
.
1
M
]
28'
R
A
M
P
@
5
%
DN
EL. 79.00'(24.10M)
CALLAGHAN PARK
HA
N
D
I
C
A
P
A
C
C
E
S
S
13'-
1
"
[4.
0
M
]
110
'
-
8
"
[33.
7
M
]
EL. 77.8
3
'
(23.72
M
)EL. 77.8
3
'
(23.72
M
)
EL. 80.50'
(24.53M)
EL. 77.0
0
'
(23.47M
)
EL. 80.5
0
'
(24.53
M
)
EL. 80
.
5
0
'
(24.53
M
)
EL. 80.
5
0
'
(24.53M
)
EL. 80
.
5
0
'
(24.53
M
)
14'-9"
[4.5M]
9'-10"
[3.0M]
6'
[1.8M]
5'-10"
[1.8M]
9'-1
0
"
[3.0
M
]
2'-6
"
[0.8
M
]
7'-6"
[2.3M]
7'-1
0
"
[2.4
M
]
18'
[5.5
M
]
16'-
9
"
[5.
1
M
]
15'-
2
"
[4.
6
M
]
22'-3"
[6.8M]
4'
[1.
2
M
]
13'-
2
"
[4.
0
M
]
TOP. 15
2
.
5
0
'
(46.48
M
)
TO RESIDENTIAL PARKING U/G TO COMMERCIAL VISITOR /PARKING
EL. 80.50'(24.53M)
13'-1
"
[4.0M
]
7.5' RA
M
P
@
1
0
%
DN
EL. 79.73'(24.30M)
TOP. 15
2
.
5
0
'
(46.48
M
)
TOP. 15
2
.
5
0
'
(46.48
M
)
TOP. 15
2
.
5
0
'
(46.48M
)
TOP. 1
5
2
.
5
0
'
(46.48M
)
SURFACE PARKING BELOW
EL. 68.50'
EL.19.38M
PARKING
EL. 80.50'
EL.25.54M
CRU-GROUND FLOOR
EL. 95.50'
EL.29.10M
L2-RESIDENTIAL
EL. 105.50'
EL.32.15M
L3-RESIDENTIAL
EL. 115.50'
EL.35.20M
L4-RESIDENTIAL
EL. 125.50'
EL.38.25M
L5-RESIDENTIAL
EL. 135.50'
EL.41.30M
L6-RESIDENTIAL
EL. 147.50'
EL.44.95M
U/S ROOF
EL. 152.50'
EL.46.48M
CANOPY
EL. 7
9
.
0
0
'
EL.2
4
.
0
7
M
RAMP
PR
O
P
O
S
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
ROAD DEDICATION
16'-3 1/4"
[4.94M]
12
'
-
0
"
[3
.
6
9
M
]
15
'
-
0
"
[4
.
5
6
M
]
10
'
-
0
"
[3
.
0
6
M
]
HANEY
BYPASS
CU
R
R
E
N
T
P
R
O
P
E
R
T
Y
L
I
N
E
EL. 7
8
.
5
1
'
EL.2
3
.
9
3
M
2'-
6
"
[0
.
7
5
M
]
8'-
0
"
[2
.
4
4
M
]
EL. 68.50'
EL.19.38M
PARKING
EL. 75.7
6
'
EL.23.0
9
M
EL. 80.50'
EL.25.54M
CRU-GROUND FLOOR
EL. 95.50'
EL.29.10M
L2-RESIDENTIAL
EL. 105.50'
EL.32.15M
L3-RESIDENTIAL
EL. 115.50'
EL.35.20M
L4-RESIDENTIAL
EL. 125.50'
EL.38.25M
L5-RESIDENTIAL
EL. 135.50'
EL.41.30M
L6-RESIDENTIAL
EL. 147.50'
EL.44.95M
U/S ROOF
EL. 152.50'
EL.46.48M
T.O. ROOF PARAPET
LANDSCAPE SIDEWALK
PR
O
P
E
R
T
Y
L
I
N
E
5'-11"
[1.81M]
21'-11 1/4"
[6.69M]
CANOPY
CALLAGHAN
AVENUE
L6-RESIDENTIAL
9'-
2
"
[2
.
8
1
M
]
2'-
6
"
[0
.
7
5
M
]
EL. 68.50'
EL.19.38M
EL. 80.50'
EL.25.54M
EL. 95.50'
EL.29.10M
EL. 105.50'
EL.32.15M
EL. 115.50'
EL.35.20M
EL. 125.50'
EL.38.25M
EL. 135.50'
EL.41.30M
EL. 147.50'
EL.44.95M
EL. 152.50'
EL.46.48M
PR
O
P
E
R
T
Y
L
I
N
E
LANE
CRU-GROUND FLOOR
PARKING
L2-RESIDENTIAL
L3-RESIDENTIAL
L4-RESIDENTIAL
L5-RESIDENTIAL
L6-RESIDENTIAL
EL. 80.9
0
'
EL.24.6
6
M
14'-6 1/4"
[4.44M]
WALKWAY
2'-
8
"
[0
.
8
1
M
]
9'-
5
"
[2
.
8
8
M
]
EL. 68.50'
EL.19.38M
EL. 80.50'
EL.25.54M
EL. 95.50'
EL.29.10M
EL. 105.50'
EL.32.15M
EL. 115.50'
EL.35.20M
EL. 125.50'
EL.38.25M
EL. 135.50'
EL.41.30M
EL. 147.50'
EL.44.95M
EL. 152.50'
EL.46.48M
PR
O
P
E
R
T
Y
L
I
N
E
LANE
EL. 83.
2
6
'
EL.25.3
8
M
13'-4"
[4.06M]
WALKWAY
PARKING-U/G
PARKING-GROUND FLOOR
L2-RESIDENTIAL
L3-RESIDENTIAL
L4-RESIDENTIAL
L5-RESIDENTIAL
L6-RESIDENTIAL
L6-RESIDENTIAL
2'-
8
"
[0
.
8
1
M
]
SITE SECTION A
SCALE 1:100
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
SITE SECTIONS
AS NOTED
A3.2
N
SITE SECTION B
SCALE 1:100
SITE SECTION C
SCALE 1:100
SITE SECTION D
SCALE 1:100
SITE PLAN
SCALE 1:500
SCALE: AS NOTED
SITE SECTIONS
1
2
5
6
4
4
2
1
5
3 6
3
22323 ,22335, & 22345
CALLAGHAN AVE.
MAPLE RIDGE, BC
17025
ST
date:description:
revisions
no.:
Copyright Reserved. This drawing is the property of Studioone Architecture Inc.and
may not be produced without the consent of Studioone Architecture Inc.
project title:
drawing title:
project no.:
drawn by:
checked by:
date:
scale:
drawing no.:
Issued for Rezoning1. Mar. 5th, 2020
ar
c
h
i
t
e
c
t
u
r
e
i
n
c
.
studioonearchitecture.ca
240 - 388 West 8th Ave.
Vancouver, B.C. V5Y 3X2
Tel: 604 - 731 - 3966
Fax: 604 - 734 - 1121
Issued for DP2. Jul. 10th, 2020
Issued for ADP3. April. 26th, 2023
3D VIEWS
A4.1SCALE: NTS
RENDERED 3D VIEWS
ALL PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. PROVIDE CERTIFICATION UPON REQUEST.
ALL PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. PROVIDE CERTIFICATION UPON REQUEST.
DN
LOADING
RESIDENTIAL LOBBY
CRU # 1
CRU # 3
CRU # 4
CRU # 5
109.6 SM
153.9 SM
104.3 SM
102.6 SM
RESIDENTIAL REFUSE AND RECYCLING
DN
CRU # 2
185.1 SM
D
N
TO RESIDENTIAL
PARKING U/G
TO COMMERCIAL/
VISITOR PARKING
3 BIKE RACKS
7 BIKE RACKS
9 BIKE RACKS
8 BIKE RACKS
DN
2 x COMM
COMMERCIAL REFUSE
AND RECYCLYING
VEST.
