HomeMy WebLinkAboutPart 5.pdf2003 update of the Metering Specifications Added October 2015 Updated: October 2015 CITY OF MAPLE RIDGE DESIGN AND CONSTRUCTION DOCUMENTS PART 5 WATER METER MATERIAL SPECIFICATIONS & DESIGN GUIDELINES THIS PAGE INTENTIONALLY LEFT BLANK City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Contents 1 TABLE OF CONTENTS Page 1. INTRODUCTION ........................................................... ..................................................................................... 1 1.1 Preamble .................................................................................................. ................................................ 1 1.2 Content and Intent ............................................................................................................................. ...... 1 1.3 Definitions ................................................................................................................................................ 1 1.4 Responsibilities ........................................................................................................................................ 2 2. MATERIAL SPECIFICATIONS ................................ ............................................................................................. 3 2.1 Water Meters....................................................................................... ..................................................... 3 2.2 Registers.................................................................................................................................. ................. 3 2.3 Remote Receptacles................................................................................................................................ 4 2.4 Valves................ ........................................................................................................................................ 4 2.5 Pipe and Fittings ...................................... ................................................................................................ 5 2.6 Flange Adapters ................................................................................ ....................................................... 5 2.7 Bolts and Nuts........................................................................................................................... ............... 5 2.8 Strainers ................................................................................................................................................... 5 2.9 Double Check Valve Assembly ................................................................................................................. 5 2.10 Meter Chambers .............................. ........................................................................................................ 6 3. DESIGN AND INSTALLATION GUIDELINES....................................................... ................................................ 7 3.1 Meter Sizing.................................................................................................................................... .......... 7 3.2 Meter Selection ........................................................................................................................................ 8 3.3 Meter Location ......................................................................................................................................... 8 3.4 Meter Configuration ......................... ........................................................................................................ 9 3.5 Applicant Submissions................................................................... ........................................................ 11 3.6 Sample Meter Installation Drawings..................................................................................................... . 12 Appendix A Water Meter Sizing Calculation Sheet Appendix B Sample Meter Installation Drawings THIS PAGE INTENTIONALLY LEFT BLANK City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 1 1. INTRODUCTION 1.1 Preamble This document outlines the City’s requirements for the installation of cold-water meters on municipal water services, pursuant to Council Policy. 1.2 Content and Intent This document is divided into four separate parts: Introduction – which outlines the purpose of this document, defines key terms, and outlines the responsibilities of each party. Material Specifications – which are intended to provide direction to the Applicant and Applicant’s Engineer regarding approved products, materials, and other specifications that must be incorporated into the design of the new water service and water meter. Design Guidelines – which are intended to provide direction to the Applicant and Applicant’s Engineer on the elements that need to be considered in the design of new water meter installations. Appendices – which provide reference material including a water meter sizing calculation sheet and sample water meter installation drawings. 