HomeMy WebLinkAboutSingle Family Dwelling New/Detached Garden Suite Application Checklist
New Single Family Dwelling / Detached Garden Suite
Application Checklist
For infill lots, confirm servicing requirements with
the city’s ENGINEERING DEPARTMENT PRIOR to applying for a building permit
Page 1 of 2
City of Maple Ridge Revised 2017-06-13
11995 Haney Place, Maple Ridge, BC V2X 6A9 Tel: 604-467-7311 Fax: 604-467-7461
Inspection Requests: inspectionrequests@mapleridge.ca Enquiries only at: buildingenquiries@mapleridge.ca
Date: Address: Zoning:
Single Family Dwelling Application Form filled out ……………….……………………………………………………………..
Accessory Building Application Form for Detached Garage (if applicable) ……………….……….…….. N/A
Zoning Compliance Summary Check List completed …………………….…………………………………………………..…..
Owner’s Acknowledgement of Responsibility (signed) …………………………………………………………………………….
Letter of Authorization for non-owner applicants ………..…………….……………………………………………………………
HPO Form……………………………………………… Yards document ………..………………………..…………
Letter from Engineer verifying Minimum Building Elevation (MBE) (for infill lots) ……....……………….…………..
Copy of Surveyed Lot Grading Plan……………………………………………….…………………………………………………..…..
Sealed Topographical Survey……………………………………………………….…………………………………………………..…..
Architectural plans – 2 copies, including rainscreen details ….……………………………………………………………….
Energy efficiency requirements (details & calculations)………………………………………………………………………….
Wildfire Development Permit Area (including details)….………………………………………………………….. N/A
Structural Plans – 2 copies (must have original seals from structural engineer) ….………………………………….
Retaining Walls shown including drainage .………………………………………………………………………………………….…
Schedule B plus wall design for retaining walls over 1.0 metre in height ……………………………………….………..
Solar conduit run and potential roof panel location to be shown on plans …………………………..……………..…..
Schedule B - Structural, plus certificate of insurance …………………………………………………………………..………..
Schedule B - Fire Suppression plus certificate of insurance ……………………………………………………………..……
Schedule B - Geo-tech (entire site), plus certificate of insurance & sealed site plan …………………………..…..
Geo-tech acknowledgement Sec. 219 Covenant letter – to be signed by BOTH Geo-tech and Structural
Engineers (Must include Land Title Registration Number & attached Geo tech Report date) …..... N/A
Appendix D for legislated landslide assessment (Bulletin 2012-02)…………………………………..……………………
Appendix J for flood hazard assessment …………………………………………………………………………..…...… N/A
Schedule B - Plumbing (infiltration system/rock pit/sani sump pump) plus cert of insurance ………….……..
Sealed design for infiltration/storm system/rock pit - siting to be shown on plan ……………………………………
Erosion & Sediment Control Schedule (Watercourse Bylaw) – (Requires Environmental Monitor & Builders
Signature) Schedule D Schedule E
Erosion & Sediment Control Plan …………………………………………………………………………………………………………
Septic Filing ………..……… Yes N/A Well Quantity ………………………………. Yes N/A
Covenants Req'd:
(In-fill lots will require infiltration covenants where other than a rock pit is being proposed for infiltration.)
Floodplain N/A Lower Hammond Floodplain N/A Infiltration N/A
Sanitary Sump Pump DGS & Parking N/A Fraser River Escarpment N/A
TRU/Secondary Suite N/A
PLEASE TURN PAGE OVER
New Single Family Dwelling / Detached Garden Suite
Application Checklist
Page 2 of 2
City of Maple Ridge Revised 2017-06-13
11995 Haney Place, Maple Ridge, BC V2X 6A9 Tel: 604-467-7311 Fax: 604-467-7461
Inspection Requests: inspectionrequests@mapleridge.ca Enquiries only at: buildingenquiries@mapleridge.ca
REQUIRED DOCUMENTATION & INFORMATION
*SITE PLAN
Scale = 1:100
(or 1/8” = 1-0”)
NOTE: Geodetic
elevations to be
in metric and are
to reflect the As-
Built lot grading
plan
Drawings scaled accurately
North Arrow, street name, street address shown
All setbacks shown
Basement, all floors including garage, u/s Truss & Ridge geodetic elevations
Minimum Basement Elevation (including lots on septic)
Front & Rear Datum determination Geodetic elevation
Natural & Finished geodetic grades around the building
Retaining walls including location, top and bottom elevations, and wall length
Retaining wall drainage (required for all walls)
Driveway & % slope, parking locations, access to entrance and rear yard
Streams and water wells to be shown and labelled
Septic disposal field location to be shown and labelled
Stairs, decks, window wells, projections
Floor areas and lot coverage summary
Infiltration System/Rockpits, R.O.W.’s and covenant boundaries
*Elevations
Scale = 1:50
(or ¼” = 1-0”)
Natural and finished geodetic grades
Building Grade Line, Datum Determination Points (DDP)
Basement, all floors including garage, u/s Truss & Ridge geodetic elevations
Dimension of raised heel trusses
Maximum Building Height Line shown
Highest Building Face Line shown
Spatial separation calculation shown
Fire rated assembly locations
Exterior cladding type (& Wild Fire DP)
Solar Panel location (South or West roof plane only)
*Floor Plans
Scale = 1:50
(or ¼” = 1-0”)
Structural framing indicated
Foundations layout
Unfinished basement dotted outline only for future layout
Section line shown
Room use and dimensions
Clear height under beams shown
Dimensions of doors, windows & stairs
Label guard & handrail heights and locations
Solar conduit location (on all floors)
*Section
Scale = 1:50
(or ¼” = 1-0”)
Full Cross Sections
Basement, all floors including garage, u/s Truss & Ridge geodetic elevations
Rooms labelled
Clear height under beams shown
Construction assemblies & rainscreen details (may be on separate sheet)
Energy efficiency requirements details & calculations(may be on separate sheet)