BIKE STORAGE
[1180.3 SQF]
[1656.2 SQF]
[1122.3 SQF]
[1104.9 SQF]
[1992.1 SQF]
RESIDENTIAL, COMMERCIAL, & VISITOR PARKING
21 STALLS
COMMERCIAL SERVICE CORRIDOR
EXIT FROM RES ABOVE
EXIT FROM U/G PK
UP
DN
UP
DN
VISITOR VISITOR VISITOR VISITOR VISITORVISITORVISITOR
COMMERCIALCOMMERCIALCOMMERCIAL COMMERCIAL COMMERCIAL COMMERCIAL COMMERCIALCOMMERCIALCOMMERCIAL
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
D.W.
D.
W
.
600 2 BD+D
1,231 sf
602 3 BD
1,632 sf
603 3 BD
1,533 sf
604 2 BD
1,074 sf
605 3 BD
1,597 sf
MASTER
BEDROOM
MASTER
BEDROOM
MASTER
BEDROOM
DECK DECKDECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
DECK
BEDROOMBEDROOMBEDROOM
BEDROOM
BEDROOM
BEDROOM
LIVINGLIVING
LIVING
LIVING
DINING
DINING
DINING
DINING
MASTER
BEDROOM
LIVING
D.W.
DINING
BEDROOM
D
W
D
W
D.W.
BEDROOM BEDROOM
DINING
LIVING
BEDROOM
D.W.
LIVINGDINING
601 1 BD
572 sf
BEDROOM
LIVING
DINING
DEN
609 2 BD
1015 sf
MASTER
BEDROOM
LIVING
FLEX
DINING
6081 BD+D
765 sf
BEDROOM
DINING
LIVING
BEDROOM
D.W.
BEDROOM
DEN
606 2 BD
986 sf
6071 BD+D877 sf
BEDROOM
D.W.
DN
DN
D.W.
ALL PLANT MATERIAL MUST BE PROVIDED FROM CERTIFIED DISEASE FREE NURSERY. PROVIDE CERTIFICATION UPON REQUEST.
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
PART ONE GENERAL REQUIREMENTS PART THREE SOFT LANDSCAPE DEVELOPMENT PART THREE SOFT LANDSCAPE DEVELOPMENT - CONT PART THREE SOFT LANDSCAPE DEVELOPMENT - CONT
PART TWO SCOPE OF WORK
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
Suite 240 - 388 West 8th Ave. Vancouver BC, V5Y 3X2 Canada T: 604.731.3966
April 27th, 2023
To: The Manager of Development and Environmental Services.
District of Maple Ridge
11995 Haney Place
Maple Ridge, BC, V2X 6A9
Re: Project Coordinated Assessment Strategy Statement (CASS) for proposed residential development
at 22323, 22335, and 22345 Callaghan Avenue, Maple Ridge, BC.
COORDINATION ASSESSMENT STRATEGY STATEMENT (CASS)
1- The proposed development is comprised of three lots at 22323, 22335, and 22345 on Callaghan
Ave. in Town Centre Area, Maple Ridge, with a gross area of 29,874 SQF. A 2.3m road dedication
is required by the Ministry of Transportation along Haney Bypass.
The designated zoning for these parcels is RS-1 (One Family Urban Residential). Rezoning to CRM
is being requested (Commercial/Residential).
The proposed project is a 6-story mixed-use development that provides commercial space for the
neighborhood on the ground floor and residential units above. When three land parcels are
combined, they form a trapezoid corner lot with a total of 56.5 M frontage on Callaghan Ave and
50.3 M frontage on Haney Bypass.
Consultants engaged at this stage of the project are as follows:
· Landscape architect - M2 Landscape Architecture and Arboriculture.
· Civil Engineers - Aplin & Martin Consultants Ltd.
· Land Survey- Terra Pacific Land Surveying Ltd.
· Arborist – M2 Landscape Architecture
2- As project coordinators, we have been provided with reports, plans, and analyses from the
respective consultants mentioned above to complement and assist in the design process and site
analyses. No incompatibilities with regards to recommendations, standards, policies or guidelines
were noted at this stage.
3- At its current stage, the project is designed to comply with federal and provincial regulations and
municipal bylaws, policies and guidelines.
4- A copy of this letter is sent to the consultants listed above and will be included in the submission.
Prepared by:
Studio One Architecture Inc.
Shoghig Tutunjian, Architect AIBC,
Principal
PROJECT:
CLIENT:
APLIN & MARTIN PROJECT No.
OFF-SITE DRAWING INDEX
SITE LOCATION PLAN
20-075 / DX 681
MUNICIPAL PROJECT No.5245-20-2020-065
01 COVER SHEET
02 KEY PLAN & SERVICE CONNECTIONS DETAILS
03
PROPOSED MIXED-USE DEVELOPMENT
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, B.C.
HUANG'S HOLDINGS LTD.
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
ROADWORKS & CROSS SECTIONS LANE
SITE
07
STORM WATER MANAGEMENT PLAN06
EROSION & SEDIMENT CONTROL PLAN STAGE 1 & 2
04 WATERMAIN CALLAGHAN AVE
05 STORM & SANITARY SEWERS LANE
08
STORM WATER MANAGEMENT CALCULATIONS
Landscape
L
a
n
d
s
c
a
p
e
Landscape
L
a
n
d
s
c
a
p
e
Landscape
La
n
d
s
c
a
p
e
20-075-02
PROPOSED MIXED-USE DEVELOPMENT
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0802
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
Landscape Landscape
La
n
d
s
c
a
p
e
20-075-03
PROPOSED MIXED-USE DEVELOPMENT
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
0803
20-075-04
PROPOSED MIXED-USE DEVELOPMENT
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0804
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
20-075-05
PROPOSED MIXED-USE DEVELOPMENT
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0805
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
Landscape
La
n
d
s
c
a
p
e
Landscape
L
a
n
d
s
c
a
p
e
Landscape
La
n
d
s
c
a
p
e
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0806
20-075-06
PROPOSED MIXED-USE DEVELOPMENT
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
HUANG'S HOLDINGS LTD.
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0807
20-075-07
PROPOSED MIXED-USE DEVELOPMENT
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
DEVELOPER:
PROJECT:
Landscape
L
a
n
d
s
c
a
p
e
Landscape
L
a
n
d
s
c
a
p
e
Landscape
La
n
d
s
c
a
p
e
Landscape
La
n
d
s
c
a
p
e
Landscape
L
a
n
d
s
c
a
p
e
Landscape
La
n
d
s
c
a
p
e
DEVELOPER:
PROJECT:
HUANG'S HOLDINGS LTD.
21778 RIVER ROAD, MAPLE RIDGE, BC V2X 2B7
PH (604) 889-8236
0808
STAGE 2
20-075-08
PROPOSED MIXED-USE DEVELOPMENT
22323, 22335 & 22345 CALLAGHAN AVE
MAPLE RIDGE, BC
3862 W. 14 Avenue, Vancouver, B.C. Canada V6R 2W9
Tel: (604) 817-4695, Fax: (604) 597-9061, Email: dlaird@aplinmartin.com
STAGE 1
Arboricultural Assessment Report
220 – 26 Lorne Mews, New Westminster, British Columbia V3M 3L7 Tel: (604) 553-0044 Email: office@m2la.com
Date of Review: February 26, 2020 Project File No.: 20-005
Date of Report:
March 2, 2020 Project Name: Mixed Development at 22323, 22335 &
22345, Maple Ridge, BC
Weather: Cloudy Arborist: Xudong Bao
ISA Certified Arborist PN-8671A, TRAQ
We completed a review of the site conditions on the date of review and note the following:
Re: Arboricultural Assessment Services at 22323, 22335 & 22345, Maple Ridge, BC
For: Mr. Seiko Huang, C/o: Ruba Margieh; Email: ruba@studioonearchitecture.ca
1.0 Introduction:
A site visit was requested by Seiko Huang to review the quality of existing significant and bylaw protected trees at
the site associated with the proposed development of a mixed-use building. We were provided with a copy of the
topographical survey plan as well as a plan showing the proposed form of development. Only the trees detailed in
this report were assessed. The purpose of this review was to outline the existing conditions of the subject trees,
including health and structure, and to determine suitability for tree retention based on the proposed form of
development. This report will be submitted to meet municipal permitting requirements.