1.3 Definitions Applicant means a property Owner or their authorized agent including the developer of the property or the builder of premises on the property, who makes an application for a water service connection or a reconnection to an existing water service. Applicant’s Engineer means a professional engineer engaged by the Applicant to design the water service connection and water meter. ASTM stands for the American Society for Testing and Materials. AWWA stands for the American Water Works Association. City refers to the City of Maple Ridge. CSA stands for the Canadian Standards Association. FM stands for Factory Mutual. NFPA stands for National Fire Protection Association. Owner with respect to real-estate, has the same meaning as defined in the British Columbia Community Charter. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 2 ULC stands for Underwriters Laboratory of Canada. 1.4 Responsibilities The City of Maple Ridge By-Law No. 6002-2001 outlines metering requirements for specific property types and land uses. The Applicant or Applicant’s Engineer is responsible for determination of the appropriate size and type of water meter as well as the design of the complete meter installation. The water meter design must be reviewed and accepted by the City prior to initiation of any on-site works associated with the water meter installation. For all new water services where the meter is located on private property, the Applicant is responsible for the supply and installation of the meter and all associated components. Metering requirements and designs for all water services intended for fire-fighting uses (dedicated fire lines and combined domestic/fire lines) shall be reviewed and accepted by the City. The Applicant is responsible for the supply and installation of the meter and all associated components for all fire service installations. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 3 2. MATERIAL SPECIFICATIONS 2.1 Water Meters 2.1.1 The following meters are acceptable for use in the City: Table 1 – Accepted Water Meters Manufacturer Model Type Neptune T-10 Positive Displacement TRU/FLO Compound HP Protectus III Fire Service Sensus SR II Positive Displacement OMNI C2 Compound OMNI F2 Fire Service For specific circumstances involving irrigation or bulk water supply, the City may accept the use of a turbine meter. 2.1.2 Water meters shall meet the following AWWA standards:  Positive displacement meters must conform to AWWA C700.  Turbine meters must conform to AWWA C701.  Compound meters must conform to AWWA C702.  Fire service meters must conform to AWWA C703. 2.1.3 For all meters with base plates, the base plate shall be cast iron for outside installations and bronze for inside installations. Plastic base plates are not acceptable. 2.1.4 All 38mm and 50mm diameter meters shall have oval two-bolt flanges. 2.1.5 All meters must be new. Used or refurbished meters are not acceptable. 2.2 Registers 2.2.1 Registers shall be absolute encoder-type remote-registration conforming to AWWA C707. Registers utilizing generator pulses, low voltage conversions, or with internal battery power are not accepted by the City. Power necessary for data transmission must be supplied by an interrogation device. Registers must be compatible with Neptune walk-by, mobile, and R900 Gateway interrogation systems. 2.2.2 The register must provide at least six-digit visual registration at the meter with the capability to simultaneously encode (in digital format) at least six-digits of the meter reading for transmission through the remotely located receptacle. Each reading encoded electronically must include the meter identification number and record the read to the nearest cubic metre (m3). 2.2.3 Registers must have visual display capabilities for leak detection by means of a full test sweep hand/dial or an electronic flow indicating display. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 4 2.2.4 Registers utilizing number wheels must be provided with spring type or magnetic sensing type contacts to ensure a high probability of data transmission. 2.2.5 All registers must be programmed with a multiplier of 1.0 and shall record measurement units in cubic metres (m3). The unit of measurement, month and year of manufacture, and other identification information must be clearly printed on the face of the register. 2.2.6 All registers must be factory sealed to prevent tampering and to provide protection for internal components suitable for operation in humid or submerged conditions. Registers must be removable from the meter without disassembling the meter body, and must permit field installation or removal without taking the meter out of service. 