HomeMy WebLinkAboutCD-1-99 Zoning Compliance Summary Checklist - lots less than 557 sq metresBuilding Permit Number : ________________
PROPERTY INFORMATION
Address : ________________________________________ Y / N
Lot Depth : ____________Min. Basement El : ________ Y / N
Lot Width : ____________Prop. Basement El :________ Y / N
Lot Area : ____________ Y / N
Lot # : ____________ Y / N
Y / N
SETBACKS Stat. Right-of-Way : Y / N
Minimum Proposed Complies*
Principal Structure 5.5 metres m
8.0 metres m
1.2 metres m
Right Side 1.2 metres m
Flanking Street 3.0 metres m
* City of Maple Ridge use only
2.0 metres m
11.0 metres m
0.45 metres m
BP file # 0.45 metres m
4.5 metres m
m
m
m
m
Dwelling's Corner Grade Elevations
(metric)Left Right
Front finished gr.a) c) (lowest of existing or finished grade on Left side ))/ 2 = m
Rear finished gr.b) d) REAR DDP Avg CALCULATION (RDDP Avg) please see reverse
Front Existing gr.e) g)
Rear Existing gr.f) h) (lowest of existing or finished grade on Left side ))/ 2 = m
FRONT SLOPE CALCULATION (for negative gradient lots only as measured from Avg Curb Elevation to the Front Datum Determination Avg.)
Avg curb elevation (k) = m Horizontal length from Avg. Curb EL to the FDDP Avg (L) = m
Front DDP Avg ( i) = m Slope Calculation = ((k - i) / L) x 100 = __________ %
Qualifying for a height bonus (for dwelling only)? Y / N 10% or greater = 0.5m (1'-7.5") 15% or greater = 1.0m (3'-3.5")
BUILDING HEIGHT Roof pitch Maximum height permitted Bonus Proposed Complies
Principal Building m m
Detached Parking/Accessory structure m m
HIGHEST BUILDING FACE Maximum Proposed Complies
complies with sloping 7 m Highest Building Face line (from existing grades)7.0m m
complies with sloping 7 m Highest Building Face line (from finished grades)7.0m m
40% exemption rule applied? Y / N 40% %
RETAINING WALLS walls over 1.0 metre in height require P.Eng design Proposed Complies
RETAINING WALLS: maximum 1.20 m (4' - 0") height m
BUILDING COVERAGE Maximum %Proposed %
40%%m2
Detached Parking /accessory structures 15% %m2
Planchecker : __________________________ Date : ____________
City of Maple Ridge
11995 Haney Place, Maple Ridge, BC V2X 6A9 Tel: 604-467-7311 Fax: 604-467-7461
Inquires at: permits@mapleridge.ca Web site: www.mapleridge.ca
Min. setback to projections (bay windows, hutches, nooks, etc) from abutting interior side lot line 0.90m (3' - 0")
FRONT DDP Avg CALCULATION (FDDP Avg) please see reverse
Detached Garage / Carport /
Accessory structures
Flanking Street Side
DP30 Area :
lesser of 279m2 or 15% m2
11.0 metres
6.0 metres
Maximum area (in metric)
* 4.5 metres from a principal use measured from the
face of any chimney, bay window, hutch or nook
permitted elsewhere in this bylaw.
Stamp area (for City use only)
Revised Dec 2015
Front
COVENANTS REGISTERED ON TITLE:
m2
((Lowest of existing or finished grade on Right side) +
*Separation between structures
Proposed area (in metric)
Front Prop. Line
Comprehensive Design :
Geotechnical :
Flood Plain :Is this lot less than 557m2? Y / N
Left Side
Rear
Zoning Compliance Summary Checklist
Buildings & Structures for one Family Residential UseCD - 1 - 99
All buildings & Structures
Lane/Rear Prop. Line
Water Management :Plan: ____________________
Fish & Wildlife :
Maximum Roof projection into front, rear or exterior side yard setbacks 1.25m (4' - 1")
Maximum (detached accessory structure's) Roof projection into interior side yard and / or rear yard 0.3m (11.75'")
Interior Side Prop. Line
((Lowest of existing or finished grade on Right side) +
Maximum Roof projection into interior side yard 0.61m (2' - 0")
ONLY FOR LOTS LESS THAN 557m2 IN AREA
**Please be advised that this handout is a Zoning Bylaw summary only.
Please refer to the Zoning bylaw for complete information.**
BUILDING HEIGHT BASE LINEBUILDING HEIGHT BASE LINEBUILDING HEIGHT BASE LINEBUILDING HEIGHT BASE LINE - means:
I. averaging the two front Datum Determination Points on the lot; and
II. averaging the two rear Datum Determination Points on the lot; and
III. longitudinally extending a line joining (i) and (ii); illustrated by way
of the following diagram;
DATUM DETERMINATION POINTSDATUM DETERMINATION POINTSDATUM DETERMINATION POINTSDATUM DETERMINATION POINTS - means the two
points on a lot created where the front most and
rearmost wall face of the principal building, or
projections thereof, intersect with the outermost
sidewall faces, or projections thereof, measured
as the lesser of Natural or Finished Grade.
LOCALIZED DEPRESSIONLOCALIZED DEPRESSIONLOCALIZED DEPRESSIONLOCALIZED DEPRESSION - means:
I. an existing depression in Natural Grade not exceeding 3 metres (9.8ft.) in width, or the lesser of 3 metres or 20% of the wall length along any building wall that
it intersects;
II. a depression below Finished Grade created for the purposes of providing vehicles or pedestrian entrance to a building subject to the following conditions:
A. only one vehicle entrance and one pedestrian entrance are permitted as Localized Depressions on a single family residential building.
B. on any side of the building in a single family residential zone, the Localized Depression width shall not exceed the lesser of 50% of the corresponding
building width or:
* 6.0m (20 ft.) width for vehicle access.
* 2.44m (8 ft.) wide 3.0 m2 in area for a pedestrian access.
* 7.3m (24 ft.) wide for a combined vehicle and pedestrian access
III. any combination of vehicle or pedestrian entrances and existing depressions remaining after finish grading shall not exceed 50% of the corresponding building
width or length along any side of a building.
Highest Building Face Exemptions:Highest Building Face Exemptions:Highest Building Face Exemptions:Highest Building Face Exemptions:
I. 40% of the length of the building face can be exempt from this regulation. Different parts of the building face can be exempted, provided that the
sum of their lengths does not exceed 40% of the total length of the elevation.
II. 100% of the length of the rear building face for those lots whose entire rear lot line abuts land dedicated for park purposes by subdivision plan, within
which a watercourse shown on Schedule āEā exists, provided that the Highest Building Face is identified on the rear building elevation.
III. 100% of the length of the interior side building face for those lots whose entire interior side lot line abuts land dedicated for park purposes by
subdivision plan, within which a watercourse shown on Schedule āEā exists, provided that the Highest Building Face is identified on the interior side
building elevation.
IV. Roof eaves, decks, decorative features, and the pitched roof portion of either gable ends or dormers are exempt.
V. Any portion of the roof structure above the top plate is exempt from this calculation.