A standardized visual assessment method was used for the on-site tree inventory and analysis. Tree species, size,
and condition were noted for each, as well as any outward signs of structural defects, health deficiencies, and/or
environmental conditions potentially impacting the health or structural integrity of the trees. Trees have been
tagged with a number for inventory and reference purposes. Digital photos were taken for file reference and
report writing purposes. A detailed inspection including aerial inspection, decay mapping, excavation explorations
and root mapping was not performed.
2.0 Scope of Work:
Our scope of work is defined by the owner as follows:
a) Assess bylaw size trees within the site and 5m of property line and of neighbouring properties.
b) Assess the feasibility of retaining trees on the site, on neighboring properties and on city property in
association with the form of development proposed.
c) Provide mitigation/protection comments.
March 2, 2020
22323, 22335 & 22345, Maple Ridge, BC.
M2 File # 20-005 Page 2 of 9
3.0 Observation:
The image above is taken from Google Maps and the subject site is outlined in red.
The property is currently a series of single family house along Callaghan Avenue. Callaghan Park is next to project
site on the east.
Street Trees
A total of 10 trees are associated with this development project.
Environmental, Drainage and Wildlife Comments
There were no observed bird nests and no significant wildlife values noted on the site.
March 2, 2020
22323, 22335 & 22345, Maple Ridge, BC.
M2 File # 20-005 Page 3 of 9
Existing Trees / Vegetation
The existing on-site trees are composed of ornamental conifer and deciduous trees. 8 trees and one cedar hedge
shown on survey along Haney By-Pass have been removed at the time of visit.
Attached Photos:
Photo 1: Tree #109 and 750
March 2, 2020
22323, 22335 & 22345, Maple Ridge, BC.
M2 File # 20-005 Page 4 of 9
Photo 2: Tree #747 Photo 3: Tree #748, 749 and 125
Photo 3: tree #1248 Photo 4: Tree A
March 2, 2020
22323, 22335 & 22345, Maple Ridge, BC.
M2 File # 20-005 Page 5 of 9
Photo 4: Tree B and C
March 2, 2020
22323, 22335 & 22345, Maple Ridge, BC.
M2 File # 20-005 Page 6 of 9
3.1 Recommendation:
The mandate from the client to the Arborist was to review the existing trees on site and 5m from the property line,
for their overall health/ quality and to provide comments in regards to their ongoing suitability for retention.
Our recommendation is to all the onsite trees. According to the site plan, all the onsite trees conflict with proposed
development form.
The client should develop the site and install suitable replacement trees on and off site, as necessary or required.
The purpose of the replacement trees is to re-establish a reasonable level of tree cover. Suitable tree species shall
be selected to obtain optimal growth in the given locations and conditions. Refer to municipal requirements for
replacement tree recommendations and select those that will grow to a mature stature and not outgrow the space
in which they will be planted. This approach will ensure the best long-term solution to the specific urban forestry
requirements of this site.
4.0 Limitations
We attach the following clauses to this document to ensure you are fully aware of what is technically and
professionally realistic in the assessment and preservation of trees.
This Arboricultural field review report is based on site observations on the date noted, only. We ensure that the
opinions expressed are a reasonable and accurate representation of the condition of all trees reviewed. The
assessment was completed based on a visual review only and none of the trees were dissected, cored, probed or
climbed. All trees or groups of trees have the potential to fail. No guarantees are offered or implied by M2
Landscape Architecture or their employees that the trees are safe given all conditions. Trees can be managed, but
they cannot be controlled. To live, work or play near trees is to accept some degree of risk.
The assessment provided was based on preliminary information only.
The opinions expressed in this report are valid for a period of one year only. Any trees retained should be reviewed
on a regular (yearly) basis and tree work required should be done as soon as possible to mitigate any risk.
The information provided in this report is for the exclusive use of our client and may not be reproduced or
distributed without permission of M2 Landscape Architecture.
Please contact the undersigned if you have any questions or concerns regarding this matter.
Yours Truly,
(On behalf of M2 Landscape Architecture and Arboriculture Ltd.)
Xudong Bao
ISA Certified Arborist PN-8671A, TRAQ
M2 Landscape Architecture
M2 Landscape ArchitectureProject #20-005 ARBORIST TREE TABLE 22323, 22335 22345 Callaghan AveMaple Ridge, BC
Tree ID
#Botanical Name Common Name
On
Survey
Y/N
Location:
On, off,
Shared,
City
DBH
(cm)
LCR
(%)
Canopy
(dia.)Condition (Structure, Health, TRAQ rating)Comments Retention
Suitability
Retain/
Remove
Tree
Protection
Zone (TPZ)
109 Acer macrophyllum Big leaf maple Y On 71 -4.8 Multiple stems from 8', included bark observed, natural crown form, one big dead limb, next to existing sidewalk, exposed surface roots, self-corrected leaning south.
Conflict with proposed building m Remove 12.8
750 Acer macrophyllum Big leaf maple Y On 103 -7.5 Multiple stems from 7', shares crown with #109, extensive exposed surface roots observed, heavily ivy infested, many dead limbs on top, poor to moderate condition.
Conflict with proposed building m Remove 18.5
747 Gleditsia triacanthos Honye locust N On 39 -2.1 Multiple stems from 2', self-corrected leaning south, next to existing stair and patio, young, no major defects found, not on survey, location is approximate.
Conflict with proposed building m Remove 7.0
748 Thuja plicata Western redcedar N On 23 85 1.6 Dual stems from 2', natural crown form, young, healthy, no major defects found, part of of cedar group, not on survey, location is approximate.
Conflict with proposed building g Remove 4.1
749 Thuja plicata Western redcedar N On 36 85 1.5 Dual stems from base, natural crown form, young, healthy, no major defects found, part of cedar group, not on survey, location is approximate.
Conflict with proposed building g Remove 6.5
125 Thuja plicata Western redcedar Y On 51 80 1.5 Dual stems from base, natural crown form, young, healthy, no major defects, part of cedar group.Conflict with proposed building g Remove 9.2
1248 Picea sitchensis Sitka spruce Y On 40 75 3.2 Single stem, natural crown form, self-corrected leaning northeast, slightly ivy infested, moderate condition, no major defects found.Conflict with proposed parking m Remove 7.2
A Pinus sylvestris Scots pine N On 28 25 1.8 Single stem, trunk failed at 7', unable to tag due to no access, not on survey, location is approximate Conflict with proposed parking p Remove 5.0
B Prunus avium Wild cherry N On 29 -1.5 Dual stems from base, natural crown form, moderate decay, poor condition, unable to tag due to no access, not on survey, location is approximate.
Conflict with proposed building p Remove 5.2
C Picea pungens Blue spruce N On 25 80 1.0 Single stem, natural crown form, young, healthy, no major defects found, unable to tag due to no access, not on survey, location is approximate.
Conflict with proposed building g Remove 4.5
Page 1 of 1 p=poor; m=moderate; g=good;OS=Off Site; CRZ=Critical Root Zone March 2, 2020
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
ARBORIST
22323, 22335 & 22345
MAPLE RIDGE, BC
Callaghan Avenue
RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL RESIDENTIAL
RESIDENTIAL
VISITOR
RESIDENTIAL
VISITOR
COMMERCIALCOMMERCIALCOMMERCIALCOMMERCIALCOMMERCIALCOMMERCIALCOMMERCIAL
RESIDENTIAL
COMMERCIAL
RESIDENTIAL
VISITOR
CHK'D:
DRAWN:
DESIGN:
SCALE:
DATE:
M2LA PROJECT NUMBER:
DRAWING TITLE:
PROJECT:
DRAWING NUMBER:
REVISION DESCRIPTIONNO.DATE DR.
property of M2 Landscape Architects and may not be
reproduced or used for other projects without their permission.
c Copyright reserved. This drawing and design is the
SEAL:
Tel: 604.553.0044
New Westminster, British Columbia
#220 - 26 Lorne Mews
V3M 3L7
Fax: 604.553.0045
Email: office@m2la.com
ARBORIST
22323, 22335 & 22345
MAPLE RIDGE, BC
Callaghan Avenue
DEVELOPMENT DATA SHEET
Existing /Proposed Zone _____________ Date Prepared __________
Proposed (Complies or
state variance needed)
Required Development Data Minimum Required or
Maximum Allowed
LOT AREA* (in square metres)
Gross Total
Less Road Widening / Truncations
Less Park
Net Total
LOT COVERAGE (in % of net lot area)
Total Site Coverage
SETBACKS (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
SETBACKS – Underground Structures (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
BUILDING HEIGHT (in metres/storeys)
Principal
Accessory
NUMBER OF RESIDENTIAL UNITS
Bachelor
One Bedroom
Two Bedroom
Three Bedroom +
Total
GROSS FLOOR AREA (in square metres)
Residential
Retail Commercial
Office Commercial
Other Commercial (Type _________________)
Institutional
Industrial
TOTAL GROSS FLOOR AREA
* If the development site consists of more than one lot, lot dimensions pertain to the entire site.