2.2.7 All registers for meters 75mm diameter and larger must have data logging capabilities and able to store a minimum of 35 days of hourly data. Battery life must be guaranteed for a minimum of 10 years. 2.2.8 Registers must be new. Used or refurbished registers are not acceptable. 2.3 Remote Receptacles 2.3.1 Neptune E-Coder R900i radios shall be installed for all Neptune meter installations and Neptune R900 MIU radios shall be installed for all Sensus meter installations. 2.3.2 Remote receptacles must be either wall mount or pit mount style. Remote receptacles must not include a remote display or data storage. 2.3.3 The materials employed must be resistant to corrosion, ultraviolet degradation, rain, condensation, and suitable for rugged service for the duration of their expected life. 2.3.4 The unit must provide for mechanical and electrical connection between the receptacle and interrogation equipment. Interrogation must be achieved by inductive coupling without physical connection of the reading device. 2.3.5 Colour coded (red, green, black), 22 gauge, three-wire terminals must be provided. Excess wire must be looped and fastened to the building wall or chamber lid. 2.3.6 For wall mounted receptacles, the receptacle shall be sealed with the terminal screws concealed by the receptacle. 2.3.7 The receptacle construction must incorporate the function of a cable clamp or strain relief coupling. 2.3.8 The receptacle shall be mounted such that it is free and accessible by the meter reader or City staff. 2.4 Valves 2.4.1 Valves up to 50mm diameter must meet AWWA C800 and must have bronze case with National Pipe Threaded (NPT), soldered, compression type, or flange connections. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 5 Valves may be ball or cylinder type using rubber o-ring seals. Activation shall be via curb-stop style operating nut. 2.4.2 All bypass valves must be equipped with a lock wing on both the operating nut and case. 2.4.3 Valves over 50mm diameter must be ductile iron, resilient seat, with non-rising stem (NRS), gate valves with flanged ends and must meet AWWA C509. Stem seal to be oring type. For valves accessible from the surface, activation shall be via standard 50mm square operating nut. For valves that are inaccessible from the surface (located within a chamber) shall be activated via hand wheel. In all possible and appropriate instances, a Maple Ridge style valve box must be installed over buried valves. 2.4.4 All valves on fire service lines must comply with NFPA and British Columbia Fire Code requirements. 2.5 Pipe and Fittings 2.5.1 All water service connections 75mm diameter or larger must be restrained to the City watermain. 2.5.2 All pipes, pipe fittings, and jointing methods for installation of meters 100mm diameter or larger shall comply with the latest stipulations within the City’s Design Criteria Manual and Supplementary Specifications. 2.5.3 All pipes, pipe fittings, and jointing methods for installation of meters 75mm diameter or smaller shall comply with the latest requirements of the British Columbia Plumbing Code and AWWA standards. 2.6 Flange Adapters 2.6.1 Flange adapters for sizes 38mm to 200mm diameter shall conform to AWWA C219. 2.7 Bolts and Nuts 2.7.1 Bolts and nuts shall be stainless steel. Bolts shall conform to ASTM F599 or ASTM F731. Heavy hex nuts shall conform to ASTM F574 or ASTM F836. Threads, fit, and dimension must conform to AWWA C111. 2.8 Strainers 2.8.1 Strainers must be straight type and of the same size as the meter. 2.8.2 Strainer mesh material shall be corrosion resistant (such as stainless steel). 2.9 Double Check Valve Assembly 2.9.1 Backflow prevention devices shall be as per the City of Maple Ridge By-Law No. 6002-2001. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 6 2.10 Meter Chambers 2.10.1 Below-grade meter boxes and vaults shall be pre-cast concrete. The only exception is for installations with #37 meter boxes where the upper sections shall be cast iron as indicated on the Sample Meter Installation Drawings. 2.10.2 Lids must be capable of withstanding H-20 dynamic loading in travelled surfaces and H-20 static loading in all other areas. Lids must have two pre-drilled 45mm diameter holes to facilitate mounting of a remote receptacle. These holes must remain plugged until the receptacle is installed. 2.10.3 Lids shall be cast iron or steel checker plate for meter boxes and aluminum or galvanized steel, spring assisted hatches for meter vaults. Manhole type lids are not acceptable. 2.10.4 Access lids, latches, and ladders must comply with the most current WorkSafeBC requirements. 2.10.5 All chambers must be damp-proofed by applying grout and a black and white asphalt emulsion coating to all exterior surfaces. Construction joints must be made water-tight with an appropriate water-stop sealant. All pipe penetrations through the chamber must be sealed using grommets or link seals. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 7 3. DESIGN AND INSTALLATION GUIDELINES 3.1 Meter Sizing For all existing single family residential homes without fire sprinklers, the water meter size shall be 19mm diameter, unless the Applicant’s Engineer can demonstrate the need for a larger meter. In all other cases, the meter shall be sized in accordance with AWWA Manual of Water Supply Practices M22 Sizing Water Service Lines and Meters taking into account specific requirements outlined in the meter sizing calculation sheet included in Appendix A. To be clear, this sizing methodology is based on the AWWA fixture value method, and not the fixture unit method employed in the BC Building Code for piping within buildings. The maximum operating range for a water meter shall not be greater than 90% of the maximum instantaneous flow capacity as outlined by the manufacturer, with a maximum pressure loss of 48 kPa (7 psi) at the design flow rate. The meter size selection should not compromise the operating range or the long term life of the meter and must ensure that pressures supplied to the property are appropriate for the intended use. In this same regard, the analysis should be sufficiently thorough to avoid unnecessarily over-sizing the meter. In some instances, this may result in a smaller meter than the water service size. Table 2 is provided as a guide for various meter types and sizes for a range of uses and flows. The values presented in this table are based on AWWA standards and do not necessarily reflect manufacturer data. Accordingly, the Applicant’s Engineer shall confirm that the manufacturer’s performance data for the recommended meter size and type satisfies the design requirements for the given application. Table 2 – Meter Selection Guide Water Use Land Use Meter Size (mm) Meter Type Flow Rates (L/s) Operating Range Normal Continuous Flow Maximum Flow Domestic Residential Industrial Commercial Institutional 16 PD 0.016 – 1.26 0.63 1.26 19 PD 0.032 – 1.89 0.95 1.89 25 PD 0.047 – 3.15 1.58 3.15 38 PD 0.095 – 6.31 3.15 6.31 50 PD 0.126 – 10.09 5.05 10.09 50 Compound 0.016 – 10.09 5.05 10.09 75 Compound 0.032 – 20.19 10.09 20.19 100 Compound 0.047 – 31.55 15.77 31.55 150 Compound 0.095 – 63.09 31.55 63.09 Irrigation Bulk Water Supply Agricultural Golf Courses Parks Industrial 38 Turbine 0.25 – 7.57 5.05 7.57 50 Turbine 0.25 – 10.09 6.31 10.09 75 Turbine 0.50 – 22.08 15.14 22.08 100 Turbine 0.95 – 39.75 26.50 39.75 150 Turbine 1.89 – 88.32 58.04 88.32 200 Turbine 3.15 – 151.42 100.95 151.42 Fire service meters shall be sized based on Fire Underwriters Survey requirements for on-site hydrants and NFPA standards for sprinkler systems. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 8 3.2 Meter Selection Domestic Services Water meters that are accepted by the City are listed in Table 1 of Section 2.1.1. Meter selection requirements regarding sizing are discussed in Section 3.1. Unless accepted by the City, a single domestic meter is to be installed per property. The only exception is duplex units where two separate domestic meters are to be installed. Dedicated Fire Services With the exception of single family and duplex dwellings, all dedicated fire services must be equipped with a FM approved/ULC listed double check detector valve assembly to detect unauthorized water use. The receptacle for the tattle tale meter must be mounted such that it is accessible for the meter reader and City staff. A weather-resistant tag indicating “Tattle Tale Meter” must be attached to the receptacle. All double check detector valve assemblies shall be factory supplied and installed as a complete unit. Combined Fire/Domestic Services Where the Applicant proposes a combined fire and domestic service, a FM approved/ULC listed water meter and backflow prevention device assembly shall be installed. Fire service meters that are reviewed and accepted by the City are listed in Table 1 of Section 2.1.1. 3.3 Meter Location Unless otherwise accepted by the City, all meters shall be installed outside in a box or vault adjacent to the property line. For single family detached homes, the meter box shall be located within the City right-of-way, 300mm from the property line. For all other cases, the meter box/chamber shall be located within private property, 300mm from the property line. If the City watermain is within a right-ofway on private property, the meter box/chamber should be located outside of the right-of-way. For all outside meter installations, an area of at least 1 metre horizontal and 2 metres vertical around the meter box/chamber must be free of major landscaping or obstructions to provide access for City staff. Whenever possible, locating meter boxes/chambers within driveways or parking areas should be avoided. If an inside meter installation is approved, the meter must be located such that is accessible for maintenance, reading, and inspection by City staff. Meters installed in a utility room, or elsewhere inside a building, shall be within reasonable distance of a floor drain. Meters are not to be installed in bedrooms or bathrooms. An area of at least 1 metre horizontal and 2 metres vertical from the meter shall remain free of obstruction to provide access for City staff. No electronic, electrical, mechanical, or other water sensitive equipment or machinery should be placed or installed under the meter installation, or in an area where splash or flow from the meter assembly could occur during servicing of the meter. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 9 3.4 Meter Configuration Meters shall be installed horizontally with register faces oriented vertically. Straight pipe lengths upstream and downstream of the meter (including the presence of bypass tees, isolation valves, reducers, and any other fittings) shall comply with manufacturer’s recommendations for optimal meter accuracy. Meters, strainers, valves, bypasses and associated piping or fittings shall be supported by appropriate steel pipe stands. For all meters 50mm diameter or larger, except when installed on a setter, a coupling must be installed on the downstream side of the meter to provide flexibility if the meter needs to be removed. Table 3 below summarizes general installation components of various meter types and sizes. This table is not inclusive of all elements that need to be considered to satisfy the City’s metering requirements. It is provided solely for reference. Table 3 – Meter Installation Guide Meter Size (mm) Meter Type Bypass Required Strainer Required Setter Required 16 PD No No Yes 19 PD No No Yes 25 PD No No Yes 38 PD Yes No Yes 50 PD Yes No Yes 50 Compound Yes Yes * 75 Compound Yes Yes No 100 Compound Yes Yes No 150 Compound Yes Yes No 200 Compound Yes Yes No * Setter installation acceptable for 50mm Sensus OMNI C2 meters. 3.4.1. Isolation Valves Isolation valves must be provided upstream and downstream of the meter assembly to facilitate the removal of the water meter and strainer. Valves shall comply with the requirements stated in Section 2.4. Isolation valves shall be located inside the chamber and operated by a handwheel. 3.4.2. Bypasses Bypasses are to be installed as indicated in Table 3. For domestic services, the bypass shall be no less than half the size of the meter setter or service connection. For fire services, a full size bypass shall be provided. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 10 As per Section 2.4.2, all bypass valves must be equipped with a lock wing on both the operating nut and case. After testing the installation, the bypass valve shall be closed and sealed by the installer. 3.4.3. Setters All positive displacement meters located in exterior meter boxes shall be installed on a setter. Re-setters shall only be installed when approved by the City. 38mm and 50mm diameter Sensus OMNI C2 meters may be installed on a setter, provided that the setter is equipped with a high bypass and flanged inlet/outlet connections. All setters shall include full port inlet ball valves. 3.4.4. Strainers Where required, as stated in Table 3, strainers shall be installed immediately upstream of the meter using flanged connections. For meters not supplied inclusive of a strainer, the strainer shall be installed as per manufacturer’s specifications. Sufficient area must be provided within the chamber to drain, inspect, and clean the strainer. 3.4.5. Test Ports Test ports must be provided for all meters 50mm and larger in diameter. In the absence of a test port on the meter case, a test tee must be installed with a 50mm threaded lateral and plug at a distance of three pipe diameters downstream of the meter. 3.4.6. Chambers The Applicant is responsible for selecting the appropriate chamber for a given application that satisfies the City’s requirements, including specifications noted in Section 2.10. Chamber lids/hatches shall be large enough to facilitate service or replacement of the complete meter assembly including the meter, strainer, and isolation valves. The minimum distance between the inside chamber walls and outside edges of pipe shall be 300mm to provide sufficient space for maintenance. At least 600mm separation shall be provided between the water service line and bypass. All below-grade chambers shall include a drain connected to the City’s stormwater collection system. Where a gravity connection is not available, the City may accept a hydraulic eductor assembly or electric sump pump. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 11 3.4.7. Receptacles/Radios For outside meters installed at the property line, remote register receptacles must be mounted to the meter box/chamber lid according to the manufacturer’s instructions. Receptacles must be provided with at least 1.8 metres of 22 gauge, three-colour (red, green, black) wire connected and sealed at the receptacle without terminal exposure. Remote wiring connections must be either factory or field sealed to ensure that the connection is waterproof. Wall mounted remote receptacles must be mounted approximately 1.2 metres above-grade and easily accessible for reading. The wire from the meter to the receptacle must be installed in accordance with the manufacturer’s instructions and must not exceed 30 metres in length. The cable must run neatly in horizontal or vertical directions only, in an approved casing or duct. Buried casings or ducts should be at least 600mm deep. Any penetrations through the building wall to facilitate remote receptacle mounting shall be sealed with sealing compound. Compound meters with two registers must have a separate remote receptacle mounted to the box/chamber lid or wall for each register. 3.5 Applicant Submissions An Applicant’s submission of an Application for Water Service to the City shall include sufficient detail to support the proposed water meter installation including:  Size of the water service connection;  Meter size supported by water demand calculations as per Appendix A for all meters 50mm diameter or larger;  Meter type, manufacturer, and model;  Meter location relevant to property line and building footprint depicted on a site plan (1:500 scale);  Meter chamber layout depicted on a detail drawing (1:250 scale);  Discharge location for chamber drain;  Land use(s);  Presence of on-site fire hydrants or fire sprinklers;  Presence of irrigation systems;  Future development phases for the property; and  Any other relevant information regarding the proposed meter installation. For all meters 50mm diameter or larger, the Applicant must submit drawings and calculations sealed by the Applicant’s Engineer to support the proposed meter size, type, configuration, and installation plan. Submissions not in substantial conformity to the City Water Meter Material Specifications & Design Guidelines and the BC Plumbing Code will be rejected by the City. The Applicant shall not proceed with the water meter installation without the prior acceptance of the City. City of Maple Ridge Water Meter Material Specifications & Design Guidelines February 2015 Page 12 3.6 Sample Meter Installation Drawings Sample meter installation drawings are provided in Appendix B. These drawings are provided as a guide for the Applicant and Applicant’s Engineer and are intended to illustrate some of the common meter installation scenarios in the City. The Applicant and Applicant’s Engineer are responsible for the property specific water meter design. CITY OF MAPLE RIDGE Appendix A ENGINEERING DEPARTMENT WATER METER MATERIAL SPECIFICATIONS & DESIGN GUIDELINES VERSION: FEBRUARY 2015 APPENDIX A Water Meter Sizing Calculation Sheet CITY OF MAPLE RIDGE Appendix A ENGINEERING DEPARTMENT WATER METER MATERIAL SPECIFICATIONS & DESIGN GUIDELINES VERSION: FEBRUARY 2015 THIS PAGE INTENTIALLY LEFT BLANK Water Meter Sizing Calculation Sheet AWWA M22 Fixture Value Methodology General Information Customer Name Address PID Number Occupancy Type: Multifamily Institutional Commercial Industrial Agricultural Other Step 1: Calculate Customer Total Fixture Value Fixture AWWA Fixture Value (GPM @60 psi) No. of Fixtures Fixture Value Bathtub 8 x = Bedpan Washers 10 x = Bidet 2 x = Dental Unit 2 x = Dishwasher 2 x = Drinking Fountain -Public 2 x = Hose Bibs (c/w 50 ft wash down): -1/2 inch 5 x = -5/8 inch 9 x = -3/4 inch 12 x = Kitchen Sink 2.2 x = Lavatory 1.5 x = Showerhead (Shower only) 2.5 x = Service Sink 4 x = Toilet: -Flush Valve 35 x = -Tank Type 4 x = Urinal: -Pedestal Flush Valve 35 x = -Wall Flush Valve 16 x = Wash Sink (Each Set of Faucets) 4 x = Washing Machine 6 x = Other: x = x = x = Combined Fixture Value Total = GPM (A) Step 2: Calculate Customer Probable Peak Demand Refer to Figure 4-2 or 4-3 Customer Peak Demand = GPM (B) 1 Step 3: Apply Pressure Adjustment Factor City water system pressure = psi Pressure factor from Table 4-1 = (C) Customer Adjusted Peak Demand (B x C) = GPM (D) Step 4: Calculate Irrigation Demand Underground Sprinklers: No. of Sections * -Spray System 1.16 x = -Rotary System 0.4 x = * 100 ft2 Irrigation Area = 1 Section Total Irrigation Demand = GPM (E) Step 5: Calculate Total Peak Fixed Demand % at Peak Demand Domestic Demand from Step 3 (D) x = Irrigation Demand from Step 4 (E) x = Total Peak Fixed Demand = GPM (F) Step 6: Select Water Meter Water Meter Make /Model: = Water Meter Size * = inches Water Service Connection Size = incles Meter Location (outside /inside) = * Total Peak Fixed Demand (F) not to exceed 90% of Meter Rated Peak Instantaneous Flow * Pressure Loss at Total Peak Fixed Demand (F) not to exceed 7 psi Professional Certification (Applicant's Engineer ) Name: Company: Date: Comments: 2 CITY OF MAPLE RIDGE Appendix B ENGINEERING DEPARTMENT WATER METER MATERIAL SPECIFICATIONS & DESIGN GUIDELINES VERSION: FEBRUARY 2015 APPENDIX B Supplementary Standard Detail Drawings -Water Meter Installation CITY OF MAPLE RIDGE Appendix B ENGINEERING DEPARTMENT WATER METER MATERIAL SPECIFICATIONS & DESIGN GUIDELINES VERSION: FEBRUARY 2015 THIS PAGE INTENTIALLY LEFT BLANK