Proposed (Complies or
variance needed?)
OTHER – state YES or NO for each. If YES describe
on separate sheet.
Heritage Site Tree Survey/Assessment Provided
Watercourse/Steep Slopes Covenants, Stat ROW & Easements
I hereby certify that all the above information is true and correct. I acknowledge that any error or
omissions are the sole responsibility of the undersigned and not the Development and
Environmental Services Department.
Prepared by: ___________________________ __________________________________
Print Name (Please print form and sign above)
NOTE: To be prepared by an Architect for ADP Submission or by an owner/agent (applicant) for Development
Application.
Required Development Data Minimum Required or
Maximum Allowed
DENSITY
# of units/ha (gross)
# of units/ha (net)
Gross Floor Area
Floor Space Ratio (net)
AMENITY SPACE (area in square metres)
Common Activity Area
Useable Open Space
PARKING (number of spaces)
Residential and Multi-Residential Uses
Multi-Residential Town Centre (Bach Units)
Multi-Residential Town Centre (1 Bdr Units)
Multi-Residential Town Centre (Added Bdr)
Commercial Uses
Educational & Assembly Uses
Institutional Use
Industrial Use
Business Park Uses
Comprehensive
Other
Number of spaces for visitors
TOTAL NUMBER OF PARKING SPACES
Number of total for disabled
Number of total (and %) small cars %
Number of total (and %) tandem spaces %
TOTAL OFF STREET LOADING SPACE(S)
BICYCLE PARKING (number of spaces)
Short Term Bicycle Parking
Long Term Bicycle Parking
Suite 240 - 388 West 8th Ave. Vancouver BC, V5Y 3X2 Canada T: 604.731.3966
TRANSMITTAL
To: Planning
City of Maple Ridge
11995 Haney Place
Maple Ridge, BC V2X 6A9
Phone: 604-463-5221
Email: rtardif@mapleridge.ca
Date: April 26, 2023
Project No.: 17025
Project Name:
22323, 22335, 22345 Callaghan
Avenue, Maple Ridge, BC
Attention:
Mr. Rene Tardiff
For Your Information For Approval
Review & Comments As Requested
Fax - Number of Pages Including This Cover_ _ Via Courier
X Via Email
Dear Rene,
Please find the following documents attached for the May 17th, 2023 ADP meeting submission:
1. 2020-065-RZ-ADP Submission Checklist.
2. 2020-065-RZ-ADP Cover Letter.
3. 2020-065-RZ-ADP-22323 Callaghan Ave-ARCH.
4. 2020-065-RZ-ADP-Development Permit Area Checklist.
5. 2020-065-RZ-ADP Civil & SWMP.
6. 2020-065-RZ-ADP-Landscape Presentation.
7. 2020-065-RZ-ADP-Arborist Report.
Kind Regards,
Studio One Architecture Inc.
Shoghig Tutunjian
Principal
Page 1 of 4
City of Maple Ridge
TO: Advisory Design Panel MEETING DATE: May 17, 2023
FILE NO: 2019-051-DP
SUBJECT: 11405 236 Street
PURPOSE:
An Advisory Design Panel (the “ADP”) submission has been received for the above cited application and
property to permit the construction of 18 townhouse units.
The rezoning application being processed in conjunction with this proposal was given First Reading by
Council on March 10, 2020. This rezoning application is accompanied by an Official Community Plan
(OCP) amendment to adjust the conservation boundary around Cottonwood Creek.
This site is subject to being re-zoned to RM-1 (Townhouse Residential) and a portion of the site is
being redesignated to adjust the conservation boundary and to accommodate the proposal. The
development permit application made to the City is subject to Section 8.7 Multi-Family Development
Permit.
BACKGROUND:
Applicant: RUCHIR DHALL
Legal Description: Lot: 3, Section: 16, Township: 12, Plan: NWP7289
OCP:
Existing: Conservation and Urban Residential
Proposed: Conservation and Urban Residential
Zoning:
Existing: RS-3 (One Family Rural Residential)
Proposed: RM-1 (Townhouse Residential)
Surrounding Uses
North: Use: Multi-Family Residential
Zone: RM-1 (Townhouse Residential)
Designation Urban Residential
South: Use: Multi-Family Residential
Zone: RM-1 (Townhouse Residential)
Designation: Urban Residential
East: Use: Single Family Residential
Zone: CD-1-93 (Amenity Residential District)
Designation: Urban Residential
West: Use: Conservation
Zone: RS-3 (One Family Residential)
Designation: Conservation
Existing Use of Property: Single-Family Residential
Page 2 of 4
Proposed Use of Property: Multi-Family Residential
Site Area: 2 ha (5 acres)
Access: 236 Street
Servicing: Urban Standard
DEVELOPMENT PERMIT AREA:
The development permit application made to the City prompting this submission to the ADP is subject
to the Key Guidelines and the Design Guidelines of a Section 8.7 Multi-Family Development Permit.
Key Guidelines:
The following is a brief description and assessment of the proposal’s compliance with the applicable
Key Development Permit Guidelines:
1. New development into established areas should respect private spaces, and incorporate local
neighbourhood elements in building form, height, architectural features and massing.
2. Transitional development should be used to bridge areas of low and high densities, through means
such as stepped building heights, or low rise ground oriented housing located to the periphery of higher
density developments.
3. Large scale developments should be clustered and given architectural separation to foster a sense
of community, and improve visual attractiveness.
4. Pedestrian circulation should be encouraged with attractive streetscapes attained through
landscaping, architectural details, appropriate lighting and by directing parking underground where
possible or away from public view through screened parking structures or surface parking located to
the rear of the property.
Design Guidelines:
The Design Guidelines and a full explanation of how the project complies with them or the reasons
why they are not applicable are attached in Appendix F to this report.
Page 3 of 4
PLANNING COMMENTS:
1. Proposal:
The applicant is proposing a Multi-Family development consisting of approximately 18
townhouse units. All of the units are designed to have double-car garages, be three storeys
high, with four bedrooms.
2. Context:
The subject property, located at 11405 236 Street, is located on the west side of 236 Street
just south of 114A Avenue, and it is approximately 2 ha (5 acres) in size. The eastern portion of
the property has a developable area that is relatively flat (see Appendix A). The western portion
of the property has some steep slopes, some exceeding 25%, and watercourses that are part of
the Cottonwood Creek system. The geotechnical and environmental assessments will determine
the required setbacks from these features.
3. OCP and Zoning Compliance:
The property is designated Urban Residential and Conservation in the OCP. The proposed RM-1
(Townhouse Residential District) zone for townhouses is consistent with the Major Corridor
Residential development of the Urban Residential land use designation. Although 236 Street is
not identified as a Major Corridor on Figure 4 of the OCP, it is built to a Collector standard, and
therefore townhouse development can be supported, based on Policy 3-18 2), which states the
following:
2) Major Corridor Residential – General Characteristics:
a) Major Corridor Residential is characterized by the following:
i. has frontage on an existing Major Road Corridor as identified on Figure 4
Proposed Major Corridor Network Plan, or has frontage on a road built in whole
or part to a collector, arterial, TransLink Major Road, or Provincial Highway
standard;
An amendment to the OCP will be required to adjust the land use boundaries to establish the
extent of the Conservation boundary.
The current application proposes to rezone the subject property RS-3 (One Family Rural
Residential) to RM-1 (Townhouse Residential District) to permit the construction of
approximately 18 townhouse units. It is anticipated that the development will seek variances
for interior and rear yard setbacks. A Development Variance Permit application will be required
and will be the subject of a future report to Council.
The applicant is seeking a Floor Space Ratio (FSR) of 0.75. The permitted density within the
RM-1 (Townhouse Residential District) zone is 0.6.
Page 4 of 4
CONCLUSION:
The Planning Department requests that the Advisory Design Panel provide comments on the development
proposal.
______________________________________________
Prepared by: Rene Tardif
The following appendices are attached hereto:
Appendix A Subject map
Appendix B Explanatory letter from Architect (and Landscape Architect if applicable)
Appendix C ADP Submission Form
Appendix D ADP Applicant Checklist (signed by Architect)
Appendix E Development Data Sheet (signed by Architect)
Appendix F DP Area Guidelines Checklist
Appendix G Architectural and Landscaping Plans
DATE: Feb 8, 2019FILE: 2019-051-RZ
11405 236 STREET
PLANNING DEPARTMENT
SUBJECT PROPERTY
´
Scale: 1:2,500 BY: PC
Legend
Stream
Ditch Centreline
Edge of Marsh
Indefinite Creek
River Centreline
Lake or Reservoir
Marsh
PROJECT DESCRIPTION:
The proposed project is a 18 unit TownHouse Development that is located in the City of Maple
Ridge with an access from 236 Street from the eastern edge of the site.The subject property is
also located close to Kanaka creek and Kanaka way that leads one to the BC Scenic Highway 7.
This project aims to add these 18 townhouse units to the surrounding residential zone.
The site is flanked by parks along the northern,southern and western boundaries.The eastern
side of the site is predominantly a residential neighbourhood.
A 10 minutes walk and 2 minutes drive brings the residents to the Kanaka way which is one of the
busiest road networks that connects the site to commercial/shopping facilities and schools and also
to the Trans Canada Trail along Kanaka Creek.Within 20 minutes walking distance and 6 minutes
drive,residents have access to British Columbia Highway 7 and Lougheed highway,enabling
faster and easier access to major cities across the province.
The location of the site is ideal for such a multi-family housing project which would be an addition
to the existing residential properties in the neighbourhood,that is swiftly expanding to keep up with
the added demand for housing.The lot is surrounded by a variety of amenities including parks,
educational institutions,and others within walking distances.
ARCHITECTURAL:
The form and character of the buildings was developed to blend with the existing residential units
around the lot,without being overtly distinct and to merge into the fast developing urban fabric.
From this perspective,we have carefully considered the heights of the surrounding residential units
and have made sure that the building heights for the units proposed are consistent.The
development comprises 17 four bedroom units and 1 three bedroom unit.The design for all units
aim to provide family friendly housing,with abundance of yard space,common outdoor amenity
areas,direct natural lighting into all rooms and sufficient storage and parking space.All units also
have a flex space on the third floor that can be used as a den or study.
The entries to the units are marked distinctively and emphasised with a design of distinct portals
that also serve as vertical weather protection for the doors and windows.Buildings 01 and 04 have
similar elevation material finishes whereas Buildings 02 and 03 match in terms of material finishes.
We have chosen to provide material finishes that are complementary to each other.The parking
garage for each unit is designed for two cars and can be accessed by the internal roads for all
units.All units also have some space designated for waste/recycle collection within the parking
garage that can later be taken to the garbage enclosure on-site for collection.
Towards the rear of the site at the West,a dedication is made for development of a park.We have
also provided a 15m setback from the creek running along the western portion of the site.All units
for Building 01 and Building 02 have yard space that overlook the ravine and takes full advantage
of the views.The 1.5m sidewalk along the property line at 236 Street,can also be used by the
residents that will eventually take them to various amenities such as parks,educational institutions,
and others,all within walking distances.Residents and their guests have ample parking facilities as
required by the zoning by-law.
Owing to the richness of the environmental context,the onsite landscape for this project promises
to ensure that the residents have an enhanced outdoor experience.Amenity areas for residents
with plenty of play areas for children are provided towards the north of the site and are safe and
away from noise.Multiple seating opportunities with plenty of shade are provided on-site for the
residents.On the East of the property along 236 Street,planters are proposed so as to not
overpower the form and character of the building and are proposed with ornamental shrubs and
trees to add colour and texture to the building,as well as to be enjoyed by users of the proposed
1.5m sidewalk.Each unit has ample usable open space that is designed with a patio as well as
plenty of planting.
LANDSCAPE:
Owing to the extremely rich environmental and natural setting with a creek and ravine at the west
end,the landscape is being visualised to utilise these features.In order to create definition and
connections for the functional movement activities like the vehicular,bicycle and the pedestrian,
care has been taken to intertwine them with nature to respect the context and the setting.Thereby,
it can be noted that this concept imparts a continuum from the eastern road frontage to the ravine
at the rear edge of the proposal (West).It should be noted that this ownership parcel extends way
beyond the proposed development to the west and we would like the development to have a good
visual connection with this dedicated zone.
We are proposing a palette of distinct paving materials for identification of its usage and to
accentuate the built form edge.The boulevard trees are being proposed to keep a bright feel of the
streets with the potential of adding a dash of fall colour.Further it is an addition to evergreen and
native palette with low maintenance shrubs affording low litter.
The external hedge is proposed to have multiple layers.Regarding privacy of individual units,
Taxus in combination with Spiraea Japonica as well as Sarcococca Ruscifolia is proposed to create
a softer separation.The columnar Thuja hedges lined against the property boundary along the
South and North to afford privacy to the site from neighbouring lots,while adding privacy for
residential patios in the South.The site is populated with a combination of perennials,grasses,and
native plants requiring least maintenance with a dash of colourful shrubs.These are punctuated
with Salix Purpurea NANA'to add a subtle texture with small trees.
As discussed above,the pedestrian access points and their internal movement is lined with
pleasant shrubs and ornamental grasses and perennials for way-finding.The outdoor amenity
space has been designed with a very distinct two zone concept.The intent is to have a Play area
on the North-eastern side and social area on the South Western corner of the property,potentially
located to enjoy the green private setting to the west.The social area which is envisaged to have a
bit of a seating is edged with a combination of ornamental grasses and colour adding shrubs.
SUSTAINIBILITY PRACTICES
Sustainability in buildings is becoming an increasingly important aspect of modern construction.
With concerns about the impact of buildings on the environment,sustainable building practices aim
to reduce the negative effects of construction and operation on natural resources.This involves
considering factors such as energy efficiency,water conservation,use of renewable materials,and
waste reduction.By incorporating sustainable practices into building design and construction,
buildings can be made to operate more efficiently,with less impact on the environment,and
potentially lower operating costs.This project is trying to achieve this through the use of
sustainable materials,green technologies,and efficient design practices.We have also taken into
consideration the building envelope performance,mechanical efficiency and performance,efficient
energy consumption as well as better indoor air quality.Some of the features that we have included
are as follows:
●Vertical solar control elements
●High Performance Envelope
●Use of native vegetation
●Design of units with operable openings
●Parking spots roughed in with EV level 2 charging capabilities
●Optimization of the opening design with a careful balance to achieve natural light and
energy losses.
CPTED:
The residential nature of the project calls for measures that offer safety and security.We have tried
to ensure that there aren't any residual spaces that can be used for unauthorized activity and offer
threats to the security of the development.All the ground level patios are contained and separated
and the other setback areas are planted with low bushes not offering any unwanted gathering
opportunities and (or)risks.
The City
schedule
making y
ADP subm
ADP thro
Applicati
Name of
File num
Address
Current Z
Seeking t
Architect
Submissi
Architect
Landscap
Other Pro
Note.: Th
developm
taken fro
bulletin,
Major
per th
build
Group A (Pa
Group B (Pa
Group C Res
Group D & E
Group F (F1
Adv
of Maple Rid
es for submis
your submiss
mission pack
ough your Fil
ion Informa
Applicant
ber
of site
Zone
to appear be
t Informatio
on will be p
t
pe Architect
ofessional (S
he Architects
ments to the
om AIBC Bull
click here.
Occupancy
he current
ing codes
art 3)
art 3)
sidential
E
: Part 3)
isory Des
dge Advisory
ssion deadlin
sion, contact
kage for you
le Manager w
tion:
_________
_________
_________
_________
efore the AD
on:
resented to
_________
_________
State Name
s are require
e ADP that a
letin 31 Build
Public Assem
Hospital, San
Home for the
Aged
Institutional
Hotel or sim
Commercial
Industrial
sign Pane
y Design Pan
ne dates and
t your File M
ur project. Fo
well in adva
__________
__________
__________
___ Propose
DP on this da
ADP by:
__________
__________
& Role) ____
ed to prepar
re in the Ma
dings Requir
Use
mbly
natorium, or
e
ilar occupancy
el Submis
nel (ADP) me
d for the min
Manager to e
orward your
nce of the d
___________
_____
___________
ed Zone ____
ate ________
___________
___________
__________
re plans and
ajor Occupan
ring the Serv
Type
services
− any o
exce
− any b
exce
− all sc
− any b
capa
− any b
− any b
− any b
− any b
− any b
ssion Req
eets monthly
nimum subm
establish wh
r complete s
deadline date
__________
__________
__________
__________
________
_______
___________
to attend a
ncy categori
vices of an A
es of Building or
s of an architect
one‐storey build
eeding 9 m or gro
building of more
eeding 235 m²; a
chools, any size
building (exclud
acity exceeding 1
building with gro
building contain
building contain
building with gro
building with gro
uest Form
y.Refer to t
mission requ
at constitute
ubmission p
e.
__
__
__
__
__________
nd to presen
es cited in th
Architect. Fo
r Parts of Buildin
t under section 6
Act.
ding with an uns
oss area exceed
e than one store
and
ing veterinary h
12 beds
oss area exceed
ning 5 or more d
ning 11 or more g
oss area exceed
oss area exceed
m
he attached
irements. Be
es a complet
package for t
____
nt all
he Table bel
r the entire
ng requiring the
60 of the Archit
supported span
ing 275 m²;
ey with gross are
ospital) with a
ing 470 m²
welling units
guest rooms
ing 470 m²
ing 470 m²
efore
te
the
ow
e
ects
ea
Ruchir Dhall, Architect AIBC
2019-051-DP
11405 236 Street, Maple Ridge, V2W 1G1
RS-3 RM-1
May 17, 2023
Ruchir Dhall, Architect AIBC
Ruchir Dhall, CSLA
DEVELOPMENT DATA SHEET
Existing /Proposed Zone _____________ Date Prepared __________
Proposed (Complies or
state variance needed)
Required Development Data Minimum Required or
Maximum Allowed
LOT AREA* (in square metres)
Gross Total
Less Road Widening / Truncations
Less Park
Net Total
LOT COVERAGE (in % of net lot area)
Total Site Coverage
SETBACKS (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
SETBACKS – Underground Structures (in metres)
Front
Rear
Side #1 (N,S,E, or W)
Side #2 (N,S,E, or W)
Side #3 (N, S, E or W)
BUILDING HEIGHT (in metres/storeys)
Principal
Accessory
NUMBER OF RESIDENTIAL UNITS
Bachelor
One Bedroom
Two Bedroom
Three Bedroom +
Total
GROSS FLOOR AREA (in square metres)
Residential
Retail Commercial
Office Commercial
Other Commercial (Type _________________)
Institutional
Industrial
TOTAL GROSS FLOOR AREA
* If the development site consists of more than one lot, lot dimensions pertain to the entire site.
Proposed (Complies or
variance needed?)
OTHER – state YES or NO for each. If YES describe
on separate sheet.
Heritage Site Tree Survey/Assessment Provided
Watercourse/Steep Slopes Covenants, Stat ROW & Easements
I hereby certify that all the above information is true and correct. I acknowledge that any error or
omissions are the sole responsibility of the undersigned and not the Development and
Environmental Services Department.
Prepared by: ___________________________ __________________________________
Print Name (Please print form and sign above)
NOTE: To be prepared by an Architect for ADP Submission or by an owner/agent (applicant) for Development
Application.
Required Development Data Minimum Required or
Maximum Allowed
DENSITY
# of units/ha (gross)
# of units/ha (net)
Gross Floor Area
Floor Space Ratio (net)
AMENITY SPACE (area in square metres)
Common Activity Area
Useable Open Space
PARKING (number of spaces)
Residential and Multi-Residential Uses
Multi-Residential Town Centre (Bach Units)
Multi-Residential Town Centre (1 Bdr Units)
Multi-Residential Town Centre (Added Bdr)
Commercial Uses
Educational & Assembly Uses
Institutional Use
Industrial Use
Business Park Uses
Comprehensive
Other
Number of spaces for visitors
TOTAL NUMBER OF PARKING SPACES
Number of total for disabled
Number of total (and %) small cars %
Number of total (and %) tandem spaces %
TOTAL OFF STREET LOADING SPACE(S)
BICYCLE PARKING (number of spaces)
Short Term Bicycle Parking
Long Term Bicycle Parking
Pursuant with Section 8.7 of the Official Community Plan, multi-family developments will be
assessed against the following form and character guidelines.
This checklist is intended to aid in the review of multi-family development permits and is to be
completed by the architect of record for the project. It is noted that the project will also be
reviewed for consistency with the guidelines by the Planning Department staff and the Advisory
Design Panel.
Key Guideline Concepts
Consistent
Yes No
If No, provide
justification for
inconsistency
1. New development into established areas should
respect private spaces, and incorporate local
neighbourhood elements in building form, height,
itectural features and massing. arch
2. Transitional development should be used to bridge
areas of low and high densities, through means such
as stepped building heights, or low rise ground
oriented housing located to the periphery of a higher
density developments.
3. Large scale developments should be clustered and
given architectural separation to foster a sense of
community, and improve visual attractiveness.
4. Pedestrian circulation should be encouraged with
attractive streetscapes attained through landscaping,
architectural details, appropriate lighting and by
directing parking underground where possible or
away from public view through screened parking
structures or surface parking located to the rear of
the property.
Guidelines Consistent
Yes No
If No, provide
justification for
inconsistency
A. Building Design, Massing, and Siting
1. Design and siting of buildings should take advantage
of natural features or views and should enhance
privacy and livability.
2. Residential buildings should front or appear to front
onto public roads through the use of appropriate
treatment of exteriors, through direct pedestrian
access to individual units from the public
street/sidewalk, or through the provision of
pedestrian walkways linked to the street. Street
frontages should be emphasized by incorporating
Multi-Family Development Permit Area Guidelines
- 1 -
differentiated front, side and rear oriented facades,
with a minimum two storey facade on the fronting
street to foster a human scale. Buildings that are
designed with an end wall or unit adjacent to a
public street should design the end unit with the
pedestrian entry facing the street. At significant
intersections, the definition of corners should be
reinforced by buildings that front on both streets and
incorporate corner cuts.
3. Higher density dwellings should be sited adjacent to
major streets in order to minimize access problems
and to provide a transition to lower density uses.
4. Multi-family developments adjacent to lower
density or single detached residential dwellings
should:
a) be consistent in form and massing with the
surrounding area;
b) be sited adjacent to major streets to provide a
transition to lower density uses;
c) concentrate density to the centre of the
development or towards a non-residential
boundary and locate lower density components
adjacent to lower density residential uses;
d) create a transition in building mass and form
towards the setbacks of the adjacent
neighbourhood;
e) minimize access conflicts;
f) be designed to maximize privacy and minimize
views onto adjoining sites, particularly for
portions of the development abutting the side
yards of adjacent single detached residential
uses.
5. Larger buildings, roof forms and building frontages
should include design elements and features to:
a) provide variation in the facades to help reduce
the visual length of individual buildings;
b) have the appearance of a series of smaller
buildings, or as identifiable parts of a larger
concept; and
c) incorporate components that express strong unit
identity and incorporate direct access to grade
for ground-floor units.
6. New multi-family developments should use design
themes, architectural features and elements of the
surrounding neighbourhood by incorporating
common elements such as form, scale, massing and
proportion into the design as a means to reinforce
neighbourhood stability. Examples include:
a) the articulation of facades, using where
appropriate, elements such as porches,
chimneys,
projections, recesses, and balconies;
- 2 -
b) the placement, size, shape and number of doors
and windows;
c) the location and visual appearance of garages
and/or parking facilities;
d) the selection of appropriate and compatible roof
forms; and
e) the design of hard and soft landscaping.
7. The exposed undersides of balconies and porches
that are visible from a street or public walkway
should be covered with exterior finishes to provide
a finished appearance to public view.
8. Developments are encouraged to use the Leadership
in Energy and Environmental Design (LEEDS)
standards in the design of buildings. Techniques
such as rain gardens, vegetated swales, separation of
impervious surfaces, installing below surface
infiltration beds and tree box filters, and redirecting
water from drain pipes into vegetated areas are
encouraged.
9. Variation in individual unit designs is encouraged to
provide visual interest and avoid significant
repetition either within a row of townhouses, or
between adjacent rows of units.
10. Garage doors should not face public streets. Where
front facing garage doors are unavoidable, the
impact of garage doors on the public realm should
be mitigated by:
a) designing residential units with enough width
to include attractive entrances and windows
between garages;
b) recessing garage doors behind the main
building facade;
c) keeping a sufficient width in residential units to
allow the creation of attractive entrances and
fenestration between garages.
d) grouping garage doors in pairs between
adjacent units to allow building entrances and
facades more prominence on the street;
e) providing interior spaces that overlook the
street;
f) separating and orienting unit entrances to the
street;
g) providing individual pedestrian walkways
linked to the street;
h) including design details such as transom
windows or glazing in garage doors;
i) a comprehensive landscape plan that identifies
how the visual impact of garage doors from the
street will be mitigated.
11. Landscaping of rooftops is encouraged where
possible, to provide shared or private outdoor space
- 3 -
for residents and to provide attractive views for
residents and passersby.
B. Vehicle Access, Parking and Circulation
1. Parking and servicing should be located
underground or to the rear of buildings, with access
from lanes wherever possible. Where lane access is
not possible, access should be from streets via
narrow driveways to minimize the impact on
streetscape appearance and disruption to pedestrian
movement.
2. Parking structures should be adequately screened
and architecturally compatible with the rest of the
building. Large surface parking areas should be
divided into smaller sections to avoid a monotonous
appearance with landscaping strips, trees, building
edges, pedestrian pathways, and pavement treatment
to enhance their visual appearance.
3. Developments with large parking areas should
provide a direct pedestrian pathway system through
the parking area to facilitate convenient and safe
pedestrian access between building entrances,
parked cars, and sidewalks of adjoining streets.
Features such as special landscaping with trees and
benches, overhead weather protection and distinct
paving should be incorporated where appropriate.
Pedestrian movement should be designed to avoid
any obstruction by parked vehicles.
4. Shared vehicle access between adjoining sites
should be considered where access for parking at
the rear of the property is limited. Joint or shared
access should also be considered between adjoining
developments to minimize disruption of pedestrian
sidewalks and to maximize landscaping and
permeable surfaces. Integration of driving aisles
and pedestrian walkways between adjacent sites is
also strongly encouraged.
5. Locate parking spaces allocated for people with
disabilities as close as possible to the main entrance
to a building.
6. Crime Prevention through Environmental Design
(CPTED) principles should be incorporated into the
design of all parking facilities with convenient, safe,
identifiable and universally accessible access routes
to building entrances, lobbies or other principal
areas of buildings, and to grade level from any
underground or above ground parking structures.
7. To increase safety, consider using electronic
security devices and monitoring systems as a
- 4 -
supplement to natural surveillance opportunities in
parking structures and parking areas.
8. The amount of asphalt surfaces in parking areas
should be minimized by integrating a variety of
paving materials such as concrete, decorative
pavers, etc. or by using alternate surface treatments.
9. Road grades, streets, lanes, and driveways should
conform to the existing grades as closely as possible
to ensure minimal disruption of slopes and
vegetation. On steep terrain, roads should be
aligned, wherever possible, to run parallel rather
than counter to, natural contours and existing
grades.
C. Landscaping and Open Space
1. Landscaping both within and outside the
development should:
a) provide definition for pedestrian corridors;
b) delineate private and semi private space from
public space;
c) provide adequate screening between private
outdoor spaces;
d) present a pleasing street image;
e) provide suitable buffering between public road
and privacy areas;
f) soften the transition between adjacent land
uses;
g) provide a buffer between residential and non-
residential land uses;
h) create interesting views and focal points into
and out of the site;
i) reinforce design continuity with neighbouring
properties, the scale and massing of buildings,
and the streetscape by providing consistency in
street trees, plant materials, and other
landscaping elements.
2. Landscape drawings for development applications
should include, but are not limited to, the following
information:
a) the location of mature and existing trees to be
retained or removed,
b) the location of all protective tree fencing;
c) a grading plan or cross section indicating
finished grade; and
d) a drainage plan for the site.
3. Street trees will be a required component of all
development. Incorporate deciduous tree species
into streetfront landscaping to define site
boundaries, to enhance public space, and to permit
light penetration in winter.
- 5 -
4. Energy efficiency and conservation should be
considered in the design of landscaped areas and in
the selection of plant material. This can be
accomplished through:
a) using native and/or drought-resistant species;
b) designing the landscaping to moderate the
effect of wind;
c) providing shade in summer;
d) allowing natural drainage to occur throughout
the site;
e) allowing daylight into buildings; and
f) redirecting water from rooftop runoff and
downspouts into vegetated areas or rain barrels
for later irrigation use.
g) Maintain continuous landscaping along
abutting streets and minimize the number of
interruptions such as driveways and parking
entrances. Continue the sidewalk pavement
across driveways and parking entrances.
5. Maintain continuous landscaping along abutting
streets and minimize the number of interruptions
such as driveways and parking entrances. Continue
the sidewalk pavement across driveways and
parking entrances.
6. Create visual landmarks on significant street corners
and at locations of high visibility. Provide
landscaping and consider incorporating features
such as flag poles, banners, visual art, ornamental
trees, fountains, architectural elements, and
landscape structures.
7. Any portion of a building site left vacant for future
development should be landscaped consistent with
the landscape plan for the overall site. The
minimum ground surface treatment should be lawn.
Where possible, the natural state should be retained
for those portions of a property not being
developed.
8. Identify, preserve and incorporate stands of mature
trees into the overall site landscaping design.
Retain unique tree species, significant vegetation,
natural landscape features and nesting areas on a
site wherever possible. To attain this objective,
prior to the design of a project, a detailed survey
prepared by a qualified professional indicating the
location and condition of existing trees and
vegetation on a site should be conducted and
provided to the District as part of the development
application process.
9. Existing vegetation should be enhanced with new
planting wherever construction activity has
destroyed vegetation. Replanting with indigenous
- 6 -
or native species is encouraged.
10. Consider incorporating rain gardens and vegetated
swales into parking lot landscaping to increase the
natural absorption of rainwater runoff from paved
areas into the ground.
11. The height and location of a landscape screen
should ensure that:
a) privacy to adjacent properties is adequately
protected;
b) driving site lines are maintained from adjacent
roads, manoeuvring aisles, parking lots; and
c) the quality of the streetscape and outdoor living
spaces is enhanced.
12. Maximize the amount of landscaped areas and
minimize the amount of impervious paved surfaces
to increase the natural absorption of rainwater on a
site.
D. Universally Accessible Design
1. All non-vehicular routes should be fully accessible.
Sidewalks and pathways should be wide enough for
wheelchair/scooters and should include a tactile
strip for the visually impaired. Curb-cuts and curb
let-downs should be provided in appropriate
locations to facilitate safe, convenient, and direct
access from parking spaces to buildings for people
with disabilities.
2. Building entries should be:
a) clearly addressed with large numbers visible
from the street;
b) directly accessed from the street without stairs;
c) provided with level areas measuring a
minimum of 1.5m x 1.5m (4.9 ft. x 4.9 ft.)
both inside and outside of doorways; and
d) provided with weather protection, exterior
lighting, and power-assisted door openers.
E. Refuse, Recycling and Service Areas
1. Integrate vents, mechanical rooms, mechanical
equipment, and elevator penthouses into the roof
design or screen with materials and finishes
compatible with the overall architectural design.
2. The design of a roof, placement of mechanical units
and satellite dishes, etc. should take into account
views of the roof from adjacent buildings.
3. Garbage containers and recycling bins must be:
a) easily accessible;
- 7 -
b) appropriately sized for the building occupants;
c) contained within roofed/walled enclosures;
d) incorporated into the overall design of the
development; or
e) screened from public view and weatherproof
and animal-resistant within the boundaries of
each site.
4. Service areas should be internalized within the
development. For developments with multiple
buildings, common refuse, recycling and service
areas are to be provided. Storage areas should be
located to be convenient and readily accessible from
most buildings or units on the site. Avoid direct
exposure from public streets and allow for adequate
manoeuvring space for removal vehicles.
5. Enclose or screen all exterior mechanical units or
equipment, including roof top units, equipment, and
satellite dishes within upper floors or structures that
from part of the overall design of a development.
6. Locate building ventilation systems away from
pedestrian areas, residential units, and outdoor
spaces to minimize noise and exhaust in these areas
and locate less sensitive land uses closer to sources
of noise.
7. Buildings should be designed and constructed
maximize sound attenuation:
a) between units;
b) between public roads and units; and
c) between adjacent land uses and units.
F. Signage and Lighting
1. All signage must conform to the Maple Ridge Sign
Bylaw. In the event of a conflict between the Maple
Ridge Sign Bylaw and these guidelines, the latter
shall take precedent.
2. Signage design, materials and message should be
integrated and complement the scale and
architectural detail of the building.
3. Pedestrian level lighting is encouraged along all
pedestrian routes and pedestrian plazas. The
lighting should be pedestrian focused.
4. Lighting should be designed so as to have no direct
source of light visible from the public right-of-way
or adjacent residential land. Care should be taken to
ensure that lighting glare does not pose a nuisance
to adjacent residences, pedestrians, or motorists.
- 8 -
G. Bicycle Parking and Storage
1. Short term and long term bicycle parking facilities
should be considered for all developments. Short
term bicycle parking should be in well-lit locations
and clearly visible from a main building entrance
and/or public roads with bicycle racks made of
sturdy, theft-resistant material that is securely
anchored to the floor or ground. Longer term
bicycle storage areas provided as part of a parking
structure should be located close to elevators and
access points.
Date:____________________________
Architect Name/Company ___________________________________
Municipal File No. _________________________
Plan Description: _______________________________________________
______________________________________________________________
______________________________________________________________
Project No. ________________________________
Signature __________________________________
- 9 -
COORDINATED ASSESSMENT STRATEGY
STATEMENT
ATTN:
The Manager
Development and Environmental Services
DATE:28 April 2023
SUBJECT:CASS LETTER FOR APPLICATION NO.2019-051-DP
The proposed project is a 18 unit TownHouse Development that is located in the City of Maple
Ridge with an access from 236 Street from the eastern edge of the site.The subject property is
also located close to Kanaka creek and Kanaka way that leads one to the BC Scenic Highway 7.
The site is flanked by parks along the northern,southern and western boundaries.The eastern
side of the site is predominantly a residential neighbourhood.
The location of the site is ideal for such a multi-family housing project which would be an addition
to the existing residential properties in the neighbourhood,that is swiftly expanding to keep up with
the added demand for housing.The lot is surrounded by a variety of amenities including parks,
educational institutions,and others within walking distances.
Owing to the extremely rich environmental and natural setting with a creek and ravine at the west
end,the landscape is being visualized to utilize these features.In order to create definition and
connections for the functional movement activities like the vehicular,bicycle and the pedestrian,
care has been taken to intertwine them with nature to respect the context and the setting.Thereby,
it can be noted that this concept imparts a continuum from the eastern road frontage to the ravine
at the rear edge of the proposal (West).It should be noted that this ownership parcel extends way
beyond the proposed development to the west and we would like the development to have a good
visual connection with this dedicated zone.
The Coordinated Team for this project includes the following professional consultants:
1.Architect -Ruchir Dhall,Architect AIBC
Architecture Panel Inc.
2.Landscape Architect -Ruchir Dhall,CSLA
Architecture Panel Inc.
3.Civil Consultants -Dharam Kajal,P.Eng.,M.Eng
Westridge Engineering &Consulting Ltd.
4.Land Surveyor -Sean Costello,BCLS
Cameron Land Surveying Ltd.
5.Arborist -Godde Arboriculture Consulting
6.Geotechnical -Harman Dhillon,P.Eng
Braun Geotechnical Ltd.
7.QEP -Richard Borthwick,M.Sc.,R.P.Bio
Madrone Environmental Services Ltd.
We have reviewed and found the submissions and reports furnished by the consultant team to be
consistent ,conforming and coordinated.
The layout,design and the proposal has been verified by the respective consultants on the team
and found to be meeting or exceeding the federal,provincial and municipal requirements as
required.
end.
Ruchir Dhall,Architect AIBC,CSLA,
Architecture Panel Inc.
STORMWATER MANAGEMENT PLAN LETTER REPORT
Date: April 21, 2023
File: WEL-2018-C694
Atten:
City of Maple Ridge
Building/Plumbing Official
Development Engineering Technologist
City of Maple Ridge
11995 Haney Place
Maple Ridge, B.C., V2X 6A9
Dear Sir:
Re: Project: 20 Units Townhouse at
Location: 11405 – 236 Street, Maple Ridge, BC
This letter is to summarize the objectives of the Stormwater Management Plan for the
proposed development at 11405 – 236 Street in the City of Maple Ridge. Please refer to
the latest Stormwater Management Plan drawing and calculations for reference. See
attached.
Tier A: Capture the runoff from impervious surfaces area during 50% of the MAR storm
event. (36.72mm).
Approximately 35% of the proposed site area is previous landscaping, the total volume of
capture required in Tier A is 164.0 cubic meters and the Total Absorbent Volume
exceeds it which is 232.80 cubic meters.
Tier B: Capture a 1:2-year post-development flow rate from the impervious area and
release it at a controlled rate of a 1:2-year forested flow rate.
Calculations on the Stormwater Management plan show that 131.05 cubic meters of
storage will be detained and released at a rate of 0.3798 L/s to meet the Tier B
WESTRIDGE ENGINEERING &
CONSULTING LTD. SPECIALIZED PROJECTS AND DEVELOPMENTS
Suite #215, 12992 – 76 Avenue, Surrey, V3W 2V6
P : 604.789.9520
www.westridgeengineering.ca
requirements. Given the volumetric requirements from Tire A requirements, this is
feasible for the proposed works.
Tier C: To detain 1:10- year post-development flow and release it at the 1:2 Year pre-
development flow rate.
The highest value of storage required is = 124.81 cubic meters and the detention on the
site provided is 161.56 cubic meters.
Required detention within (TIER A+B+C) in cubic meters = 164 +131.05+124.81 =
419.86 cubic meters.
Provided Detention on-site with (TIER A+B+C) in cubic meters = 232.8 + 28.13 +
161.56 = 422.50 cubic meters
We hope that this meets your needs. Should you require any additional information on
the Stormwater Management Plan, please do not hesitate to contact the undersigned at
(604) 789 –9520.
Yours truly,
Westridge Engineering & Consulting Ltd.
Dharam Kajal, P.Eng., M.Eng.
Permit to Practice: 1001693
L
E
W
PRELIMINARY PLAN
FOR PLANNING ONLY
(NOT FOR CONSTRUCTION)
PRELIMINARY PLAN
FOR PLANNING ONLY
(NOT FOR CONSTRUCTION)
L
E
W
5(48,5(''(7(17,21:,7+,17,(5$%& P³P³P³ P³
3529,'(''(7(17,21216,7(:,7+,17,(5$7,(5%7,(5& P³P³P³
727$/ P³
= 1552m² X 0.60m X 25% VOID RATIO = 232.80m³
= 450m² X 0.25m X 25% VOID RATIO = 28.13 m³
= 161.56m³